Dampers & Vane Materials
RETROFIT DAMPER FIRE DAMPERS & ACCESS DOORS
The Aprilaire Retrofit Zoned Comfort DamperAprilaire provides the solution for economically zoning existing homes. Installed through a simple cut-out in the side of a 6” branch duct, this damper provides speedy installation and operates with standard 24 volt zone panels, minimizing system cost. The damper benefits from a proven “no gears” design and is installed with traditional sheet metal tools, wires and fittings so no special training or tools are required. And, the damper features an LED which lights to indicate when the damper is closed, simplifying checkout.
CAT. NO. 5H492
MFG. NO. DESCRIPTION EACH 6706
Retrofit Damper $86.17 DAMPER POWER DISTRIBUTION PANEL
Fire dampers are typically intended to be used as part of the HVAC duct system when passing through a fire-rated barrier (walls, partitions or floors). Fire dampers will close automatically when a temperature sensitive, fusible link detects elevated temperatures and opens. There are two categories of fire dampers.
The first are static fire dampers which close when the HVAC system blower is not running (probably turned off by means of an automatic fire detector). The second are dynamic fire dampers, which close while the HVAC system blower is running. Dynamic fire dampers are investigated for closure under maximum recom- mended airflow.
All installed fire dampers must be accessible for inspection and/or testing by the local authorities. If fire dampers are not accessible from a grill or register, an access door in the ductwork is required.
Fire dampers are typically used in commercial and institutional buildings such as:
• Motels • Hospitals • Clinics
• Restaurants
• Senior Citizen Complexes • Nursing Homes
• Assisted Living Facilities • Retail Stores • Apartments • Schools • Churches • Offices
Metal-Fab fire dampers & access doors are not stocked at R.E. Michel locations but are available as a special order item. Please contact your local branch or sales representative for more information.
The Model 8028 helps simplify the wiring process when control- ling more dampers then the zone control panel can handle, isolat- ing the dampers for the control circuit eliminating over-current issues.
CAT. NO. 5H494
MFG. NO. DESCRIPTION 8028
Damper Power Distribution Panel
EACH $94.83
PRE-ASSEMBLED DAMPERS
Malco dampers are designed for forced air systems, they are not capable of being used in wood, coal or other similar systems.
CAT. NO. 8H776M
MFG. NO. DESCRIPTION D6AS
8H776MA D8AS
Damper - 6” diameter Damper - 8” diameter
EACH $2.44 $2.97
AIR TURNING VANES
The most convenient system for constructing turning vanes for any size metal or fiberglass duct. 2” radius single blade vanes are shipped in 10 ft. lengths; 24 gauge pre-punched vane rail comes in 100 ft. roll.
Both vane and rail are cut to desired size and assembled with no tabs or grooves to cut, no special tools. Mount to metal duct with sheet metal screws, or to fiberglass with shoulder screws and plates shown on this page.
CAT. NO. MFG. NO. 8H878 8H879
RA-V2G
8H8800 8H8801
RA-IVR-3G RAHTV400G
DESCRIPTION
Turning Vane, 10 ft. length Mounting Rail, 100 ft. roll
4” Galvanized Turning Vane (Ctn. of 150’) RAHTV4GRA 4” Galvanized Push-On Rail (Ctn. of 150’)
EACH $13.07
$161.67 $291.44 $169.30
946