DIRECT VENT, HIGH EFFICIENCY OIL FIRED FURNACES ON HEAT EXCHANGER ON PARTS
Oil Furnace “Through-The-Wall” venting without the use of a power venter. Through-the-wall vent- ing is a top quality, high efficiency method of releasing combustion products to the outdoors through a vent on the side of the house, rather than a traditional chimney. Much like a dryer’s venting system, this method utilizes the burner to efficiently force the combustion products from the heating equipment. Olsen Direct Sidewall Vent is the perfect solution when a conventional chimney just won’t do. All furnaces supplied with high efficiency AFII Beckett Burners. Direct Sidewall Vent is available on these models of Olsen Oil Furnaces. Because the need for a chimney is eliminated, the losses traditionally associated with a chimney are also eliminated. This allows for an overall increase in installed appliance efficiency. The Olsen Direct Sidewall Vent kit has been designed for flexibility in installation. Kits are available in 4” (BCL/BFL) and 3” (BML/HML/WML) diameter outlets and in 10’, 15’ and 20’ lengths. Every Direct Sidewall Vent installation requires Olsen Vent Termi- nal in addition to the venting kit. Only one wall opening is required for co-axial vent intake/combustion unit. The Olsen Vent Terminal utilizes a two-pipe combustion air/exhaust gas configuration. Indoor air is never used for combustion thereby ensuring greater efficiency and safety in new, tightly sealed houses. The burner provides the necessary pressure for adequate venting of flue products - no additional motors or controls are required. Combustion air piping and vacuum relief valve are to be field supplied.
CAT. NO. MFG. NO.
3H655 3H655 3H655 3H656 3H656 3H656 3H657 3H657 3H657 3H657 3H658 3H658 3H658 3H658 3H659 3H659 3H659
HML 80 B2U BML 80 BB2U BCL 100 B2U FURNACE TYPE Highboy
CAPACITY BTUH OUTPUT 63,000 75,000 86,000
Lowboy/Rear Flue
Mini-Lowboy, Rear Flue * 59,500 76,500 87,000 75,000 86,000
BFL 100 B2U Lowboy/Front Flue
101,000 117,000 75,000 86,000
101,000 117,000
WHML 80C B2U Counterflow/Horizontal * 58,000 75,000 85,000
* Exposed Burner MFG. NO. HML 80 B2U
VOLTAGE MAX. FUSE AMPS DIMENSIONS H x W x D DUCT CONNECTIONS SUPPLY
115
BML 80 BB2U 115 BCL 100 B2U BFL 100 B2U
115 115
WHML 80C B2U 115
15 15 15 15 15
49-5/8 x 22 x 31” 32 x 22 x 51-1/2” 41 x 22 x 51-1/2” 41 x 22 x 51-1/2”
55-1/4 x 22 x 22-1/8” 20-1/2 x 20”
20-1/2 x 18-1/2” 20-1/2 x 18-5/8” 20-1/2 x 18-5/8” 19 x 19”
All Direct vent units require the use of a specific vent kit and termination shown below VENT SIZE VENT
DUCT CONNECTIONS RETURN 14 x 22”
20-1/2 x 19”
20-1/2 x 18-5/8” 20-1/2 x 18-5/8” 18 x 18”
3” 3” 4” 4” 3”
CONNECTION 5” 5” 6” 6” 5”
A.F.U.E.% FLOW RATE
83.0 82.0 81.0 83.0 82.0 81.0 84.1 84.1 83.1 83.4 84.1 84.1 83.1 83.4 83.0 82.4 81.5
0.55 gph 0.65 gph 0.75 gph 0.55 gph 0.65 gph 0.75 gph 0.65 gph 0.75 gph 0.85 gph 1.00 gph 0.65 gph 0.75 gph 0.85 gph 1.00 gph 0.50 gph 0.65 gph 0.75 gph
CFM @ .50” E.S.P. 1476
1346 1585
FLUE LOCATION Front
Rear Rear
BLOWER MOTOR H/P 1/2
1/2 1/2
BLOWER MOTOR SPEEDS 4
4 4 EACH 1585 Front 1/2 4 1291 Front 1/2 4
$3,270.37 $3,270.37 $3,270.37 $3,219.27 $3,219.27 $3,219.27 $3,404.82 $3,404.82 $3,404.82 $3,404.82 $3,609.21 $3,609.21 $3,609.21 $3,609.21 $3,848.59 $3,848.59 $3,848.59
WEIGHT
200 240 280 280 265
ACCESSORIES FOR DIRECT VENT OIL FURNACES CAT. NO. MFG. NO.
(Required for all installations) DESCRIPTION
3H660Z 3H660G 240006906
3H660AZ 240006907 3H660BZ 24006908 3H660CZ 240006909 3H660DZ 240006910 3H660EZ 240006911 3H660F
28972 3H660G 29231
Vent Kit, 3” x 10 ft.- HML, BML, WML Vent Kit, 3” x 15 ft.- HML, BML, WML Vent Kit, 3” x 20 ft.- HML, BML, WML Vent Kit, 4” x 10 ft.- BCL, BFL Vent Kit, 4” x 15 ft.- BCL, BFL Vent Kit, 4” x 20 ft.- BCL, BFL Concentric Intake/Vent Terminal 33” Riser Intake/Vent Terminal
EACH
$448.74 $585.11
$1,366.80 $1,033.86 $1,363.94 $803.46 $598.77
$1,212.54
3H660F