MULTI-POSITION BLOWER/COIL UNITS
“R” series air handlers are sturdy built, wrap around design for low air leakage (less than 2%) with two front mounted service panels. The Hydrotec drain pans are treated with an anti-microbial additive to resist mold and mildew growth and improve indoor air quality. Suitable for use with R-22 and R410A. Two speed blowers and built in, bottom filter racks. Blower coils come with additional drain pan installed for upflow, horizontal left or horizontal right applications. Electrical connections can be made on top, right or left side. Dual drain connections (3/4”) on left and right. Refrigerant con- nections are 3/8” and 3/4” od up thru 2 ton, 2-1/2 thru 5 ton are 3/8” and 7/8” od. All air handlers are 230v-1 ph
CAT. NO. MFG. NO.
3A300 3A301 3A302 3A303 3A304 3A305 3A306 3A307 3A308
RCM Series • 1-1/2 thru 5 ton Cooling
ON PARTS
RCME34218S 1/4 RCME34224S 1/4 RCME36230S 1/4 RCME36236S 1/3 RCMCC6242S 1/3 RCMDD2242S 1/3 RCMDD2248S 1/2 RCMDD1260S 1/2 RCMDD4560S 1/2
BLOWER MOTOR H/P CFM @ 5” E.S.P. DIMENSIONS H x W x D DUCT CONNECTIONS SUPPLY W x D 16-1/2” x 17” 16-1/2” x 17” 19-1/4” x 17” 19-1/4” x 17” 19-1/4” x 21” 19-1/4” x 21” 19-1/4” x 21” 19-1/4” x 21” 19-1/4” x 21”
600 800
1000 1200 1400 1400 1600 1850 1850
46-3/4 x 18-1/2 x 22” 46-3/4 x 18-1/2 x 22” 51 x 21-1/4 x 22” 51 x 21-1/4 x 22” 54 x 21-1/4 x 26” 54 x 21-1/4 x 26” 54 x 21-1/4 x 26” 60 x 21-1/4 x 26” 60 x 21-1/4 x 26”
DUCT CONNECTIONS RETURN W x D 13-1/2” x 18-1/4” 13-1/2” x 18-1/4” 16-1/4” x 22-1/4” 16-1/4” x 22-1/4” 16-1/4” x 22-1/4” 16-1/4” x 22-1/4” 16-1/4” x 22-1/4” 16-1/4” x 22-1/4” 16-1/4” x 22-1/4”
ACCESSORIES FOR RCM SERIES UNITS
ELECTRIC HEATERS FOR RCM SERIES UNITS
CAT. NO. MFG. NO. DESCRIPTION USE WITH: 3A070 3A071 3A072 3A074
655009-01 5 kw Heater 655009-05 7.5 kw Heater 655009-06 10 kw Heater 655009-09 15 kw Heater
3A082R
655009-11 20 kw Heater with breaker
EACH
All 1-1/2 thru 5 ton RCM $102.42 All 1-1/2 thru 5 ton RCM $122.51 All 1-1/2 thru 5 ton RCM $139.17 $237.14
All 2-1/2 thru 5 ton RCM (Max KW for 1-1/2 - 2 ton)
4 & 5 ton RCM (Max KW for 2-1/2 - 3-1/2 ton)
$281.10
CAT. NO. MFG. NO. DESCRIPTION 10H1099 LB62009C Single point Power kit 3A139
EACH $221.10 65873175 Counterflow Conversion kit $63.43
CIRCUIT BREAKERS FOR RCM SERIES UNITS
CAT. NO. MFG. NO. DESCRIPTION 3A085 3A086 3A087
110000183 5 kw Circuit Breaker 110000226 7.5 kw Circuit Breaker 110000184 10 kw Circuit Breaker
EACH $63.07 $64.38 $65.40
3A085A 110000247 Mounting Bracket for 3A085, 3A086 & 3A087 $15.99 Note: 15 kw & 20 kw heaters come with breakers mounted.
WEIGHT EACH
129 lbs 131 lbs 138 lbs 148 lbs 172 lbs 172 lbs 177 lbs 190 lbs 190 lbs
$1,357.48 $1,371.00 $1,541.52 $1,615.80 $1,811.64 $1,899.44 $1,982.20 $2,390.76 $2,512.32
ARE MICRON READINGS NECESSARY?
What is it? A MICRON is 1/25400th of an inch of HG. Manifold charging and testing gauges typically only measure vacuum in FULL INCHES of HG and are totally incapable of measuring in thousands of the last inch on the gauge. No one can determine the last 1/2 inch of vacuum viewing a typical manifold gauge, much less the last thousands of an inch.
Service personnel need a “micron gauge” to determine when the system has reached a sufficient level of vacuum to cause the moisture to vaporize. (Moisture boils at lower temperatures as the atmospheric pressure is reduced.) Connecting a vacuum pump to a system and leaving it run for an hour or more, without checking the micron levels, doesn’t mean moisture has been removed. Numerous reasons why the system didn’t reach a sufficiently low micron level can and do occur. Only the micron readings confirm true vacuum and moisture removal. As the moisture is vaporized, the vacuum pump removes the vapor from the system. The lower the microns, the faster the moisture boils and the faster the vacuum pump can remove the vapor. The following is an example of the boil- ing point of water at a given atmospheric pressure:
Water boils at 212º F at 0” HG. 79 F at 29” HG. 32 F at 29.99” HG -15 F at 500 microns -25 F at 250 microns