ENERGY SAVER
AUTOMATIC ELECTRIC WATER HEATER TIMER
This low-cost 24 hour timer allows electric hot water heaters to be programmed to operate at preset inter- vals according to the home-owner’s hot water usage
schedule. Eliminates energy waste of maintaining maximum hot water temperature 24 hours a day. Water heater can be programmed to operate during periods of peak demand, such as several hours in morning and evening. Equipped with manual override control to allow immediate operation for special requirements without disturbing existing programs. Since a water heater uses more elec- tricity than any other appliance, the Paragon 4002 Timer can save as much as 33% of electricity costs. Construction features include timer dial driver by heavy duty synchronous motor and industrial type switch mechanisms to assure lasting, trouble-free operation. Enclosure is heavy gauge steel with wrinkle finish, and is equipped with a hasp for installation of padlock. Electrical specifications: 208/240 volts, 40 amp switch rating. UL listed.
CAT. NO. MFG. NO. DESCRIPTION 7C581
4002-71 EACH Paragon Electric Water Heater Timer 7000 Series 7-DAY TIME CLOCK
The ultimate for all heating, ventilating and air con- ditioning applications. 40 amp per pole non-induc- tive load. The 7000 Series allows automatic ON-OFF
operation at different hours each day if desired. Any date or days can be entirely omitted. Settings can be made a week in advance and changed if necessary. 4 pole construction---2 normally closed. Up to 28 ON-OFF operations per week or 4 ON-OFF operations per day. Completely adjustable, 3-hours minimum between opera- tions. Case dimensions: 10-7/8” high, 7-3/8” wide, 3-3/8” deep. 1 set of trippers mounted on dial; 6 extra sets included with each switch.
CAT. NO. MFG. NO. VOLTAGE SWITCH 7C564 7C568
7008-00 7008-71
X-4299 120 208-277
CAT. NO. MFG. NO. DESCRIPTION 7C625
EACH
2NO-2NC $281.31 2NO-2NC $292.86
Extra Trippers (set of 2)
EACH $7.66
4000 Series 24-HOUR TIME SWITCH
A general purpose, low-cost, 24 hour time control ideal for lighted signs, window displays, heating units, etc. Spring clutch dial drive permits manual check of ON and OFF operation. King-size termi- nal screws for easy wiring. Has 40 amp switch capacity at 120 or 208/240V AC. Up to 7 ON---7 OFF operation per day, 90 min- utes minimum between operations. Two trippers are furnished as standard.
CAT. NO. MFG. NO. VOLTAGE SWITCH EACH 7C576 7C580 7C583
4001-00 4003-00 4004-71
X-2772
120 120
208-277
SPST DPST DPST
CAT. NO. MFG. NO. DESCRIPTION 7C626
826 Extra Tripper (set of 2)
$124.51 $156.12 $155.51
EACH $6.29
$140.06
8040 Series COMMERCIAL
DEFROSTING CONTROL
The 8040 Series is an accurate and durable syn- chronous motored time switch of easy-to-set dual construction. It is designed primarily for the electric heat and reverse cycle or hot gas methods of defrosting commer- cial frozen food cabinets, dairy, delicatessen and vegetable display cases and walk-in coolers. Length of defrost adjustable from 4-110 min. in 2 minute increments. Defrost as often as every 4 hours. Contacts rated at 40 amps.
CAT. NO. MFG. NO. VOLTAGE EACH 7C608 7C612
8045-00 8045-20
X-3596
120 240
CAT. NO. MFG. NO. DESCRIPTION 7C624
Extra Tripper (1 Only)
$218.06 $218.06
EACH $5.97
8140 Series TIME INITIATED
REMOTE TEMPERATURE DEFROST CONTROL
For electric heat defrosting... hot gas or reverse-cycle defrosting. The length of de-frost is self-adjusting for varying loads and atmo- spheric conditions; accomplished by wiring an additional pressure switch or thermostat to the time control. The 8140 series has a defrost period termination fail-safe built into the time control dial. The fail-safe dial is adjustable from 4-110 minutes in 2 minutes in- crements. Defrost as often as every 4 hours. The time dial initiates the defrost cycle and a rise in pressure or temperature terminates the defrost cycle at pre-determined setting. Rated at 30 amps.
7C630 7C634 7C646 7C650
CAT. NO. MFG. NO. VOLTAGE NORMAL CONTACT POSITION A closed closed closed closed
8140-00 120 8141-20 240 8145-00 120 8145-20 240
X-3596
NORMAL CONTACT POSITION B open open open open
CAT. NO. MFG. NO. DESCRIPTION 7C624
Extra Tripper (1 Only)
NORMAL CONTACT POSITION C closed closed none none
EACH $5.97
8240 Series TIME INITIATED PRESSURE TERMINATED DEFROST CONTROL
The 8240 Series Defrost Control is time-initiated with termination being regulated over a wide range of pressure settings. Cut-in pressures range from 36 to 110 psi, thus allowing for R12, R22 and R502. There is a calibrated cut-in indicator with a pressure setting screw. As with the other defrost controls, the contacts are 2 HP, 40 amp pilot duty with AC voltages of 208-240. In addition to the pressure cut-in, the 8240 Series has backup mechanical defrost termination to protect against sensor failure. The timer allows settings from 4 to 110 minutes with two minute increments. One to six defrost cycles may be set per day with a minimum of four hours between cycle initiation. Contact design allows for hot gas, electric heat or compressor shutdown.
CAT. NO. MFG. NO. VOLTAGE EACH 2Q718
8245-20 208-240 $600.23 EACH
$236.91 $221.77 $201.81 $201.81