Compressor Overloads & Start Assists
START ASSISTS RELAY/OVERLOAD COMBINATION
Replaces all hermetic compressor relays and overloads with a single unit; can be used with start capacitor. Clip bracket mounting.
CAT. NO. MFG. NO. HP 1R241 1R240
RO-81 RO-41
1/4 & 1/3 1/12 thru 1/5
VOLTAGE EACH 115 115
3-IN-1 COMBINATION
Replaces relay, overload and start capacitor in capil- lary tube systems with a single unit. Prewired for easy installation.
CAT. NO. MFG. NO. HP 1R249 1R248
RCO-810 1/12 thru 1/5 115 RCO-410 1/4 & 1/3
115
VOLTAGE EACH $20.18 $18.49
RELAY/CAPACITOR COMBINATION
Provides increased starting torque for PSC air con- ditioning compressors; +300% with SPP-5, +500% with SPP-6, +690% with SPP-8.
CAT. NO. MFG. NO. HP 1R186 1R187 1R190
SPP-5 SPP-6 SPP8E
VOLTAGE
1/2 thru 10 1/2 thru 10 1/2 thru 10
120 thru 288 120 thru 288 120 thru 288
EACH $18.69 $28.16 $61.54
RELAY/CAPACITOR COMBINATION
One size for all domestic and commercial refrigera- tors and freezers up to 1/2 HP. Simple push-on wir- ing installation; clip bracket or screw mounting.
CAT. NO. MFG. NO. HP 1R207 1R208
RSC-10 RSC-20
1/12 thru 1/2 115 1/12 thru 1/2 230
VOLTAGE EACH $28.92 $29.65
$16.18 $16.18
ELECTRICAL CHECKS ON HERMETIC COMPRESSORS
ID the terminals... 1. Terminals are (C) Common, (S) Start, and (R) Run. They are always read “Left to Right, Top to Bottom”
o o o C S R
o o C S o
R o C
o o S R
o C o S o R
o C o R
o S
2. When in doubt, turn the power off, disconnect the wires from the compressor and measure the ohmic resistance between the terminals. The highest resistance will be from S to R. The next highest resistance will be from C to S and the lowest resistance will be from C to R. From these measurements, you can determine the actual individual terminal designations. The above isn’t as complicated as it sounds. Simply draw three “terminals” on a piece of paper in the configuration of the terminals on the compressor you are checking. Label them A,B,C, or what ever you want to label them. Begin measuring the resistances and noting them on the paper. Example: term (A) to term (B) = 4.5 ohms term (A) to term (C) = 2.0 ohms term (B) to term (C) = 6.5 ohms
conclusion: A to B is = to C to S ( Middle reading ) A to C is = to C to R ( Lowest reading ) B to C is = to S to R ( Highest reading)
Therefor...(A) term is actually Common (C) (B) term is actually Start (S) (C) term is actually Run (R)
PTC/CAPACITOR HARD START DEVICE
The SPP7S increases starting torque up to 600%. Installs in seconds across run capacitor terminals. Contains specially designed relay and large start capacitor for severe hard start problems.
CAT. NO. MFG. NO. HP VOLTAGE HG34617 SPP7S 1/2 thru 10 112 thru 230