COMPACT MOBILE HOME A-COILS
This uncased mobile home air conditioning and heat pump coil series is designed as a high efficiency A coil to be installed on new and existing downflow manufactured housing furnaces. Fits Nordyne, Intertherm, Miller, Evcon, Coleman and Airpro brands of furnaces. The series can be A.R.I. rated with many outdoor unit brands to provide a capacity range from 18,000 to 48,000 nominal BTU/HR. These coils are UL approved.
CAT. NO. MFG. NO.
7W503A 96-8G2T-0P R-22 7W504A 96-8G3T-0P R-22 7W504AB 96-8G4T-0P R-22 7W5045A 96-8W4X-0P R-22 7W5046 96-8W4M-0P R-22 7W505A 97-8W5X-0P R-22 7W506A 98-8W7X-0P R-22 7W5045B 96-8W4D-0P R-410A 7W5045C 96-8W4Y-0P R-410A 7W506B 96-8W7Y-0P R-410A
3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8”
3/4” 3/4” 3/4” 7/8” 7/8” 7/8” 7/8” 3/4” 7/8” 7/8”
ON ALL COILS
REFRIGERANT DIMENSIONS H x W x D CONNECTIONS LIQUID CONNECTIONS SUCTION WEIGHT EACH 14-1/2 x 18 x 19-5/8” 16-1/2 x 18 x 19-5/8” 18-1/2 x 18 x 19-5/8” 18-1/2 x 18 x 19-5/8” 18-1/2 x 18 x 19-5/8” 20-1/2 x 18 x 19-5/8” 24-1/2 x 18 x 19-5/8” 18-1/2 x 18 x 19-5/8” 18-1/2 x 18 x 19-5/8” 24-1/2 x 18 x 19-5/8”
25 lbs 30 lbs 31 lbs 39 lbs 39 lbs 42 lbs 48 lbs 32 lbs 39 lbs 43 lbs
Note: Use of third party (Mortex) coils with outdoor units will not allow registration upgrades from the standard manufacturers warranty on the outdoor unit.
$582.12 $625.60 $696.90 $831.61
$910.95
$1,007.57 $803.13 $803.13 $957.03
ACCESSORIES FOR MORTEX MOBILE HOME COILS CAT. NO. MFG. NO. DESCRIPTION
EACH
7W516 R72DB003 TXV - R-410A for 1-1/2 thru 3 tons $124.77 7W516A R72DB004 TXV - R-410A for 2-1/2 thru 5 tons $124.77 7W515K 99-0111-87 Drip Shields for 96-8-3 & 8-4 Coils
AirEase AC unit to Mortex coil Match-ups CAT. NO. MFG. NO. CAT. NO. MFG. NO.
30H1426 4SCU14LE124P 7W504AB 96-8G4+TXV+TDR yes 30H1427 4SCU14LE130P 7W504AB 96-8G4+TXV+TDR yes 30H1428 4SCU14LE136P 7W5045B 96-8W4+TXV+TDR yes 30H1429 4SCU14LE142P 7W5045C 96-8W4+TXV+TDR yes 30H1430 4SCU14LE148P 7W506B 30H1431 4SCU14LE160P 7W506B
98-8W7+TXV+TDR yes 98-8W7+TXV+TDR yes
Note: TDR required on above to obtain listed ratings.
TXV REQ. COOLING CAPACITY EER 23400 28000 34000 40500 45000 52000
12.00 12.00 12.00 12.00 11.85 11.85
SEER AHRI # 14.00 14.00 14.00 14.00 14.00 14.00
3634032 3634033 3634034 3634035 3634036 3634037
AirEase HP unit to Mortex coil Match-ups CAT. NO. MFG. NO. CAT. NO. MFG. NO. Note: TDR required on above to obtain listed ratings. Armstrong AC unit to Mortex coil Match-ups
CAT. NO. MFG. NO. 10H1094 10H1095 10H1096
CAT. NO. MFG. NO.
4SCU13LE142P 7W5045B 96-8W4+TDR no 4SCU13LE148P 7W5045C 96-8W4+TDR no 4SCU13LE160P 7W5045C 96-8W4+TDR no
Note: TDR required on above to obtain listed ratings.
TXV REQ. COOLING CAPACITY EER SEER AHRI # 41000 47000 51000
11.00 11.00 10.00
13.00 3509183 13.00 3509186 13.00 3509187
30H1446 4SHP14LE124P 7W5045B 96-8W4+TXV+TDR yes 30H1447 4SHP14LE130P 7W506B 98-8W7+TXV+TDR yes
TXV REQ. COOLING CAPACITY EER SEER HEATING CAPACITY HSPF AHRI # 23000 28000
11.80 11.50
14.00 14.00
22800 27600
7.70 7.70
3628219 3628204
Visit us at www.remichel.com
171
AIR CONDITIONING & HEATING EQUIPMENT