Duct Board
FIBER GLASS DUCT BOARD QuietR™
Owens Corning EnDuraGold™ Fiber Glass Duct Board is a rigid, resin bonded fibrous glass board with a tough, damage-resistant, flame retardant, reinforced aluminum foil (FRK) facing. When fab- ricated into duct systems, it combines excellent thermal and acoustical insulating properties with substantially airtight transmission of air when all joints are sealed with UL 181A listed closures.
Features a durable, biocide treated air stream surface that isolates the glass fiber substrate from the airstream and inhibits penetration of the insulation by dirt, dust and other pollutants. Duct systems built with these boards absorb fan and air turbulence noise, reduce popping noises caused by ex- pansion, contraction and vibration. Fabrication and installation are quieter. The tough flame-retar- dant vapor barrier eliminates sweating from condensation, assures fire-safety and resists damage. Ideal for heating and cooling applications to a maximum of 250ÞF in temperature and 6000 FPM in velocity and 2” static pressure. Type 800FRK is stiffer and more suited to commercial applications.
CAT. NO. TYPE 8H965 8H966
8H973B 8H973
8H9731 DESCRIPTION
475FRK 1” x 48” x 96” Duct board 475FRK 1” x 48” x 120” Duct board
R-FACTOR CARTON QUANTITY EACH R 4.3 R 4.3
800FRK 1-1/2” x 48” x 96” Duct board R 6.5 800FRK 1-1/2” x 48” x 120” Duct board R 6.5 1400FRK 2” x 48” x 120” Duct board
R 8.7
6 6 6 6 3
$51.82 $89.52 $68.84
$120.84 $124.03
ALL SERVICE DUCT WRAP INSULATION for Air Handling Systems
SOFTR™ All-Service Fiber Glass Duct Wrap helps control moisture condensation on the ductwork as well as on the outer vapor retarder jacket. This helps maintain insulation efficiency and reduces the likelihood of stained ceilings due to moisture damage. SOFTR™ All-Service Fiber Glass Duct Wrap is a blanket of glass fiber insulation factory-laminated to FRK vapor retarder facing. A 2” stapling and taping flange are provided on one edge.
This product is designed to meet existing performance standards such as NFPA90A and 90B and other model building and energy codes. It is used for external insulation of commercial and resi- dential heating, A/C and dual-temperature ducts operating at temperatures from 40°F to 250°F. Do not expose to weather or use inside of duct.
REINFORCED FOIL/ALL-SERVICE JACKET VAPOR BARRIER CAT. NO. MFG. NO. INSTALLED R-FACTOR SIZE
EACH
8H951 8H950
8H950R 8H949A
373626 373627 373899 373991
R 4.2 R 5.6 R 6.0 R 8.3
1 -1/2” x 48” x 100 ft. $251.04 2” x 48” x 75 ft. 2.2” x 48” x 75 ft. 3” x 48” x 50 ft.
$214.92 $196.71 $217.36
906