S87 Series ELECTRONIC DIRECT SPARK IGNITION MODULE
Replacement modules for Honeywell and most other brand direct spark ignition systems used on furnaces, boilers and heating appliances.
May be used with any DSI gas valve rated at 2.0 amps or less. Uses separate electrodes for spark ignition and flame sensing. Automatic system lockout after trial for ignition. Electrical rating: 25v AC @ 2.0 amps.
CAT. NO. MFG. NO. MAX. LOCKOUT TIME APPLICATION 2C526
S87D1004 6 sec. EACH 100% safety shutoff,Natural or LP gas $313.23
UNIVERSAL ELECTRONIC HOT SURFACE IGNITION (HSI) MODULE S8910 Series
Universal replacement module for all single or dual rod hot surface ignition systems using Norton 201 and 271 or equivalent ignitors. Allows one-time selection of one or three ignition trials per call for heat, and four second or seven second trial periods. Includes LED status display.
Replaces Honeywell S89, S890; White-Rodgers 50E47, 50F47; Robertshaw HS780. Electrical ratings: 24v AC control voltage; 120v AC HSI ignitor voltage.
CAT. NO. MFG. NO. 2C531
TIME S8910U1000 96 sec.*
APPLICATION Natural or LP gas
EACH $244.34
S89F Series ELECTRONIC DIRECT SPARK IGNITION MODULE
Provides electronic control of direct spark ignition systems, with external spark transformers, used on gas-fired fur- naces, boilers, conversion burners and other heating appliances.
May be used with any DSI gas valve rated at 2.0 amps or less. Uses separate electrodes for spark ignition and flame sensing. Electrical rating:Two power supplies required. 24v and 120v, 2.2 amps @ 24v, 1.5 amps @ 120 v.
CAT. NO. MFG. NO. MAX. LOCKOUT TIME APPLICATION 2C536
S89F1106 4 sec. EACH Natural or LP Gas $338.83
S8610U Series ENHANCED UNIVERSAL INTERMITTENT IGNITION MODULE
The S8610U series incorporates all of the features of its predecessors PLUS. This control works on intermittent pilot ignition systems using combination ignitor/sensors in furnaces, boilers and other heating appliances. Improvements include “field selectable diagnostics”. Module is suitable for use with vent dampers and use with natural or LP gas. Provides ignition sequence, flame monitoring, and safety shutoff functions. EnviraCOM Enabled.
New improved model replaces: S86, S860, S90 S8610U1008, S8610F1008, S8610H1004, S8610H1020, S8610H, 1025, S8610U1003, S8610U1004, S8610U1008, S8610U1025, S8670D1000, S8670U1000, S8680J1004 and S8680U1004.
CAT. NO. MFG. NO. 2C560U
FIELD SELECTABLE OPERATION SEQUENCE ELECTRICAL RATINGS
S8610U3009 0 or 30 second prepurge 15 or 90 second trial for ignition
Pilot - 1.0 amp running, 10.0 amps inrush Main - 2.0 amps running, 20.0 amps in rush
EACH $245.43
748
CONTROLS