HIGH EFFICIENCY GAS BOILERS
Munchkin boilers modulate its firing rate to match energy needs of the living space. This feature pro- vides additional savings versus traditional single firing boilers. With stainless steel construction, you can be assured that you are buying the highest quality appliance. It’s compact, light-weight design allows installation virtually anywhere. Zero clearance to combustibles and a small footprint. Direct vent with standard schedule 40 PVC plastic pipe*. Proven European technology, manufactured in the United States. A quiet operational appliance is just another benefit that comes with the Munchkin boiler. The patented Munchkin heat exchanger has been designed to provide maximum heat transfer, while also providing unsurpassed corrosion resistance with stainless steel construction. Stainless steel burner with reliable spark ignition coupled with gas valve and Venturi system. This pre-mix combustion system is the engine which provides reliable and efficient operation. The new Munch- kin 926 controller is engineered to modulate the firing rate to match the actual needs of the heat- ing system, saving money not wasting energy. The digital readout indicates supply temperature in normal operation and displays a digital code to indicate a failure in the system, making troubleshoot- ing easier. Additional features consist of sealed combustion, wiring harness, water pressure switch, supply/return temperature thermister, 24 volt transformer, burner fan, heater jacket, spark electrode, rectification probe, electrical junction box with switch, high limit temperature control, 30 psi relief valve, combination pressure/temperature gauge. Pre-wired for use with vision 1 controls.
CAT. NO. MFG. NO. DOE HEATING CAPACITY BTU/HR
9W400N 80M 9W402N 140M 9W404NA 199M 9W406N 399M
25,000 to 74,000 INPUT 80-27 BTU
43,000 to 129,000 140-46 BTU 61,000 to 183,000 199-66 BTU 93,000 to 279,000 399-100 BTU
140M 199M 399M
26 x 21 x 22-1/4” 26 x 21 x 30-3/4” 26 x 21 x 30-3/4”
26 x 18-1/4 x 44-1/2”
*Solid PVC or ABS NOT Foam Core Pipe. ** Above boilers are ASME approved.
WALL MOUNT MODEL
This fully enclosed boiler is whisper quiet and certified for sealed combustion or direct vent applications. It uses standard 2” schedule 40 PVC pipe for both intake and exhaust air. Total equivalent lengths of vent pipe are up to 80’ depending on where the transition point is located. System connections are 1-1/4” left side mounted for both supply and return water and 3/4” gas connection. 120V 60 Hz.
Boiler is shipped with vent termination and tee, 30 PSI relief valve and pressure temperature gauge. Another feature of this boiler is an 8 PSI water pressure switch mounted in the outlet manifold. This will assure that in the event of a leak, the Munchkin will lock out to prevent damage to the stainless steel heat exchanger.
CAT. NO. MFG. NO. DOE HEATING CAPACITY BTU/HR
9W398 T-80M 9W397 T-50M
17,000 to 74,000 18,000 to 50,000
26-1/2 x 17-1/2 x 12-3/4” 26-1/2 x 17-1/2 x 12-3/4”
INPUT MODULATION MBH
80 - 19 BTU 50 - 19 BTU
1-1/4” NPT 1-1/4” NPT
I=B=R NET RATING BTU/HR
64,000 40,000
A.F.U.E.% COMBINED
95.1 95.1
1-1/4” NPT 1-1/4” NPT
INLET&OUTLET VENT LENGTH(EQUI.FEET)MIN 16 16
COMBINED
INLET&OUTLET VENT LENGTH(EQUI.FEET)MAX 85 85
3/4” NPT 3/4” NPT
FLUE EACH
2” 2”
58 58
$5,029.58 $4,548.59
MFG. NO. DIMENSIONS H x W x D PIPING CONNECTIONS SUPPLY PIPING CONNECTIONS RETURN PIPING CONNECTIONS GAS WEIGHT T-80M T-50M
CAT. NO. 9W496 9W410 9W411 9W538
MFG. NO. DESCRIPTION
ACCESSORIES FOR MUNCHKIN GAS BOILERS CAT. NO.
EACH
KGAVT0601CVT 3” Concentric Vent V1000 V2000 N1100
$176.43
3” Stainless Steel Outside Termination Kit $329.65 4” Stainless Steel Outside Termination Kit $482.47 Condensate Filter (neutralizer)
$116.36
2R325 9W411
MFG. NO. 554200 V2000
9W395LPK 7250P-714
1-1/4” NPT 1-1/4” NPT 1-1/4” NPT 2” NPT
FLOOR MOUNT MODELS A.F.U.E.% COMBINED
MODULATION MBH
I=B=R NET RATING BTU/HR
64,000 112,000 159,000 319,000
95.1 95.1 95.1 95.1
1-1/4” NPT 1-1/4” NPT 1-1/4” NPT 2” NPT
INLET&OUTLET VENT LENGTH(EQUI.FEET)MIN 16 16 16 16
COMBINED
INLET&OUTLET VENT LENGTH(EQUI.FEET)MAX 85 85 85 85
3/4” NPT 3/4” NPT 3/4” NPT
AGAINST LEAKS
ON BLOWERS
ON ALL PARTS
FLUE EACH
3” 3” 3” 4”
75
$4,790.85 $6,707.86 $7,516.04 $14,489.27
MFG. NO. DIMENSIONS H x W x D PIPING CONNECTIONS SUPPLY PIPING CONNECTIONS RETURN PIPING CONNECTIONS GAS WEIGHT 80M
1-1/4” NPT
101 111 252
DESCRIPTION Condensate Pump Outside Termination kit for 399M
Natural to LP conversion kit for all models with Dungs gas valve
EACH
$162.90 $482.47 $23.41