EVAPORATOR/AIR HANDLERS - LEFT SIDE RETURN For use with GSC/GTC compressor bearing units
VERTICAL DISCHARGE MODELS Evaporator/air handlers for use with GSC/GTC compressor bearing units. CAT. NO. MFG. NO.
10G158 GSE024A1LT1A ECM 32 x 22 x 25-1/2” 10G154 GSE024A1LT0A PSC 10G159 GSE036A1LT0B PSC
32 x 22 x 25-1/2” 34 x 26 x 30-1/2”
38 x 26 x 30-1/2” 38 x 28 x 30-1/2”
10G155 GSE036A1LT1B ECM 34 x 26 x 30-1/2” 10G160 GSE048A1LT0C PSC
10G156 GSE048A1LT1C ECM 38 x 26 x 30-1/2” 10G161 GSE060A1LT0D PSC
10G157 GSE060A1LT1D ECM 38 x 28 x 30-1/2
MOTOR DIMENSIONS H x W x D CONNECTIONS LIQUID CONNECTIONS SUCTION COND. CONN. EACH 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 1/2” 1/2”
5/8” 5/8” 3/4” 3/4” 3/4” 3/4” 7/8” 7/8”
3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4”
$2,784.00 $3,052.00 $3,046.00 $3,312.00 $3,282.00 $3,550.00 $3,604.00 $3,870.00
LINE SIZING REQUIREMENTS For GSC/GTC units with GSE air handlers
MFG. NO.
GSC/GTC024 w/ GSE 3/8” GSC/GTC036 w/ GSE 3/8” GSC/GTC048 w/ GSE 1/2” GSC/GTC060 w/ GSE 1/2”
20 ft. Length LIQUID 20 ft. Length SUCTION 50 ft. Length LIQUID 50 ft. Length SUCTION 5/8” 3/4” 7/8” 7/8”
3/8” 1/2” 1/2” 1/2”
3/4” 7/8”
1-1/8” 1-1/8”
UNIT PERFORMANCE - FORCED AIR COMPRESSORS GROUND LOOP HEAT PUMP APPLICATION GROUND WATER HEAT PUMP APPLICATION
Forced Air Models (ECM Fan Motor) 1-Stage Single Compressor
MODEL
GS018C/E 5.0 GS024C/E 6.0 GS030C/E 7.0 GS036C/E 9.0 GS042C/E 11.0 GS048C/E 13.0 GS060C/E 15.0 GS072C/E 18.0
GPM HEATING BTU/HR 13,300 20,000 25,800 30,000 35,000 42,200 47,600 57,900
HEATING COP 3.5 3.5 3.5 3.4 3.4 3.3 3.3 3.2
COOLING BTU/HR 16,700 25,000 32,300 37,600 43,800 53,200 59,500 72,000
Note: Heating at 32°F EWT. Cooling at 77°F EWT.
COOLING EER 18.0 17.1 17.6 17.1 17.1 16.9 15.4 15.2
Forced Air Models (ECM Fan Motor) 1-Stage Single Compressor
MODEL
GS018C/E 5.0 GS024C/E 6.0 GS030C/E 7.0 GS036C/E 9.0 GS042C/E 11.0 GS048C/E 13.0 GS060C/E 15.0 GS072C/E 18.0
GPM HEATING BTU/HR 15,300 22,900 29,600 34,400 40,200 48,500 54,800 66,500
HEATING COP 4.0 4.0 4.0 3.9 3.9 3.8 3.8 3.7
COOLING BTU/HR 17,400 26,300 34,000 39,400 46,000 55,900 62,500 75,500
Note: Heating at 50°F EWT. Cooling at 59°F EWT. GROUND WATER HEAT PUMP APPLICATION
GTC024 7.0 GSE024 4.0 GTC036 9.0 GSE036 5.0
MODEL GPM HEATING BTU/HR - -
34,200 -
GTC048 12.0 49,700 GSE048 7.0
-
GTC060 15.0 57,000 GSE060 10.0 -
Forced Air Models (ECM Fan Motor) Dual Capacity/Single Compressor Part Load
HEATING COP - -
3.9 -
3.8 -
3.8 -
COOLING BTU/HR - -
39,200 -
57,000 -
65,100 -
COOLING EER - -
19.7 -
19.2 -
19.0 -
Part Load HEATING BTU/HR - - -
22,800 -
33,000 -
39,800
Part Load HEATING COP - - -
4.9 -
4.7 -
4.7
- - -
Part Load
COOLING BTU/HR COOLING EER - - -
36,200 -
37,700 -
45,500
26.2 -
26.0 -
25.8
Note: Heating at 50°F EWT. Cooling at 59°F EWT. Rated in accordance with ISO Standard 13256-1 which includes Pump Penalties. Heating capacities based on 68°F DB, 59°F WB entering air temperature. Cooling capacities based on 80.6°F DB, 66.2°F WB entering air temperature.
COOLING EER 20.6 19.7 20.2 19.7 19.7 19.4 17.7 17.5
276