Systems Continued from page 64


Coating Complex Electronics with Flexible Dispensing


components that are not sealed. The use of a liquid coating may be diffi- cult, as the material may migrate to areas of the assembly based on board


masking material or a material line. l


After the masking material is dis- pensed, the system sets the valve back into place and picks up the UV wand, which is used to cure the material.


l


When the cure process is completed, the PrecisionCoat will select a second dispense valve, which is tied to different material line, and will outline various components, including dispensing between closely placed components.


l After the dispense valve is


put back in its place, the spray tool will be selected to com- plete the application of confor- mal coating to the PCB.


It is important to note that


PrecisionCoat V conformal coating and dispensing system.


design, solder mask finish and/or ambient conditions. To combat this, the Precision -


Coat AQC feature enables customers to isolate the components with a masking material (e.g., a gel coat, RTV, etc.) prior to spray coating the balance of the board. AQC can accomplish this easily in a few steps:


l The PrecisionCoat begins by pick-


ing up a dispense valve, which can be connected to either a cartridge of


with the SCS Precision Coat and AQC, all of the above steps, including many possible varia- tions, can be programmed in a single coating profile, which can be executed without any user intervention. One of the biggest benefits of an SCS Precision Coat


is that the platform is designed for not only immediate needs, but is versatile to meet future demands as well. The flexibility of five heads/ valves and the AQC feature is enabling the PrecisionCoat system to be long-term solution for future applications. Contact: Speciality Coating


Systems, Inc., 7645 Woodland Drive, Indianapolis, IN % 317-451-8549 fax: 317-240-2739 Web: www.scscoatings.com r


See at IPC APEX, Booth 2307 CableEye


Whether you're an R&D engineer designing cables for a new product or a production worker checking hundreds of cables an hour, CableEye's unique graphic wiring display tells you what you need to know clearly and immediately.


Graphically see missing or shorted conductors, miswired cables, reversed diodes, and backward connectors. Print crystal-clear test results including the wiring schematic. Graphically compare two cables by alternating the display between your test result and the ideal cable. Run a high-speed resistance test loop while you flex the cable to check for


®


Professional Test System for Cables and Wire Harnesses


Fault


CableEye Wiring Report Name: HD44M-HD44F-S39X


Socket L HD44 Male


SH 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 21 22 23 24 25 26 27 28 29 30 16 17 31 32 33 34 35 36 37 38 39 40 41 42 43 44 M A T C H D A T A 1-6-18 10:57 AM


Print your company information here. Set up in Preferences / Print Options. Z-AXIS CONTROLLER CABLE


Socket R HD44 Female


SH 31 32 33 34 35 36 37 38 39 40 41 42 43 44 21 22 23 24 25 26 27 28 29 30 5 6 7 8 9 10 11 12 13 14 15 16 2 3 Continued from page 68


the selective machine to perform the rework. The board will then continue down the production line. The most efficient and


most popular system is one in which the selective soldering is in parallel with the AOI machine and linked by shuttle conveyors. The rejected board is shuttled off of the line to the selective system to be reworked. The board is then passed back to the line prior to the AOI. This allows the reworked board to be inspected again, ensuring that only quali- ty boards pass down the pro- duction line, with the use of only a single inspection system. With this procedure, there is every chance that the cycle time can be maintained and yield rates significantly increased. An alternative approach is to


March, 2018 Solving Wave Solder Issues...


or Pilot soldering systems. This allows failed boards to be reworked in batches and then reintroduced


Landrex Optima III solder inspection system.


use the AOI system to inspect the production in-line and shuttle off any


into the production line later. The use of barcodes allows the operator to ensure that the correct rework process program is executed, while maintaining full traceability and the ability to generate yield reports. Integrating AOI and rework


Pillarhouse selective soldering micro nozzle.


failed boards to a board unloader for storage. These boards can then be reworked with a low-cost off-line sys- tem, such as Pillarhouse’s Jade Mk II


into production directly after wave soldering allows a host of defects to be corrected long before the board reaches the end of the line. By using AOI and selective solder machines that communicate with each other, scrap can be reduced and manual rework time can be saved. Contact: Pillarhouse USA, Inc.,


201 Lively Boulevard, Elk Grove Village, IL 60007 % 847-593-9080 fax: 847-593-9084 E-mail: sales@pillarhouseusa.com Web: www.pillarhouse.biz r


See at IPC APEX, Booth 1309


N E T L I S T


L-SH L-1 L-2


-L-3 L-4 L-6 L-7 L-8 L-9


L-10 L-11 L-12 L-13


Actual Screen Display Win XP3 or later


Touch-screen compatible


CableEye Model M3U, Expandable to over 2500 Test Points. Use with Laptops Too!


intermittent connections. Trace hidden wires graphically with our minihook probes. Log test results and print batch reports.


See what our customers say about return-on-investment at


camiresearch.com/testimonials


R-SH L-17 R-2


+R-3


L-5 R-5 R-6 R-7 R-8 R-9


R-10 R-11 R-12 R-13


 


N O T E S


Z-AXIS CONTROLLER CABLE Connector Type: High-density Dsub, 44 pins. Connector must have machined pins and metal shell. Use AMP part 778224-6.


NOTE: Pins 10-15 and 40-44 of this high-density cable carry rarely-used signals and may not be wired in the cable you are testing. This is acceptable.


L A B E L


Z-AXIS CONTROLLER Part Number 355-425A


CableEye® by CAMI Research Inc.  


Fully Document Cables for your Own Records or for your Customers'


How much is your time worth? Chances are that it won't take long for CableEye to earn back your investment (basic systems start at $1295).


Try a Free Demo Unit Today!


Still servicing testers over 20 years old! 1 Yr Renewable Warranty


Free Tech Support!


CAMI Research Inc. ®


CableEye +1 978-266-2655 | sales@camiresearch.com ®


s 0.5


e c


.


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108  |  Page 109  |  Page 110  |  Page 111  |  Page 112  |  Page 113  |  Page 114  |  Page 115  |  Page 116  |  Page 117  |  Page 118  |  Page 119  |  Page 120  |  Page 121  |  Page 122  |  Page 123  |  Page 124  |  Page 125  |  Page 126  |  Page 127  |  Page 128  |  Page 129  |  Page 130  |  Page 131  |  Page 132  |  Page 133  |  Page 134  |  Page 135  |  Page 136