This page contains a Flash digital edition of a book.
February, 2017


www.us- tech.com


Page 101 Gen3 Presents Ionic Contamination Test System


Farnborough, UK — Gen3 Systems Limited, along with Ascentech, are displaying the new CM+ series of ionic contamination test systems and the AutoSIR 2 and AutoCAF 2 insu- lation resistance testers. The CM+ series is a combined


ROSE and PICT ionic contamination test system and offers complete test- ing in three minutes. The system recirculates its entire tank volume six times per minute. Its solid-gold measuring cell and ballistic amplifier provide a test accuracy of less than 0.005 mS/cm. The system comes equipped with a curve-fitting analy-


Purex Improves Fume Extraction Filters


Schaumburg, IL — Purex has upgraded the filter design for its fume extraction systems, which clear the air of gases and particulates for a range of applications including selec- tive soldering, reflow and laser marking. The company’s filters are used throughout the industry to fil- ter the air and remove the harmful material generated by laser coding and engraving, hand and machine soldering, chemical handling, coat- ing, spraying, and other processes. The filters use a combination of


KYZEN ANALYST™ The world’s first


real-time concentration monitoring and analytics system designed for all. Not just a few.


Fume extraction system.


blended charcoal to adsorb gases and high-grade H14 HEPA media to cap- ture particles as small as 0.3 µm with a stated efficiency of 99.997 percent. The company’s robust Zintec steel fil- ters have been upgraded and now include new galvanized steel filter cases. Like Zintec, galvanized steel helps prevent corrosion. Both kinds of Purex filter perform much better than wooden or cardboard framed fil- ters. Filters made from cardboard, wood or MDF are prone to leakage when they encounter moisture in the fume. Purex filters are specifically designed to avoid the health and safety issues that come with expos-


ing people to hazardous fumes. Contact: Purex, Inc., 2246


Palmer Drive, Suite 108, Schaumburg, IL 60173 % 866-360- 5675 E-mail: purex@purexinc.com Web: www.purexinc.com


See at IPC APEX, Booth 2625 See at APEX, Booth 2401 KYZENAnalyst.com Copyright t © KYZEN Corporation 2016. All Rights Re eserved.


Introducing KYZEN ANALYST, the reliable, accurate wash bath concentration monitoring system that maximizes performance of all chemistries, not just one. Plus easy access to real-time data from anywhere makes retrieving, logging and charting SPC reports fast and user friendly, saving you critical time and labor. Monitoring is now faster, safer and more precise, thanks to KYZEN, the global leader in manufacturing cleaning processes and control technology.


Go to KYZENAnalyst.com for more information. WORLDWIDE ENVIRONMENTALLY RESPONSIBLE CLEANING TECHNOLOGIES


sis algorithm and fully regenerates in under six minutes. Designed to provide bubble-free circulation at all times, the system offers accurate measurements even when the pro- portion of test solution to surface area under test is large. The system also provides auto-


matic temperature compensation, measures in accordance with all international and MIL specifications both old and new, and is available with a new range of PCB and compo- nent handling frames, as well as an integrated draining system. The series is available in six different models with six different tank sizes. When selecting a test system it is important to use the smallest possi- ble tank size for the unit under test. The company is also offering its


AutoSIR 2 and AutoCAF 2 insulation resistance testers, available in 64, 128 or 256 channel configurations. Key features include: 256 channel


measurement time of less than 8 sec- onds; applied voltage of +1 to +500V, with the CLR1000 extending the test voltage to 1,000V; a measurement range of 106 to 1014W; continuous measuring on all selected tests; fully- selectable measurement test inter- vals with a minimum of one minute; and are capable of testing to all exist- ing test specifications, including IPC,


IEC, and JNC. Contact: Gen3 Systems Ltd.,


Unit B2, Armstrong Mall, Southwood Business Park, Farnborough, Hampshire, GU14


CM series ionic contamination test system.


0NR, UK % +44-0-12-5252-1500 fax: +44-0-12- 5252-1500 E-mail: sales@gen3systems.com Web: www.gen3systems.com


See at IPC APEX, Booth 3136


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108  |  Page 109  |  Page 110  |  Page 111  |  Page 112  |  Page 113  |  Page 114  |  Page 115  |  Page 116  |  Page 117  |  Page 118  |  Page 119  |  Page 120  |  Page 121  |  Page 122  |  Page 123  |  Page 124