040 REPORT
VICARAGE ROAD
Company:
Lab.gruppen Location: Watford, UK
For fans of a football club, few sporting venues can match the excitement of your home ground, and Watford’s famous Vicarage Road is no exception. Of course, with thousands of fans attending week in, week out, it is important for venues like this to have an audio system that is suitable, not only for announce- ments relating to games and team matters, but also one that complies with all relevant standards and legislation relating to mass-notification and voice alarm in sports venues. However, in recent years the existing PA system at the 19,900-ca- pacity Vicarage Road football ground was becoming unreliable and there was doubt as to whether it could perform as expected in the event of a public emergen- cy situation. In compliance with the Green Guide and building regulations, an annu- al safety review of the audio system for life-safety was carried out by Watford FC and Sennheiser UK. It was this review that established the need for an extensive upgrade. It was necessary to supply a system that provides sufficient coverage for the ground, improving the audio performance in the bowl area for sports presenta- tion. However, the system also had to be flexible and powerful enough to supple- ment any non-sporting live events held in the ground, such as concerts by lifelong Watford fan Sir Elton John. Another stipulation was that the system needed to be installed during the football season and around the venue’s many conferences and events. Watford called in respected system designer Roland Hemming of RH Consulting, who worked with Sennheiser UK to specify a system that could cope with every eventuality. Hemming’s solution comprises a combination of DAS and APart loudspeakers, with over 200 loudspeakers split into 20 zones. The new bowl systems covers three of the four stands, with the East Stand left unchanged and integrated into the new system. On site installation took nine weeks, and was performed by E-Mech Entertainment Engineering - with Huw Micklewright - with the existing PA / VA system remaining in place and connected to the new ampli- fiers and loudspeakers during the process, allowing 100% uptime of the PA / VA system during the transition from old to new. When it came to deciding on how to control and power this extensive loudspeaker installation, Hemming opted for a fa- miliar configuration that utilised the individual capability and compatibility elements of Peavey MediaMatrix NION n6 and PLM Series,
Lab.gruppen’s flagship powered loudspeaker management platform. Designing the system around the MediaMatrix NION’s provided the benefit and security of being able to implement a networked dual redundant ring configuration - eliminating audio network down-time caused by a single point of failure. This was critical to the system’s fulfilment of dual roles as
www.mondodr.com
both standard PA and VA. Among other notable benefits, the deployment of Lab. gruppen PLM Series meant the new system could be designed around Dante - viewed increasingly as the new ‘de-facto’ low latency digital audio network protocol - given that the PLM Series is fully capable on this front. “We’re driving all of the circuits,” said Roland. “A number of 100V line circuits for all the concourse and corridors; and high power circuits into the bowl, with very high SPL levels to cover those areas. The reason we like using
Lab.gruppen PLM Series is that they can do both. “We’re using the custom software that allows us to view, monitor and control the PLMs from within the NIONs, so it makes integration very easy. We have a nice touchscreen display that shows us all of the 20 zones, and Dante allows us to use one system for monitoring and control. There are no latency issues, no issues with bundles that you might have with CobraNet, and all in all, it’s a very simple network.” There are two rack positions, one in the North and one in the South connected together in a dual redundant fibre optic loop. Around 12km of fire proof cable connects to the loudspeakers. “The PLMs have all of the processing built into them, so there’s a lot less program- ming involved in the set up,” Ronald continued. “We’re using the NIONs very simply to provide inputs, routing and control, but all of the loudspeaker tuning is done by the PLMs, so it’s an ideal solution for the stadium.” “The other reason for PLMs is that they distribute the processing, so if we do have any failures within the NIONs, the DAS loudspeakers will still sound optimal. We’re using both two and four channel amplifiers, and they are compact, so the entire thing fits into two racks. The initial cost may be slightly higher when compared with other amplifier platforms in the same power bracket, however, due to the PLM’s universal power supply and the relatively low current draw, your overall cost of ownership is significantly lower. In terms of total cost of installation and ownership, PLM Series is actually a very compelling amplifiers to use for voice alarm applica- tions.” The new system is compliant with the latest British standards BS5839 Part 8 and BS7827, a Code of Practice for designing, specifying, maintaining and operating emergency sound systems at sports venues. It is the first system to be signed off against the latest revision of BS7827, launched in September 2011. Hemming concluded: “The entire system has provided a significant improvement on what was there previously. It’s a nice stadium system that is both adaptable in terms of usability and also very cost effective. The combination of the MediaMatrix NIONs integrating with the
Lab.gruppen amplifiers via Dante works very well, and the clar- ity and definition of the DAS loudspeakers gives us an exemplary system. In many ways, such as pounds per decibel, this whole system is amazingly good value.”
www.labgruppen.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108 |
Page 109 |
Page 110 |
Page 111 |
Page 112 |
Page 113 |
Page 114 |
Page 115 |
Page 116 |
Page 117 |
Page 118 |
Page 119 |
Page 120 |
Page 121 |
Page 122 |
Page 123 |
Page 124 |
Page 125 |
Page 126 |
Page 127 |
Page 128 |
Page 129 |
Page 130 |
Page 131 |
Page 132 |
Page 133 |
Page 134 |
Page 135 |
Page 136 |
Page 137 |
Page 138 |
Page 139 |
Page 140 |
Page 141 |
Page 142 |
Page 143 |
Page 144 |
Page 145 |
Page 146 |
Page 147 |
Page 148 |
Page 149 |
Page 150 |
Page 151 |
Page 152 |
Page 153 |
Page 154 |
Page 155 |
Page 156