February, 2020
www.us-
tech.com
WAGO Unveils Next-Gen I/O System Controller with PROFINET
Germantown, WI — WAGO has expanded its family of PFC200 Generation 2 controllers with the
switched for use as a line configura- tion enabling the controller to func- tion as an I/O device connected to a PROFIBUS master. The two Ethernet ports can be used in a switched configuration or sepa- rated and support other proto- cols, such as EtherCat and Sparkplug (with additional licenses). Other features of the 750-
8215 controller include: USB-A port with removable memory to extend memory capabilities of the
controller; high-speed PFC200 750-8215 I/O system controller.
release of its new 750-8215. The 750- 8215 is IIoT-ready, comes with two Ethernet ports, two PROFINET ports, and is programmable with WAGO’s
e!COCKPIT software
(CODESYS 3.5). The PROFINET ports are
processor for complex applica- tions; large onboard memory plus SD card slot; built-in web server; and a CANopen port that allows connection to other
devices on a controller area network. Contact: WAGO Corporation, N120 W19129 Freistadt Road,
Germantown, WI 53022 % 262-255-6222 fax: 262-255-3232 E-mail:
info.us@
wago.com Web:
www.wago.us
CAS DataLoggers Intros
Compact Data Acquisition and Control System
Chesterland, OH — CAS has intro- duced its ADwin-X-A20, a compact data acquisition and control system. It offers high performance, a dual-core, 64-bit processor, as well as analog and digital inputs and outputs, and a 1 GB
blocks as inputs/outputs; one low- latency trigger input; LS-bus for low- speed discrete I/O expansion; and a rugged metal case with optional DIN rail mounting. In addition, there are a number
ADwin-X-A20 data acquisition and control system.
Ethernet communications interface to provide extremely precise, low-laten- cy, real-time operation. Programs can be created quickly using either the user-friendly ADbasic development environment or through Simulink via the ADsim interface. Features
include: XILINK
ZYNQ ARM Cortex-A9 666 MHz CPU, 64-bit FPU, and 1 GB DRAM; eight 18-bit analog outputs; two low- speed 12-bit analog outputs; eight TTL digital channels configurable in
of options that allow the ADwin-X- A20 to be customized for specific proj- ects and OEM applications, including: eight synchronous analog inputs; 32- bit high-speed up/down and PWM counters; SSI interface; up to 32 digi- tal channels; CAN, RS-232, Profibus, and EtherCAT interfaces; and a boot- loader for standalone operation. The system is designed for such
applications as high-speed and closed-loop control, signal genera- tion, test stand data acquisition, hardware in the loop (HIL) simula- tion and testing, and portable data collection. The device is excellent for projects that require a compact,
high-performance system. Contact: CAS DataLoggers, 8427 Mayfield Road, Unit 104,
Chesterland, OH 44026 % 440-729-2570 E-mail:
sales@dataloggerinc.com Web:
www.dataloggerinc.com
Yamaichi Intros ICT Spring Probe Pins
Aschheim-Dornach, Germany — Yamaichi is now offering spring probe pins for in-circuit test (ICT) with pitches of 0.1 in. (2.54 mm). The company is able to manufacture nearly all geometric shapes in-house. Currently, there are more than 30 different plunger tips available. All pins are compatible with existing receptacles on the market. Yamaichi Electronics is a
provider of test and burn-in sockets, connectors and connection systems. The company offers high-quality,
reliable components for demanding applications in various fields, includ- ing the semiconductor, industrial automation, automotive, data net- working, test and measurement, medical, mobile computing, embed-
ded computing, and other markets. Contact: Yamaichi Electronics
Deutschland GmbH, Concor Park, Bahnhofstrasse 20, 85609
Aschheim-Dornach % +49-89-45109-0 E-mail:
info@yamaichi.de Web:
www.yamaichi.de
Page 135
RoHS
See at IPC APEX, Booth 915
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108 |
Page 109 |
Page 110 |
Page 111 |
Page 112 |
Page 113 |
Page 114 |
Page 115 |
Page 116 |
Page 117 |
Page 118 |
Page 119 |
Page 120 |
Page 121 |
Page 122 |
Page 123 |
Page 124 |
Page 125 |
Page 126 |
Page 127 |
Page 128 |
Page 129 |
Page 130 |
Page 131 |
Page 132 |
Page 133 |
Page 134 |
Page 135 |
Page 136 |
Page 137 |
Page 138 |
Page 139 |
Page 140 |
Page 141 |
Page 142 |
Page 143 |
Page 144