MODULAR FLAME SAFEGUARD CONTROLS
Fireye M-Series II flame safeguard controls are compact, modular burner management systems. They are designed to provide automatic ignition and continuous flame monitoring for commercial burners using gas and/or light oil fuels.
Flame monitoring is accomplished by UV scanners or flame rod detectors and a selection of plug- in amplifier and programming modules which connect into a standard chassis and wiring base. The M-Series controls use the same wiring base as the UVM and TFM-Series models, and are designed to be interchangeable with most of these models without rewiring. Complete M-Series II system consists of chassis, MP programming module, MA amplifier module and UV scanner or flame detector, all ordered separately.
CHASSIS
CAT. NO. MFG. NO. DESCRIPTION 9C325
MC120 Chassis with Dust Cover
VOLTAGE EACH 120
PROGRAMMING MODULES
CAT. NO. MFG. NO. DESCRIPTION 9C327 9C328 9C329
MP100 MP230
9C330 MP560 Relight operation
MP230H Selectable purge timing, trial for ignition timing,and recycle/non-recycle operation; for use with 2-stage burners
USE WITH: EACH MC120
Selectable purge timing, trial for ignition timing,and recycle/non-recycle operation MC120 MC120
Selectable purge timing, pilot trial for ignition, pilot stabilizing period,recycle/non- recycle operation, 10 sec. main flame trial for ignition,run-check switch
AMPLIFIER MODULES
CAT. NO. MFG. NO. DESCRIPTION 9C335 9C336 9C338 9C339
MAUV1
MAUV1T MART1
MART1T
CAT. NO. MFG. NO. USE WITH: EACH 9C103 9C110 9C267
WIRING BASES 60-2060-3
60-1386-2 61-3060
CAT. NO. MFG. NO. DESCRIPTION 9C127
60-1765
E100, E110 E100, E110 “M” Series
UV Amplifier, 2-4 sec. FFRT UV Amplifier, 0.8 sec. FFRT
USE WITH SCANNER: EACH UV1A6 UV1A6
Flame Rectification Amplifier, 2-4 sec. FFRT 45CM1 Flame Rectification Amplifier, 0.8 sec. FFRT 45CM1
$193.04 $193.04 $193.04 $193.04
MC120
$399.88 $972.14
$1,066.94 $1,239.32 $908.22
M-Series II
$550.89 $209.88 $129.21
EACH Adapter to replace Honeywell R4795 w/ “M” Series $160.12 FLAME SCANNERS 48PT1/48PT2 45UV3 UV-1A
CAT. NO. MFG. NO. 9C264 9C115 9C265 9C116
UV1A3
48PT2-9007 UV1A6
USES: EACH
25CU6, 25DU4, UVM1-2 $323.48 E100, D10, D30
$531.95 25CU6, 25DU4, UVM1-2 $383.18 45UV5-1009 72DUV
CAT. NO. MFG. NO. DESCRIPTION USED WITH: 9C242 9C243 9C241
4-128-1 4-263-1 61-326
SCANNER PARTS Firetron Cell
Firetron Cell Lens Cap
48PT1 48PT2
48PT1, 48PT2 $2,485.50
When working on boilers with switching relays, more than one source of power may be connected to the boiler. All sources may not be routed thru the equipment service switch. Simply turning off the service switch may not remove all electric power to the equipment. Should a relay be connected to an alternative power source and activate while the service switch is turned off, the service technician could be subjected to the alternate electrical power, and or equipment operation during service. Always check all external and internal mount- ed relays for power; after the service switch to the equipment has been turned off, and prior to servicing the equipment to avoid potential personal injury.
In instances where alternative source power is detected, reasonable effort should be made to divert all power to the equipment thru the equipment service switch. Should this not be possible at the time, the owner must be made aware of the situation and a future service call to correct the problem should be scheduled. NEC and all building codes require single source power to the equipment.
EACH
$691.26 $431.29 $238.76