Y8610 Series
RETROFIT INTERMITTENT PILOT GAS BURNER IGNITION SYSTEMS
Complete kit for conversion of conventional 24 volt standing pilot systems to electronic intermittent pilot ignition on gas-fired atmospheric furnaces, boilers and heating appliances. Easily installed retrofit package includes S8610 intermit- tent ignition module, dual valve combination gas control, ignitor/sensor assem- bly, ground rod, wiring harness and installation hardware.
REPLACEMENT COMPONENTS for Y8610 Series Ignition Systems
CAT. NO. MFG. NO. 392431 DESCRIPTION Ignitor/Sensor Assembly EACH
2C560U S8610U3009 Intermittent Ignition Module $245.43 2C518
$97.49
2C513U - Non-100% safety shutoff, natural or LP gas. Continuous trial for igni- tion pilot lights or system is shut down manually. 2C529U - Natural or LP gas. Universal retrofit kit, provides 90 second maximum trial for ignition, 100% pilot gas shutoff and system lockout if pilot fails to light.
CAT. NO. MFG. NO. CAPACITY BTUH
2C513U Y8610U4001 150000 2C529U Y8610U6006 270000
GAS CONTROL MODULE
GAS VALVE SIZE (INLET x OUTLET)
Nat/LP S8610U3009 VR8204A2142 1/2 x 1/2” Nat./LP S8610U3009 VR8304M3558 3/4 x 3/4”
EACH
$344.58 $449.54
S9200U Series HSI UNIVERSAL INTEGRATED FURNACE CONTROL
The S9200U is a universal control designed for use as service truck stock. This IFC comes com- plete with molex plug-in harnesses to allow this single control to replace 100+ OEM controls. The S9200U provides 120v main burner ignition, flame rectification, pressure switch monitoring, limit switch and roll out function monitoring, control of system blower with selectable delays, induced draft blower control, LED system sta- tus and diagnostics, and in EnviraCOM enabled. Control has EAC and HUM terminals with twinning option. Ithe IFC is packaged with a number of molex wiring harnesses. Each OEM control has a specific wiring harness assigned for use, in the replacement instructions, to allow ease of use.
CAT. NO. MFG. NO. 2C561U LINE VOLTAGE LOW VOLTAGE S9200U1000 120 Vac HEAT FAN ON DELAY Selectable 30, 90, 120 or 180 seconds
SELECTABLE TRIAL FOR IGNITION
24 Vac @ 0.05 amp 4, 6 or 8 seconds
HEAT FAN OFF DELAY Selectable 30 or 60 seconds
POSTPURGE FLAME FAILURE RESPONSE 2 seconds
15 seconds
COOL FAN ON DELAY Selectable 0 or 60 seconds
FUSED AMPS EACH 3
COOL FAN OFF DELAY 5 seconds
$215.27
MANUFACTURER United Technologies Rheem/Robertshaw Nordyne
Texas Instruments York
S9200U1000 REPLACES THESE INTEGRATED FURNACE CONTROLS REPLACES:
1012-925A, 1012-925B, 1012-925C, 1012-955A, 1012955A, 1012-83-9651B, 1012-930, 1012933D, 1012-933D, 1012-83-9336AHSC1, 1012-83-9337A 62-24268-01, 62-24268-02, 62-24268-03, 695-200
624557, 6245570, 624557-0, 624564, 6245640, 624591, 624591A, 624591-A, 624591-B, 624591-C, 624591-D, 624628, 624628-0, 6246310, 624631-0, 624631A, 624631-A, 624631-B, 710128A, 902378, 902696, 903106, CAR903106 6DT-1, 6DT-2, 61F3, 41F-5
03100662000, 031-00662-000, 031-00662-700, 031-01140-000, 031-01140-001, 031011140002, 031-01140-002, 031-01140-701, 031-01140-702, 031.01234.000, 031-01234-700, 0310123500, 031-01235-700, 031-01250-000, 03101266000, 0310126700, 031-01267-000, 031-01267-001, 031-01267-001A, 031-01284-000, 03101933000, 031-01933-000, 031-01972-000, 031-01973-000, 031-02166-000, 03109166000, 03109167000, 33101933000, 331-01933-000, 33109167000, 331-01972-200, 43101972100, 431-01972-100, P03101267001, P031-01267-001, P031-01267-001, PTH031011400-00, CAR33101972200, CAR03101973000, CAR50A55843, G951ADB1401, G951ADB1401C, G951ADB-1401C, G951ADB1402, G951ADB-1402, G951AEB-1403
White-Rodgers Goodman
ICM 50T35-743, 50A55-120, 50A55-143, 50A55-285, 50A55-288, 50A55-438, 50A55-(474-571), 50A55-843, 50A50-143, 50A50-285, 50A50-286, 50A50-438
1809913, 18099-13S, B180996, B1809906, B18099-6, B18099-06, B1809908, B18099-08, B1809910, B18099-10, B18009910, B180099-10, B1809913, B18099-13, B1809913S, B18099-13S, B18009913, B180099-13, CARB1809913S ICM280
Visit us at www.remichel.com
747
CONTROLS