Spring Loaded Hex Fitting Thermocouple and Thermowell
Series 100: Style ‘L’
Style L spring loaded sensor is ideal for mating sensors and thermowells to virtually any connection head or transmitter assembly. The stainless steel spring loaded fitting insures firm sensor contact with the well for faster time response and vibration resistance. The long lead wires fit even the largest connection head.
K
Length codes X = Sheath length Y = Lead wire length N = Extension length A = Well bore depth U = Well immersion length T = Well lag length
Equations
For threaded & socket wells X = OAL - 1.5 X = N + A A =U + T + 1.5 X = N + U + T + 1.5
For flanged wells X = OAL - 1.5 X = N + A A =U + T + 2 X = N + U + T + 2