W7459 Solid State Economizer Logic Module are used with M7415 and M8405 Dedicated Economizer Actuators to proportion outdoor and return air dampers in economizer systems.
FeATureS
• Attaches to one side of actuator for proportional control of damper.
• Combines solid state changeover control, minimum damper position potentiometer and compressor staging relays.
• Use one sensor in outdoor air for single sensor control; use two sensors, one in return air and one in outdoor air, for differential control.
Item Input
W7459A1001 Y1 and Y2 from thermostat; Discharge Air Temperature: C7150 or C7046 Sensor; Enthalpy: C7400 Sensor
G W7459A1035
See comments; Y1 and Y2 from thermostat
output
Output for M7415
Output for M7415
use with Sensor
C7400; C7150;
C7046; C7650
C7400; C7150;
C7046; C7650 Descriptions
Economizer Logic Module (works with M7415 Damper Actuators)
Economizer Logic Module (works with M7415 Damper Actuators)
Comments
Economizer Logic Module. Optional remote minimum position potentiometer
Economizer Logic Module. With resistor jumper to allow operation with a temp. activated switch to limit min. pos. to 50% max. open. Optional remote minimum position potentiometer.
W7459C1007 Discharge Air Temperature: T675 or T6031
W7459D1005 Y1 and Y2 from thermostat; Discharge Air Temperature: C7150 or C7046 Sensor; Enthalpy: C7400 Sensor
Output for M7415
Output for M7415
C7400; C7150;
C7046; C7650
C7400; C7150;
C7046; C7650
Economizer Logic Module (works with M8405 Damper Actuator)
Economizer Logic Module (works with M7415 Damper Actuators)
Economizer Logic Module.
Economizer Logic Module. High enthalpy limit.
used With
M7415 Damper Actuator
M7415 Damper Actuator
M8405 Damper Actuator
M7415 Damper Actuator
Solid State Economizer Logic Module W7499
Model DeSCrIpTIon
W7459 Solid State Economizer Logic Module with M7415 Actuator to proportion outdoor and return air dampers in economizer systems.
FeATureS
• Combines solid state changeover control, minimum damper position potentiometer and compressor staging relays.
• Use one sensor in outdoor air for single sensor control; use two sensors, one in return air and one in outdoor air, for differential control.
Item use with Sensor
W7499A1003 May add a second C7400 sensor for differential control; C7400; C7150; C7046; C7650
Descriptions
W7459A1001 Economizer Logic Module with M7415A1006 Damper Actuator
Comments
Kit includes W7459A1001 Economizer Logic Module and M7415A1006 Damper Actuator