New 1690MHz VCO from Crystek


Fort Myers, FL — Crystek’s CVCO55CC-1690-1690 VCO (Vol - tage Controlled Oscillator) operates at 1690MHz with a control voltage range of 0.3V to 4.7V. This VCO has a typical phase noise of –120dBc/ Hz@10kHz offset and has excellent linearity. Output power is typically +2.5dBm. Engineered and manufactured


in the USA, the VCO is packaged in the industry-standard 0.5 x 0.5-in. (12.7 x 12.7mm) SMD package. Input voltage is 5V, with a maximum cur- rent consumption of 25mA. Pulling and Pushing are minimized to 1.0MHz and 0.5MHz/V, respectively. Second harmonic suppression is –15dBc typical. The CVCO55CC-1690-1690 is


suitable for use in applications such as digital radio equipment, fixed


wireless access, satellite communica- tions systems, and base stations.


1690MHz VCO. Contact: Crystek Corporation,


12730 Commonwealth Drive, Ft. Myers, FL 33913 % 800-237-3061 or 239-561-3311 fax: 239-561-1025 E-mail: sales@crystek.com Web: www.crystek.com.


Middletown, PA — Phoenix Contact has expanded its M12 connector line for power transmission in industrial environments with S-coded flush- type connectors and cordsets rated to 16A and 630V. (Ratings are per IEC; UL 2237 is pending.) Standard S- coded connectors, rated to 12A, are also available. The connectors have two posi-


Abreath offresh air in gross leak testing


tions and protective earth ground (2+PE). The panel-mount connectors are pre-assembled with 0.5m long wires with conductor cross section of 1.5mm2 (16 AWG). This M12 circular connector system is suitable for use as a main power connector, with IP67 protection and the robust metal M16 X 1.5 panel-mount thread. The compact panel-mount con-


nectors are available in pin and sock- et versions for front and rear mount- ing. The unshielded cable cordsets are available in lengths of 1, 2, 5 and


16Amp Mini M12 Connector from Phoenix Contact


10m, with both straight and right- angle heads. Both male and female pigtail versions are offered as stan-


Mini M12 connectors. dard articles. Double-ended cordsets


can be manufactured on request. Contact: Phoenix Contact, Inc.,


586 Fulling Mill Road, Middletown, PA 17057 % 800-322-3225 or 717-944-1300 fax: 717-944-1625 E-mail: info@phoenixcon.com Web: www.phoenixcontact.com www.phoenixcontact.com


Schurter: Power Entry Modules for V-Lock


No more helium, fluorocarbons, or radioactive gases. Norcom 410 finds gross leaks fast with air pressure alone.


Fast, simple, clean and safe, the NorCom 410 is the all-electronic alternative to bubble leak testing. In seconds, it accurately detects open packages and gross leaks. In minutes, it reports actual leak rates. All without consumables, radioactive gases, or pollutants.


Call for a demonstration on your metal, ceramic, silcone, or glass-lidded devices and discover a fresh approach to leak testing.


610-592-0167 www.norcomsystemsinc.com


1055West Germantown Pike Norristown, PA 19403 USA


Santa Rosa, CA — Schurter has intro- duced its compact KFA and DA22 series power entry modules, with mat- ing V-Lock cord sets. The modules’ new V-Lock compatible feature pre- vents unintended disconnection of the power from the equipment. No addi- tional costly hardware is necessary to install the cord retaining system. The cord set safely latches into a notch in the plastic housing of the power entry modules. Removing the cord set is eas- ily achieved by depressing the latch. V-Lock power cords are offered in a wide range of cord lengths and coun- try-specific plugs, including NEMA 5- 15 standard hospital grade versions. The KFA and DA22 module fam-


ilies have a C14 inlet, with 1- or 2-pole fuseholder for 5 x 20mm fuses, and standard or low leakage, M5, mains fil- ter. The KFA is available with 4.8 x 0.8mm quick-connect or wire leaded terminals, and the DA22 is designed for PCB mounting. Both units offer screw-on front panel mounting. The KFA also offers a snap-in version. The current rating range is 1 to


10A at 250VAC. Optional voltage selector allows for use in international


markets. The new power entry mod- ules are suitable for use in medical devices, IT and audio equipment where the power to the equipment must withstand mechanical stress on


Power entry module with V-lock.


the cord. Both modules meet IEC 60950 and IEC 60601-1 and are


approved by UL, CSA, VDE and CCC. Contact: Schurter Inc., 447


Aviation Blvd., Santa Rosa, CA 95403 % 800-848-2600 or 707-636-3000 fax: 707-636-3033 E-mail: info@schurterinc.com Web: www.schurter.com


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104