TOC Analysis With Self Check System: It Doesn’t Get Safer!
Maximum operation safety with minimum operation effort and perfect measurement results for unattended 24 hour operation: that’s provided only by the fully integrated Self Check System (SCS) of the multi N/C®
series.
This self-monitoring of the device permanently and automatically controls all the parameters which are important for device safety and quality of the analysis. As an intelligent combination of hardware components and software functions, it ensures the trouble-free operation of the entire analytical system. Parameters, such as gas flows, temperatures, pressures, system tightness, detector status, baseline stability, maintenance intervals etc. are constantly checked.
Thereby the SCS works hand in hand with the auto-protection assembly. This effective measuring gas drying and cleaning, which operates completely without the use of chemical drying agents, is monitored by integrated temperature and pressure sensors. If any tolerance levels are exceeded, the SCS assures an automatical shutdown in or order to protect high-value system components.
Furthermore the automatic gas-leak check avoids scattering of measuring results or false low readings caused by gas leaks or flow fluctuations. This way
TOC/TNb analysis becomes child’s play and system operation even without expert knowledge or experiences is no problem.
With a multi N/C®
you are always on the safe side! MORE INFO. 131
Flexibility Beyond any Limits – multi N/C®
With a multi N/C® analyser the parameters TOC, NPOC, POC, TC,
TIC and TNb can be measured quickly, easily and without any conversion. This is
possible thanks to the perfect combination of an efficient sample digestion technology, VITA® Management System and Focus Radiation NDIR
Flow
detector. TOC and TNb are measured truly simultaneously, with a single injection and without any exchange of catalyst or method. A chemiluminescence detector (CLD) or a solid state chemodetector (ChD) ensure quantitative and reliable measurement of all organic and inorganic nitrogen compounds. With variable injection techniques suitable for most diverse sample volumes and with an intelligent rinsing technique, there are no compromises for particle containing samples. Due to temperatures of up to 1300 °C and sample amounts of up to 3 g, the solids module HT 1300 guarantees representative TOC measurement results, even in samples with a low level of homogeneity. And the worldwide unique double furnace technology offers a supplementary alternative for solids analysis.
MORE INFO. 132
Eliminating Running Costs High quality TOC analysis has never been
as affordable!
The price conscious user mainly looks out for overheads when considering TOC analysis. Low- maintenance technologies for sample digestion, an environment-friendly low consumption of operating materials such as gas and power, as well as robust device engineering with a long service life help to keep the costs low. All this is offered by the TOC analysers of the multi N/C®
series! And there is more... The multi N/C® devices are equipped with state-of-the-
art digestion technology, which is characterised by an extremely low consumption of catalyst material and exceptionally long lifetimes of the combustion tube – especially for extreme matrices. The corrosion-proof Focus Radiation NDIR detector ensures reliable results and high stability – across the whole lifetime of a device. Additionally a long-lasting calibration – enabled by the patented VITA®
effort for maintenance and care of the device is reduced to a minimum. This is how the TOC analyser can eliminate overheads in your lab.
Low running costs – full performance! MORE INFO. 133 MORE INFO. 134
Nothing is Impossible: TOC Determination Without Ifs and Buts
Difficult TOC samples are no longer a problem with a device of the multi N/C®
series,
equipped with special digestion and detection technology.
Thanks to their robust high-temperature reactor, no matrix is too extreme and no salt content is too high for the multi N/C®
series. At the same time, these all-rounders are extremely
economical! This is also due to the high lifetimes of the digestion reactors as well as the maintenance-free, sensitive and robust Focus Radiation NDIR detector and the low running costs. Whether it is particles, salt or low sample volumes – the multi N/C®
series handles the most
complicated TOC/TNb applications, which usually require expensive extras, with its standard equipment.
Test the device you have always been dreaming of: Test the multi N/C® series. MORE INFO. 130
method – and the daily
INTERNATIONAL LABMATE - JANUARY/FEBRUARY 2013 - ADVERTORIAL
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96