Chromatography 17 References
1. J.S. Medina, R. Prosmiti, P. Villarreal, G. Delgado-Barrio, G. Winter, B. González, J.V. Alemán, C. Collado, Chem. Phys., 388 (2011) 9-18 2. D.A. Andrade, Viscosity and Plasticity, W. Heffner & Sons, Cambridge, 1947. 3. T. Teutenberg, S. Wiese, P. Wagner, J. Gmehling, J. Chrom. A, 1216 (2009) 8470-8479 4. L. Dagdug, L.S. García-Colín, Physica A: Statistical Mechanics and its Applications, 250 (1998) 133-141 5. George S. Fanourgakis, J. S. Medina , and R. Prosmiti J. Phys. Chem. A, 2012, 116 (10), 2564–2570 6. S. Heinisch, G. Desmet, D. Clicq, J-L. Rocca, J. Chrom. A, 1203 (2008) 124–136 7. J.J. van Deemter, F.J. Zuiderweg, A. Klinkenberg, Chem. Eng. Sci., 1956, 5, 271 8. D. Brogioli and A. Vailati, Phys. Rev. E 63, 012105/1-4 (2001) 9. F. Gritti, Chrom. Today, 5(2) (2012) 4-11 10. J. H. Knox, J. Chrom. A, 831, 1, (1999), 3-15 11. K. Miyabe, G. Guiochon, J. Chrom. A, 961, 1, (2002), 23-33 12. F. Gritti, I. Leonardis, J. Abia, G. Guiochon, J. Chrom. A, 1217, 24 (2010) 3819-3843 13. J. Haun, K. Oeste, T. Teutenberg, T.C. Schmidt, J. Chrom A, 1263 (2012) 99– 107 14. J.C. Giddings, J. Chrom. A, 3 (1960) 443-453 15. H.A. Claessens, M A. van Straten, J.J. Kirkland, J. Chrom. A, 728, 1–2 (1996) 259-270 16. H.A. Claessens, M A. van Straten, J. Chrom. A, 1060, 1–2 (2004) 23-41 17. A.M. Edge, I.D. Wilson, S. Shillingford, Chromatographia 66 (2007) 831 18. M. Koel, M. R. Kaliurand, M. Koel, Green Analytical Chemistry pub RSC (2010) chapter5 19. J.J. Pesek, M.T. Matyska, J. Chrom. A, 952, 1–2, (2002) 1-11 20. R, Trones, A. Tangen, W. Lund, T. Greibrokk, J. Chrom. A, 835, 1–2 (1999) 105-112 21. Y. Xiang, B. Yan, B. Yue, C.V. McNeff, P.W. Carr, M.L. Lee, J. Chrom. A, 983, 1–2 (2003) 83-89 22. R.E. Paproski, C. Liang, C A. Lucy, J. Chrom. A, 1218, 44 (2011) 7948-7955 23. J.H. Knox, B. Kaur, G.R. Millward, J. Chrom. A, 352, 21 (1986) 3-25
24. Karen Gaudin, Pascal Millet, Fawaz Fawaz, Piero Olliaro, Nicholas J. White, Céline Cassus-Coussère, Ulrich Agbahoungha, Jean-Pierre Dubost, J. Chrom. A, 1217, 1 (2010) 75-81
25. C. West, E. Lesellier, J. Chrom. A, 1087, 1–2 (2005) 64-76 26. L. Pereira, S. Aspey, H. Ritchie, J Sep Sci. 8 (2007) 1115-24. 27. J. Volden, Y. Thomassen, T. Greibrokk, S. Thorud, P. Molander, Analytica Chimica Acta, 530, 2 (2005) 263-271 28. V.V. Korshak, V.A. Khomutov,
Yu.Ye. Doroshenko, Polymer Science U.S.S.R., 18, 3 (1976) 597-603 29. J.D. Thompson, P.W. Carr, Anal. Chem., 2002, 74 (5), 1017–1023 30. S. Heinisch, J-L. Rocca, J. Chrom. A, 1216, 4 (2009) 642-658 31. D. Guillarme, S. Heinisch, J.Y. Gauvrit, P. Lanteri, J.L. Rocca, J. Chrom. A, 1078, 1–2 (2005) 22-27
Figure 7. An example of a separation on a Hypercarb 5µm 100 x 4.6mm using a thermal gradient and water as the mobile phase. Separation was performed on a Hypercab column, with water as the mobile phase,
flow rate 2 mLs/min., temperature gradient 150 to 200°C, separating cytosine, uracil (1), thymine (2), hypoxanthine (3), guanine (4), xanthine (5).
32. J.S.B. de Vlieger, M.J.N. Giezen, D. Falck, C. Tump, F. van Heuveln, M. Giera, J. Kool, H. Lingeman, J. Wieling, M. Honing, H. Irth, Wilfried M.A. Niessen, Analytica Chimica Acta, 698, 1–2, (2011) 69-76 33. S. Wiese, T. Teutenberg, T. C. Schmidt, J. Chrom. A, 1222 (2012) 71– 80 34. A.M. Edge, S. Shillingford, C. Smith, R. Payne, I.D. Wilson
J.Chromatogr. A 1132, (2006) 206 35. A. Hazotte, D. Libong, P. Chaminade, J. Chrom. A, 1140, 1–2 (2007) 131-139 36. T. Greibrokk, T. Andersen J. Chromatogr. A 1000 (2003) 743 37. H. Gika, G. Theodoridis, J. Extance, A.M. Edge, I.D. Wilson J. Chromatogr. B 871 (2008) 279 38.T. Teutenberg, Anal. Chim. Acta 643 (2009) 1
Parallel Sample Preparation System for HPLC Vials
Porvair Sciences has announced a new version of its MiniVap™ Blowdown Evaporator able to quickly and safely remove solvent from up to 48 vials in parallel.
Made from solvent resistant black polypropylene the new MiniVap Vial Holder has been designed to accommodate up to 48 vials in a standard SLAS / ANSI format.
Incorporating advanced evaporator head technology which directly injects heated nitrogen into 48 HPLC |vials simultaneously, the MiniVap removes the traditional laboratory ‘bottleneck’ of solvent evaporation from vials.
The MiniVap™ Blowdown Evaporator takes just minutes to remove volatile organic solvents from your samples collected in 24- or 96-well microplates and now HPLC vials.
Compact in design the affordably priced MiniVap™ is simple to install, operate and maintain. Installation just requires connection to a gas supply and standard mains socket. Safety of operation is ensured as the CE marked compact unit fits into all fume cupboards.
MORE INFO. 33
Interested in publishing a Technical Article?
Contact Gwyneth on +44 (0)1727 855574 or email:
gwyneth@intlabmate.com MORE INFO. 34
INTERNATIONAL LABMATE - JANUARY/FEBRUARY 2013
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96