Spotlight Ovens, Incubators & Sterilising


Safety First with new Compact Shield for Stirrer Hotplates


Asynt’s Compact Lab Safety Shield fits neatly around any stirrer hotplate to provide robust, convenient protection from splashes, aerosols and spills. Ideal for use where fume hood space is at a premium, the Safety Shield offers additional protection for chemists in the event of a tube or cap failure under pressure, even if the fume hood sash is raised.


Manufactured from 5mm polycarbonate, the Safety Shield is resistant to a range of commonly- used laboratory solvents and is temperature- resistant to 170ºC. Designed with a small footprint to maximise fume hood space, the shield maintains access to hotplate controls and gives good all-round visibility of the reaction or process.


In addition to giving essential protection in applications such as heated parallel reactions in tubes, especially those operating under pressure, the device also shields reactions from the cooling effect of ventilation.


Manufactured in the UK, this is the only compact safety shield available for under £100, which fits Asynt, IKA and Heidolph stirrer hotplates.


Circle no. 87 ADVERTORIAL Cooled Incubators Series 3 -10˚C +50˚C


Specialist in Cooled Incubation


Our aim is to be flexible, to provide the cabinet which meets your application.


With a full range of optional extras to suit your requirements


Temperature Range -10°C to +50°C


Capacity 76 - 1200 litre


The LMS Series Three Cooled Incubator is a reliable and accurate temperature controlled cabinet (-10°C to +50°C) which has proved its worth over many years in laboratories both in the U.K. and overseas.


The design of the purpose built incubator facilities the addition of optional extras to provide greater flexibility for individual use, making it suitable for a wide range of applications including:-


• The study of growth patterns of plants and insects • B.O.D. Tests


• Seed germination & vernalisation • Tissue culture • Enzyme testing • Serum studies • Immunology • Fruit fly culture • Sample storage • Product shelf life tests


Circle no. 89 Series 1A Cooled Incubators


The LMS Series ‘1A’ Cooled Incubator is a reliable and accurate Temperature controlled cabinet (-10°C to +50°C) designed for optimum performance and reliability. The design of the purpose built incubator facilitates the addition of optional extras to provide greater flexibility for individual use, making it suitable for a wide range of applications.


Circle no. 90 Kit To Assist in Detection of Endogenous Peptides


Denator AB announced that it has launched the first in a series of kits designed for use with the company’s heat-stabilisation system. The Stabilizor™ Peptide Extraction Kit enables users to heat-stabilise, homogenise and extract endogenous peptides from tissue samples prior to analysis by liquid chromatography-mass spectrometry (LC-MS).


During downstream analysis, the presence of endogenous peptides, often existing at very low levels in vivo, can be masked by peptide fragments generated from normal degradation processes. Utilisation of Denator’s Stabilizor system, based on the company’s heat-stabilisation technology, has been shown to stop tissue degradation from the moment of sampling, preventing the enzymatic processes that generate peptide fragments.


This news will be of particular interest to researchers looking at the role of neuropeptides in neurogenerative diseases. A recently published paper demonstrated an increased recovery of neuropeptides from tissue samples when utilising heat stabilisation followed by an optimal extraction protocol (Neuropeptide profiling of the bovine hypothalamus: Thermal stabilisation is an effective tool in inhibiting post-mortem degradation.


Olof Sköld, CEO at Denator, explained further: “Working closely with users of our system has revealed that the quality of final results can be influenced by the extraction methods used after heat stabilisation.


This new kit offers the convenience of having all necessary accessories and solutions ready to use, and, most importantly, includes a validated protocol that aims to maximise the recovery of endogenous, water-soluble peptides for subsequent analysis by LC-MS. We see this development as a natural step to ensure that researchers who heat-stabilise tissues upstream achieve the best possible analytical results downstream.”


Implementation of the Stabilizor solution in laboratory workflows is reflected in a growing number of peer- reviewed publications particularly from proteomic laboratories. Scientists are able to perform many analyses without risk of sample degradation, confident that their results truly reflect the in vivo situation.


Circle no. 88


www.lms.ltd.uk sales@lms.ltd.uk


Circle no. 91


We can Now Offer a Bespoke Range of Cabinets for you to choose the Size, Volume, Layout, Specification and Material Finish


Circle no. 92


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68