DESCRIPTION The EURO366G Vibraswitch malfunction detector provides maximum protection from rotating and reciprocating of large motors, pumps or compressors. It is intended for indoor or outdoor use in hazardous or non-hazardous areas with ATEX and CE certifications.
FEATURES
• Flame Proof (Explosion Proof ) • Does not require any form of external power to operate. • Measures total destructive shock, not displacement. • No moving parts except when set-point is exceeded. • Instrument is rugged and durable - no wearing parts. • Reset Manual at unit and choice of remote electrical. • AC or DC Reset coil options
• IP66 Cast Iron Enclosure for outdoor and indoor use.
1. 3/4" UNI opening will also accept 3/4" NPT fittings. 2. Plug may be discarded if not required.
4. Space heaters are intended to prevent condensation in the enclosure where climate conditions require. Space heaters are not required in most applications. Cast Iron EN-GJL200
Flame (Explosion) proof EEx-d-IIB/C-T6 IP66 T85° C CESI 03 ATEX 186 IP66 Standard
2 x 3/4" UNI 6125-74 (will accept 3/4 NPT fitting)
-20° C to +40° C (Standard), (Anti-condense painted into enclosure) -40° C to +60° C (Optional) To 95% relative humidity @ 37.7° C (100° F) 40 g @ 11 ms maximum
0 to 4.5 g from 0 to 300 Hz 0 to 3.5 g from 0 to 300 Hz 1 turn per g
± 5% of full range from 0 to 300 Hz ± 10%/55.5° C (132° F) maximum
4 minutes ON max, 10 minutes OFF min 1 minute ON max, 10 minutes OFF min