Vibration Malfunction Detection Switches Model 368 Vibraswitch
DESCRIPTION
The 368 pneumatically operated vibraswitch constitutes the most effictive known method of avoiding costly damage due to mechanical malfunction of rotating and reciprocating machinery where air is the operating control medium.
FEATURES • Acceleration sensitive measures total destructive shock • 15 psig to 50 psig supply pressure • Adjustable set point range 0G to 4.5G • NEMA 4 weatherproof enclosure • Local manual or remote pneumatic reset • Suitable for hazardous areas • 20 psi output alaram
SPECIFICATIONS Inlet Pressure
Control Pressure Reset Pressure Setpoint Range Accuracy Shock
System Operating Conditions: Reset - No Flow Cover Enclosure Materials Base Enclosure Materials Locations used in
15-50 psig
(Tripped) 3 psig nominal 15-50 psig
0-4.5 g (peak), adjustable 1 g per turn
± 5% of full range at frequencies 0 to 300 Hz 40 g @11 ms maximum
Tripped - 0.266 SCFM @ 20 psig High impact, ABS Thermoplastic Type 360 (Cu Free) Aluminum