CASE STUDIES
Cooltherm equips Cardiff university with high efficiency Mitsubishi chiller
A chiller replacement project for Cardiff University will massively reduce the carbon footprint of process cooling, resulting in important energy cost savings.
T
he Cooltherm team in Wales was selected to design a bespoke full turn-key chiller plant to provide the university with the most efficient and low carbon system as possible.
Cooltherm’s project team back engineered the existing system and regrouped all the data to ensure the design was as efficient as possible, as well as maximising the performance of the system. The chiller was feeding thirteen indoor fan coil units located within the third-floor laboratories, as well as an air handling unit cooling coil. The maximum cooling capacity was proven to be 50kW at +6/ +12oC flow and return water conditions. The existing pump was undersized which proved to be the cause of past water issues. Cooltherm designed a new pump skid comprising two Lowara Run and Standby pumps to suit the maximum required flow rate and pressure loss through the existing hydraulic circuit. To increase the performance, each pump is inverter driven and is controlled depending on the instantaneous
74 June 2017
cooling demand ensuring the right flow rate through the chiller and the minimum power consumption.
Romain Pernet, Cooltherm’s projects supervisor, said: “This project combined a high level of engineering with very high performance. Project management was a crucial aspect of the job, and everything from the crane lift to commissioning was organised and well prepared. The client was really happy with the outcome and is planning to install another similar system within the university. In fact, a second E-Series chiller has already been delivered and we are looking to install more”. The Mitsubishi E-Series chiller uses highly efficient scroll compressor technology using only 5% of a conventional chiller starting current, equipped with a soft-start device. The starting current of 8Amps is the key fixture of the low carbon emission machine. A conventional chiller in comparison would have an average starting current of 180A, it is anticipated that this will save the university £4,000 a year on energy costs.
www.acr-news.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108 |
Page 109 |
Page 110 |
Page 111 |
Page 112 |
Page 113 |
Page 114 |
Page 115 |
Page 116 |
Page 117 |
Page 118 |
Page 119 |
Page 120