Environmental analysis of water samples is often an underappreciated aspect of monitoring or processing infrastructure. It certainly isn’t easy: whether it’s checking for pollutants in a river or the quality of drinking water, water samples frequently have complicated, dirty matrices. They can foul up instruments, requiring downtime to clean ion sources, and often have heavy co-elution of analytes, making identifi cation diffi cult at best. While many countries have regulations in place to maintain safe levels of various chemicals, no written list can contain every last signal that might be concerning. Where can you start if you don’t even know what you’re looking for?
Gas Chromatography (GC) coupled with Time-of-Flight Mass Spectrometry (TOFMS) is an excellent tool for water analyses. With TOFMS, the ions’ mass-to-charge ratio (m/z) is determined via time measurement. The fi rst TOFMS was developed in the 1950s, by Dow, and as the technology has been refi ned, the popularity and usefulness of this technique has grown. With TOFMS, one sample run results in the full mass range data, with no compromises needed in acquisition rates. In addition, there is no spectral skewing with changes of analyte concentration, unlike with scanning mass spectrometers like quadrupoles.
These two advantages allow a suffi cient number of high quality mass spectral data points to be collected across even very narrow peaks, regardless of concentration, which is vital for accurate and reliable deconvolution to occur. It allows both Target Analysis and Non- Target Screening to occur simultaneously, enabling additional investigation, perhaps to monitor trends and patterns in the types and levels of other chemicals. Since all of the data is already collected, this also allows a historical record to be built up, so if a new contaminant is discovered, for example, previous samples can be checked to see when it started appearing.
Using a GC-TOFMS with an open ion source is another way to ease some strain on your analyses: an open ion source minimises the interaction of sample ions with the surfaces of the instrument, eliminating the need for cleaning.
This is especially useful when combined with hydrogen as the carrier gas, which is frequently seen as problematic for robustness and mass spectral continuity with typical ion source designs. An open ion source design in your instrument eliminates that concern entirely.
Figure 2. A comparison of chromatograms for the same sample run with helium and hydrogen carrier gases and a close-up of trichlorophenol with helium and hydrogen carrier gases. Chromatogram 1 shows helium carrier gas and a run time of more than 30 minutes with a resolution of 1.66. The library match confi dence is 941. Chromatogram 2 shows the same sample run with a direct method transfer to hydrogen carrier gas. The run time has dropped to less than 10 minutes with a resolution of 1.58 and a library match confi dence of 935. Chromatogram 3 uses the same sample with the method optimised for speed. The run time is now less than 8 minutes, and the resolution is 1.51.
Figure 1. A comparison of TOFMS and Scanning MS chromatograms over the entire GC peak width. As the analyte concentration changes, the mass spectra remains consistent with TOFMS.
TOFMS provides more than just quality data: it can provide quality data quickly and cheaply. Depending on the instrument chosen, GC-TOFMS can be set up to run with hydrogen as a carrier gas instead of helium. This is much more budget-friendly with the rising cost of helium, and it doesn’t take much of an initial investment.
Method transfers can be handled easily with online tools, and by swapping out the column for a narrower, shorter one, the same sort of spectral resolution can be obtained in a fraction of the time.
Even with all the benefi ts of GC-TOFMS, sometimes it isn’t enough for challenging water matrices. This is where GCxGC comes into play as an additional tool for your laboratory. The original two-dimensional GC was called ‘Heart-Cut’ chromatography, where just a specifi c portion of the effl uent from one column is diverted to a different column for a wide-peaked slice of additional information. However, true comprehensive GCxGC traps the entire effl uent from the fi rst column with a modulator, which then re-injects the entire sample into a secondary column for a huge increase in chromatographic peak capacity and increased sensitivity. Various modulators can change the level of results you can obtain, allowing you to customise your instrument to your budget, but in all cases, using GCxGC- TOFMS results in improved deconvolution and more confi dence in your samples.
The tools of TOFMS don’t stop with comprehensive two-dimensional GCxGC analysis. As the name Time-of-Flight implies, the fl ight time is very important to TOFMS. The longer the ions’ fl ight path is, the higher the resolution of the spectral results can be. High Resolution TOFMS (HR-TOFMS) is actually possible with innovative techniques such as a folded fl ight path using gridless mirrors and periodic ion lenses to refl ect the ions back and forth, leading to mass resolution modes of 25,000 or 50,000. HR-TOFMS can be done with both one-dimensional GC or comprehensive GCxGC analyses.
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68