How to Accurately Analyse Viscous Substances Using IR Spectroscopy
Infrared spectroscopy of some liquids is best accomplished in transmission mode, where the whole sample is exposed to the path of the infrared beam. The advantages over ATR include higher sensitivity and accurate determination of pathlength – essential for accurate quantitation.
Traditional liquid transmission cells are simple in construction, consisting of no more than two IR transmitting windows and a thin spacer clamped together with backing plates. Although simple by design, their use can be complicated by viscous samples which may stick or apply unevenly to the windows.
These same samples are also difficult to introduce and clean from a cell, requiring careful reassembly after each sample. This makes accurate and repeatable control of the pathlength near impossible.
The Pearl™ liquid transmission accessory holds the innovative horizontally mounted Oyster™ cell, consisting of two precision machined window holders which match to provide a highly repeatable pathlength without the use of spacers.
New and used motor oils
Service oils are designed to minimise wear-and-tear in engines. Over time the oils pick up elemental metals, soot and other contaminants which visibly spoils the oil. ATR analysis is typically not sensitive enough to pick out the early signs of this degradation, requiring the larger effective pathlength of a transmission measurement to determine.
IR spectral analysis can help determine which contaminants are present, as well as what kind of chemical degradation has occurred in the oil. Traditionally, a vertically mounted cell was the go-to method for loading viscous or sticky fluids. However, this approach leads to problems with sample loading, consistent pathlengths, and cell clean-up.
Figure 1 compares the spectra of fresh and used Castrol Magnatec oil samples using a 25 µm pathlength. Very little sample (< 5 ml), was needed to quickly differentiate the oils. The used sample shows clear evidence that the oil has been chemically altered and presence of contaminants.
Evidence of sulfation is observed by the growth of bands around 1150 cm-1 , while the 1600 – 1700 cm-1
region shows evidence of oxidation and nitration in the oil. There is a loss of relative signal intensity at ca. 1500 and 1460 cm-1
Evaluation of aged transformer oils
Mineral oils are employed as thermal and electrical insulators in many power transformers. Thermal and electrical stress over the lifetime of the transformer results in the chemical breakdown of the oil, which can be monitored using FTIR spectroscopy and principal component analysis (PCA).
These chemical changes are accompanied by changes in physical properties such as viscosity, making consistent and reliable sampling of the oils a challenge. In particular, achieving a consistent pathlength for FTIR analysis becomes challenging. Here the Pearl™ liquid transmission accessory, fitted with an oyster cell™, is advantageous as a consistent pathlength can be easily achieved even for the most viscous of oil samples.
Determining pathlength for standard measurements
In many industries it is common to carry out measurements according to standards published by bodies such as the American Society for Testing and Materials (ASTM) or the German Institute for Standardization (DIN).
A basic requirement of such methods is to determine the pathlength of a transmission cell independently of any nominal pathlength established by the manufacturer.
The Oyster™ cells come in two configurations, one with a parallel window arrangement and another with ‘wedged’ windows, where a very small angle is allowed between the planes of the two windows. Doing so prevents the appearance of so-called ‘fringing’ (or etalon) effects in the spectra recorded with the cell which result from multiple reflections between two parallel windows.
Since the periodicity of the fringing is related to the distance between the two windows, this is the principal method of accurately determining the pathlength of a transmission cell.
From the fringing pattern obtained in an empty cell, the pathlength of the cell can be calculated from the following formula:
P = 5000 n / (ν1 – ν2) Where: P = pathlength in micrometers n = number of fringes ν1 = wavenumber at first peak (in cm-1) ν2 = wavenumber at second peak (in cm-1)
Specac have recently developed a simple software tool for determining the pathlength of Oyster™ cells directly. This is now available for download on the Specac website and is free to use. The software determines the pathlength of parallel cells using the fringing calculation, whilst wedged cells are determined from the absorbance of a standard solvent, n-heptane.
51259pr@reply-direct.com
Figure 2: Example spectrum showing the fringing pattern for a parallel windowed cell. Using the calculation shown above this cell was determined to have a pathlength of 108.5 µm.
Figure 1: A comparison of new & used Castrol Magnatecs. . This is marked by blue circles and indicates a decreased concentration of the original oil in the used sample.
INTERNATIONAL LABMATE - FEBRUARY 2020 - ADVERTORIAL
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88