45 Convenient operation


Thanks to the improved liquid nitrogen duct and electronic monitoring, direct contact of the user with LN2 is virtually impossible. The new CryoMill offers a maximum of operation safety while ensuring low LN2 consumption. The operating interface has become more user-friendly; the clear structure allows for intuitive programming of grinding cycles.


The new product generation features memory for 9 Standard Operating Procedures (SOPs), allowing to carry out routine applications at the push of a button.


Inserting and releasing the grinding jar has become even easier and safer. Wide range of accessories


The screw-top grinding jars of hardened steel and stainless steel have been specifically designed for use in the CryoMill. The fact that no sample material can escape makes them particularly safe. They are available with volumes of 5 ml, 10 ml, 25 ml, 35 ml and 50 ml. For applications where steel jars cannot be used due to possible sample contamination, Retsch offers a 25 ml grinding jar of zirconium oxide and matching grinding balls.


Various adapters make the CryoMill a versatile instrument. If only very small sample amounts need to be processed, an adapter for 2 resp. 4 grinding jars of 5 ml is recommendable. It is also possible to use 2 ml reaction vials with the CryoMill thanks to another adapter which can hold up to 6 tubes.


For safe and comfortable operation of the CryoMill, the unit is equipped with an autofill system for liquid nitrogen which can be obtained with a 50 litre container (for processing approximately 20 to 30 samples). It is also possible to connect existing cryo tanks to the mill.


Summary


For tough and elastic materials as well as for samples which contain volatile components, cryogenic grinding is the only method to obtain the required analytical fineness. The Retsch CryoMill has proven to be the perfect tool for grinding temperature-sensitive materials with a glass point below room temperature. The grind sizes are significantly finer than those produced by comparative mills and have further improved with the new product generation. Especially for difficult materials such as polyethylene or leather the Retsch CryoMill is the ideal instrument for sample preparation.


More information at www.retsch.com/cryomill


New Dimensions in Sample Preparation and Particle Analysis


Launch of a Mechanical Tablet for Routine Checks of Tablet Hardness Tester Functionality


Measuring product breaking force is a standard procedure in every tablet manufacturing facility. Like all instrumentation, regular qualification of a hardness tester is mandatory. In order to ensure that the instrument is functioning within specifications, Sotax has developed the MT, a simple device that is designed for frequent routine verifications of the functionality of tablet hardness testers between qualifications.


Supplier-independent, the MT is designed to work with all hardness testers. The tablets are engineered so that a predetermined amount of force triggers a mechanical breaking point which is recorded by the hardness tester.


MTs are manufactured at five different breaking forces with an accuracy of ±0.5 Kp or better (5 Kp, 10 Kp, 15 Kp, 20 Kp, 30 Kp). They can also verify six different physical dimensions ± 0.03mm (5mm, 10mm, 14mm, 15mm, 20mm, 30mm).


The devices are all calibrated, verified, and tested according to a strict quality process using a NIST traceable calibration instrument. A full internal test report along with a calibration certificate is provided with each MT.


MORE INFO. 133


Innovative mills, grinders and sieve shakers from RETSCH for neutral-to-analysis and reproducible preparation and characterization of solids.


Zero gravity


Win an extra ordinary adventure or total prizes worth


1o,ooo € www.retsch.com/win


Legal action excluded


Launch of Next-Generation Capillary Electrophoresis (CE) Platform


Beckman Coulter Life Sciences offered products across a range of biotech, analytical chemistry and industrial applications at Pittcon 2013.


One example of new applications is found with the PA 800 plus next-generation capillary electrophoresis (CE) platform, which provides automated, quantitative analysis of protein purity, charge isoform distribution and glycan structure. Originally designed with biopharmaceutical analysis in mind, the system can also be used in food and beverage quality studies for monosaccharide and protein analysis, and in the quantitative characterisation of ions, organic acids and other charged or polar molecules of importance.


MORE INFO. 134


Retsch GmbH · Germany Phone: +49(0)2104/2333-100 Fax: +49(0)2104/2333-199 E-Mail: info@retsch.com


WWW.RETSCH.COM MORE INFO. 135


pure science – no fiction


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68