Simultaneous Enantiomeric Separation of Multiple Beta Blockers Using UltraPerformance Convergence Chromatography
Goal
To demonstrate the simultaneous enantiomeric separation of beta blockers using UltraPerformance Convergence Chromatography™, resulting in time and cost savings compared to traditional normal phase techniques.
Background
Beta blockers, a class of pharmaceuticals, are some of the most widely prescribed drugs. While this class of pharmaceutical compounds is typically present as a racemic mixture, differences in pharmacological activity and potency have been observed for the enantiomers; for example, the S- enantiomer of propanolol is more potent than the R- isomer. These differences may not only affect patient efficacy but may also have an impact on the environment as biodegradation pathways are often enantioselective. This phenomenon has led to the development of a number of simultaneous enantiomeric screening methods for multiple beta blockers under normal phase conditions [1]. Method development for these separations requires the screening of multiple chiral columns because selectivity is most easily manipulated by the choice of the stationary phase. This type of approach is both time-consuming and costly.
Figure 2. Chiral separation for mixture of four beta blockers. Conditions were as follows: 2 mL/min; gradient: 7% to 25%, 20 mM ammonium acetate in Me0H in six minutes, 35 ºC; ABPR: 1500 psi.
Summary
The Solution Waters®
ACQUITY UPC2™ System utilizes compressed CO2 mobile phases to allow for the analysis of chiral pharmaceutical compounds in less time with reduced solvent consumption than traditional
normal phase separations.
Beta blockers, a class of drugs that are typically basic, were screened across multiple columns. The use of CO2 mobile phase allowed for higher linear velocities than those used in traditional normal phase separations. Coupled with a fast gradient and 50-mm columns, the conditions facilitated screening of
six columns in under 30 minutes. Methanol was used as the modifier (co-solvent) for the desired retention, and ammonium acetate was used as the basic additive to achieve the required peak shape. Evaluation of a wide range of chiral columns, as shown in Figure 1, demonstrated that the CHIRALPAK IB-3, 2.1 x 50 mm column provided the highest resolution for the beta blockers enantiomers. All other columns exhibited either a single peak or a partially resolved pair for the majority of the enantiomers.
Enantiomers of pharmaceutical compounds, including beta blockers, have traditionally been analyzed under normal phase conditions. Consequently, analysis of multiple chiral compounds can be time-consuming and require extensive method development. By utilizing the ACQUITY UPC2System in combination with a CHIRALPAK IB-3 2.1 x 100 mm column, analyses consisting of the simultaneous separation of multiple beta blockers can be completed in less than six minutes, resulting in 2x increase in throughput versus comparable normal phase separations [1].
Reference
1. Morante-Zarcero S, Sierra I. Comparative HPLC methods for β-blockers separation using different types of chiral stationary phases in normal phase and polar organic phase elution modes. Analysis of propranolol enantiomers in natural waters. J Pharm Biomed Anal. 2012 Mar 25;62:33-41.
Figure 1. Column screening of beta blockers. Conditions were as follows: columns: 2.1 x 50 mm; gradient: 2% to 20%, 20 mM ammonium acetate in five minutes.
The selected column stationary phase (CHIRALPAK IB, 2.1 x 100 mm) was then used to develop a single assay for multiple beta blockers. A mixture of multiple beta blockers was evaluated under gradient conditions using 20 mM ammonium acetate in methanol as a modifier. These conditions provided no co-elutions of the four beta blockers tested while allowing for retention times of less than seven minutes for all solutes. To improve the selectivity of the separation, the effect of column temperature was evaluated. Based on these observations, a temperature of 35 °C provided the highest resolution for the four beta blockers tested. The resulting separation provided baseline resolution for all of the enantiomers in a single run of less than six minutes.
http://upc2.waters.com MORE INFO. 34
INTERNATIONAL LABMATE - APRIL 2013 - ADVERTORIAL
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68