Water / Wastewater
Another common wireless application for factories or wastewater facilities is monitoring the temperature of the effluent discharge into the river and comparing it to the upstream water temperature. Although the distance from the river edge to the treatment plant is short, often there is no power at either data collection point and wiring can be cost prohibitive compared to the cost of the current wireless technology and temperature sensors.
River and Pond Level Control
Monitoring and controlling river, pond, and lake levels is an ideal example of using wireless technology in areas without access to wired power or data communication.
Radar gauges, encoders, and float systems connected to wireless devices are used to monitor lake levels. The wireless devices translate the level data back to a control center for logging and analysis. Submersible pressure sensors connected to wireless devices are also used to monitor retention pond levels. Level data is transmitted back to central control rooms for analysis to prevent retention ponds from overflowing during rainstorms or releasing the runoff into streams and rivers before it is tested for contaminants.
Landfill Leachate and Biogas Monitoring
Regulatory agencies require landfill operators to measure and monitor the water levels within all ground wells in the landfill site, monitor leachate accumulation and removal, and accurately monitor methane gas production, removal, venting, and burning.
Wireless devices connected with a counter input and submersible pressure sensor/transmitter reliably monitor both the leachate level and the pump. The submersible pressure transmitter monitors the leachate level while the pump strokes used to remove that leachate are counted. The sensor information is wirelessly transmitted to a host system that stores the data, performs calculations, or notifies personnel when a service vehicle is needed at a specific well.
Biogas wellheads equipped with a pressure sensor and wireless EX approved wireless node send back status signals on gas production for each individual well. Negative pressure within the methane production system is monitored and adjusted in real time, increasing efficiency and cost effectiveness. Thermocouples are used on the flare to monitor flame temperature and verify that the combustion of methane is ongoing. The wireless devices connected to both a pressure transducer and the temperature sensors collect the data and wirelessly transmit the data back to a host system for logging and analysis to comply with local, state, and federal regulations.
Compost Temperature Management
To increase the efficiency of composting and ensure proper hygienisation, the temperature of the compost piles is measured and logged constantly through wireless temperature probes equipped with three sensing points.
Using wireless devices increases workplace safety because operators do not need to climb onto the piles several times a week to manually monitor the temperatures. Manually collecting this data is time consuming, introduces errors, and exposes the personnel to harmful pathogens.
Automatically collecting the data using sensors and wirelessly transmitting the data back to a centralized location allows composting temperatures to be continually recorded and logged, improving efficiency and reducing the time needed to complete a composting cycle.
Gas Detection in a Hazardous Environment
In a recent application, a major French gas detection company installed gas detectors on a UK client site to ensure employee safety around the plant and detect any hazardous situation. Due to the facility’s size, running additional wires to the detectors situated far from the control room would have been complex and too expensive.
Instead, they equipped the sensors with a wireless OEM board. With this option, the signal from all detectors can be remotely monitored at all times, effectively protecting the site personnel and limiting the need to enter potentially dangerous areas.
Oil and Gas
Having a precise control of tanks volumes allows operating companies to efficiently coordinate fuel purchases with respect to fuel market fluctuations. It also helps avoid losses and inaccuracies caused by human errors. The exact measure of volume is not dependent only on level; mass, temperature, and density variations have also to be taken into consideration.
Activated Sludge Plant Controller Benefits Wastewater Treatment Plants
Sensors in the wastewater treatment industry rapidly lose their effectiveness due to fouling and calibration drift. The Strathkelvin Instruments’ (UK) ASP-CON has been designed to be fully self-cleaning and self-calibrating. The image shows how, after several weeks in a highly challenging aeration basin, the sensor heads remain very clean. This is mainly due to the action of the instrument’s medium pressure wipers, but also the use of a slightly acidic flush followed by a basic flush, during the auto-calibration of the sensors.
The ASP-CON is a multi-sensor instrument measuring over 16 important Wastewater treatment control parameters in one unit. Parameters include Dissolved Oxygen, Ammonium, Mixed Liquor Suspended Solids, Settlement Volume Index, Turbidity, pH, Temperature, Oxygen Uptake Rate, Specific Oxygen Uptake Rate, Nitrification, Food: Mass ratios, Toxicity and Potassium.
The ASP-CON can be installed in a number of positions within the activated sludge part of the secondary treatment process, depending upon the desired control and monitoring strategy of the WWTP.
In a recent trial the ASP-CON was installed at around 70% of the treatment lane footprint where treatment loads varied over a 72 hour period. 3 separate measurements – namely DO, Ammonia and pH indicated that an alternative control strategy could be implemented under low loading conditions. It was estimated that by implementing
alternative control strategies during the period of low loading that this plant could save in excess of $40,000 per annum. The ASP-CON has also recently been given the WEX Global Innovation Award - further proof of its success.
For More Info, email: email:
For More Info, email:
29234pr@reply-direct.com
For More Info, email: email:
For More Info, email: email:
Anaerobic Digestion
Biodegradable material is digested by bacteria in a special tank. Depending on regulations, the produced biogas can be injected into the distribution grid and sent to a cogeneration unit to produce electricity and heat. During the process stages, it is necessary to measure the storage tank fill level, biogas pressure in the digester, flare status, and other parameters. Battery operated DX99 wireless units can help to monitor these values from the control room without having to run new cables.
9
Banner Engineering - Wireless Radio Module
Installation costs for this type of application can be very high because of the tank’s remote location, which can be several hundred meters apart, as well as being in an ATEX zone. Banner Engineering’s wireless modules connected to the instrumentation will transmit the sensor signals back to the primary control location.
Slurry Pipeline Leak Monitoring
Coal slurry is the dirty water used to wash coal during mining. After the washing process is complete, the slurry is pumped to a slurry retention pond.
To prevent the slurry from entering streams and local water supplies, retention ponds are usually created within valleys between hills. While the slurry is pumped from the mine site over hills into the retention pond, the flow rates are measured at the origination site and at the retention pond. Sensors are also positioned at pipeline splices to detect leaks.
Wireless devices and flow sensors were mounted at each end of the pipeline to detect changes in the flow rates. Wireless devices and optical sensors were used at all pipeline splices to detect the presence of liquid. When a leak is detected, signals sent from the radios back to the control location shut down the slurry pumps to minimise the leaks.
Because the total length of the pipeline can be several miles, a wireless solution eliminates the need to run power and data cables the entire length of the pipeline. The wireless devices and their sensors can also be moved if the configuration of the pipeline ever changes.
2063ad@reply-direct.com
www.envirotech-online.com IET March / April 2014
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76