Watlow: Accurate Thermocouple Wire


St. Louis, MO — Watlow, a thermal systems specialist, offers “N” Type thermocouple wire, which provides superior repeatability and resistance to oxidation than “K” Type wire at high temperatures of 1500°F and above (815°C) or in applications where sulfur is present. Watlow’s Type N thermocouple


wire meets special limits of error from 200 to 2000°F (93 to 1093°C). This nickel-based thermocouple alloy is used in many high temperature heat treating applications, including specialty aerospace heat treating. It offers the same accuracy and temper- ature limits as Type K, but has improved repeatability between 700 and 1100°F (370 and 593°C). According to the company, mul-


tiple tests have shown that Type N thermocouple wire offers improved performance and increased thermo- electric stability due to decreased effects of oxidation at higher temper- atures. In addition to industry findings,


the company recently tested Type N alloy in its ISO 17025 certified cali- bration lab to verify the special limits


Thermocouple wire. Type N wire is twice as accurate at


special limits from 400 to 2000°F. Contact: Watlow, 12001


Lackland Rd., St. Louis, MO 63146 % 314-878-4600 fax: 314-878-6814


E-Mail: info@watlow.com Web: www.watlow.com


Screwless PI-Spring Terminal Blocks From ABB


We can provide what you need.


New Berlin, WI — The new screwless SNK Series PI-Spring Terminal Block from ABB Low Voltage Products division uses a patented spring design that enables the installer to lock a screwdriver onto a terminal connected to unprepared flexible conductors. This innovation frees the installer’s hands to manipu- late wires and hold circuit drawings. SNK Series PI-Spring Terminal


Blocks combine push-in and spring technologies for efficient connections to solid and stranded wires, either with or without ferrules. According to the company, the


Printed Circuit Boards The Right Time


The Right Price 


www.divsys.com international, llc


PH: 317-405-9427 


new PI-Spring enhances its existing SNK series screw- clamp range and applies the best of 50 years of experience to one easy-to-connect, high- quality product, with common accessories. These terminal blocks are designed for medi- um and heavy industrial applications, including mar - ine and hazardous locations, as well as solar power and commercial building applica- tions. The SNK Series PI- Spring Terminal Blocks have self- guiding wire entries that enable direct, one-step, push-in insertions with solid wires and stranded wires with ferrules that are 50 percent faster than terminal blocks with screw clamps. PI-Spring Terminal Blocks also enable stranded wire to be inserted with a screwdriver to open the spring clamp. Reducing con- nection time for push-in mode and eliminating the need to prepare stranded wires for spring mode make installation quick and easy for both methods. Another advantage is the reduc-


tion of inventory by up to 50 percent, as the product eliminates the need to stock a separate line for solid and fer- ruled stranded wires, and another


separate line for unprepared strand- ed wires. In addition, SNK Series PI- Spring and Screw terminal blocks share the same jumpers, markers and accessories, while all end section and circuit separators fit multiple types and sizes of blocks. The wire entry angle of the SNK


Series PI-Spring Terminal Blocks is designed to minimize the height of the wires, while maintaining a gen- erous bend radius, which increases the integrity of the connection and decreases the space that the wires occupy for a narrower wireway in the enclosure.


of error are met, and the calibration results show that the company’s


Time-saving terminal blocks. The asymmetrical design of the


SNK Series PI-Spring Terminal Blocks provides an immediate visual check to ensure against terminal block reversal, which reduces the chance of mounting and wiring errors. Circuit identification is also improved with a 20-percent enlarge- ment of the marking area. The 30° angle of the wire entry on the termi- nal block’s profile provides up to a 15 percent increase in rail and cabinet space, while allowing a generous bend radius. The flat marking sur- face enables pre-marking by hand


before final marker installation. Contact: ABB, Inc. 1250 Brown


Road, Auburn Hills, MI 48326 % 248-391-9000


Web: www.abb.com/robotics


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80