ATEX Certified Linear Position Transducers


Pennsauken, NJ — When specifying sensors, engineering contractors, system manufacturers and even end- users must not only ensure sensor operating specifications meet appli- cation requirements, but also vali- date if components address regulato- ry and safety requirements for the country or geographic region in which they will be installed or used. Sensors certified domestically


HIGH VOLTAGE ADJUSTABLE OUTPUT MODULES DC-DC Converter • 100-1500 VDC Output


New SAR Series!


High Voltage Isolated 100 to 1500 VDC Output Adjustable, Down To 0 VDC Output Output Power 3 Watts


Minature Design: 1.1” x 0.8” x 0.4” ht. 12 grams Typical Weight Surface Mount & Thru Hole Models Available Output Center Tap for Dual Output Use See PICO’s full line catalog at


DC-DC CONVERTERS www.picoelectronics.com 143 Sparks Ave., Pelham, New York 10803 


Call Toll Free 800-431-1064 • FAX 914-738-8225 E Mail: info@picoelectronics.com


8/7/14 11:52 AM Page 1


From Pluggable to High Power Terminal Blocks


ZST Pluggable Tension Spring Connection System


are not necessarily acceptable for use overseas, especially in haz- ardous areas such as those found in oil and gas applications, nu- clear power plants, subsea as well as mining. In many coun- tries, sensors must comply with specific national requirements to ensure safety and prevent acci- dents or disasters. ATEX certification is issued


gies offer ATEX-approved LVDT Lin- ear Position Sensors and Pressure Sensors that are manufactured and certified to operate under explosive and hazardous conditions. When selecting a specific LVDT


linear position transducer or pres- sure sensor, sensor users must be fully aware of the intended environ- ment and location of its application. Look for the certification symbol, as


only after a sensor is tested to the relevant standards applicable for each type of explosion protection ap- plied to the equipment, such as flameproof, dust proof or intrinsical- ly safe devices. ATEX certification is typically the responsibility of the sensor manufacturer that uses a no- tified body for ATEX certification. Macro Sensors and its sister company American Sensor Technolo-


Certified linear position transducer.


shown above, on units or, if in doubt, ask the sensor manufacturer for clar- ification if the component is ATEX


certified. Contact: Macro Sensors, 7300


US Route 130, North Building 22, Pennsauken, NJ 08110-1541 % 856- 662-8000 fax: 856-317-1005 E-mail: positionsensors@macrosensors.com Web: www.macrosensors.com


Passive Plus Now Lot Codes All Leaded Caps


Huntington, NY — Passive Plus, Inc., (PPI) in another industry first, now provides as standard, lot code marking on all leaded capacitors. Lot traceability is easily lost during the manufacturing process; there- fore lot code marking of individual leaded capacitors will facilitate fail- ure analysis and corrective actions when necessary. In addition, the company pro-


vides lot code information for every line item on its shipping paperwork. With over 30 years in the RF/Microwave industry, Passive


Plus, Inc. manufactures high quality, high power passive components using state-of-the-art manufacturing tech- niques. Specializing in magnetic and non-magnetic hi-Q capacitor product lines, PPI supplies reliable quality components to the aerospace, telecommunications, medical semi-


conductor, and military industries. Contact: Passive Plus, Inc., 45


Whitson Rd., Huntington Station, NY 11746 % 631-425-0938 fax: 631-425-0847 E-mail: sales@passiveplus.com Web: www.passiveplus.com


HSKG High Power Stud Terminals


...and Everything In Between


Conta-Clip, Inc. offers a comprehensive line of high quality terminal blocks for applications ranging from cable harnesses to energy transmitting applications


Available Wire Connection Types: • Screw Connection System • Pressure Spring Connection System • Tension Spring Connection System • Stud Connection System • Spade Connection System


Wire Range: • 0.5 mm2


to 300 mm2


For more ZST and HSKG product line information


Ratings: • 300V up to 1000V • 15A up to 520A


Approvals: • UL


• CSA • IEC


• CE • GOST


• NEMKO • GL • KEMA


Call 732-564-0705,


e-mail: info@contaclipinc.com, or visit contaclipinc.com


usa.contaclipinc.com/ustech


NITROGEN FOR SOLDERING: BETTER.


SOLDERING: SIMPLY THE BEST.


Improve quality and lower costs with a nitrogen generator.


• Cost-saving alternative to conventional delivered nitrogen


• Ease of operation • No tanks or cylinders to switch out • 24/7 operation with same unit • Purities up to 99.9995%


CALL 888.748.3429 FOR A FREE CONSULTATION OR VISIT US ONLINE AT WWW.ONSITEGAS.COM


35 Budney Rd. | Newington, CT 06111 NITROGEN FOR


Gas Systems


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80