Water / Wastewater 17 Copper Analyser System Monitors Electronics Manufacturing Wastewater Treatment


Process and plant engineers responsible for treating wastewater from printed circuit board manufacturing, electronic components production and electronics plating operations will find the new Copper Analyser System from Electro-Chemical Devices (ECD) (USA) provides a highly accurate turn-key analyser solution for electronics manufacturing wastewater treatment processes.


The next-generation Copper Analyser System from ECD is designed with the new advanced T80 Universal Transmitter and precision S80 Intelligent pION Sensor. Together, they provide highly accurate and reliable measurement of Copper for electronics industry manufacturing plant wastewater treatment.


Copper contamination of water sources from electronics manufacturing washing and rinsing operations is a serious concern. While copper is naturally in the soil, it poses major health risks when it enters the drinking water supply and is regulated by the U.S. Environmental Protection Agency (EPA). The amount of copper that can be discharged by electronics manufacturers into public wastewater treatment systems is strictly regulated and must be monitored to ensure any effluent leaving the plant is safe.


ECD’s S80 pION Sensor for Copper combined with the T80 Transmitter is well suited for monitoring industrial wastewater treatment operations. ECD’s S80 pION Sensor for Copper uses a cupric ion electrode cartridge that measures the activity of “free” Copper ions in solution in concentrations from 1.0 ppb to 6,300 ppm.


The S80 pION sensor operates over a wide temperature range of 0 to 80º C. The S80 Immersion or Insertion Sensor is designed with a 0.75-inch MNPT compression fitting as the process connection and allows a variable insertion length to accommodate installation in pipe tees, flow cells or through tank walls. The S80 Retractable Sensor is designed with a 1-inch MNPT ball valve, a 1-x-0.75 inch reducer and a 0.75 inch MNPT compression fitting to provide the process connection.


In addition to Copper measurement, ECD’s replaceable electrode cartridges for the S80 pION Sensor can also be selected to measure parameters including other specific ions, pH, ORP and dissolved oxygen. These cartridges provide specific industrial process measurement solutions, and they are constructed in a variety of configurations and materials to support diverse industries.


For More Info, email: email:


For More Info, email: email:


30659pr@reply-direct.com


Water and Wastewater Information Group offer Range of


Networking Activites and Workshops


Multi Parameter Logger Solution CTD (Conductivity, Temperature, Depth)


• Accuracy / Range of Conductivity Sensor: ± 1% max. / 0...200 mS/cm


• Accuracy / Range of Temperature Sensor PT1000: 0,1 °C / -10…40 °C


• Accuracy / Pressure Range of Depth: ± 0,02 %FS max. / 5…200 m


• Applications: Monitoring of Water Quality and Level


The Sensors for Water Interest Group (SWIG) (UK) is a not for profit information, ideas- exchange, and networking group with a diverse UK-wide membership. SWIG focuses on the use of sensor and associated technologies for measurement and control in water and wastewater treatment processes and infrastructure, as well as in natural environments and waters.


Our networking activities include a varied programme of technical workshops covering all aspects of water sensing, which offer a cost- effective means of keeping up-to-date with sensor developments, new technologies and regulations, whilst fostering collaboration between parties. Invited speakers and enthusiastic audiences are able to debate the practical applications and current challenges for measurement and control in water and wastewater.


SWIG is pleased to be supporting WWEM on the 5-6 November at Telford, where we will be displaying the shortlisted posters from our 2014 Early Career Researcher scientific poster competition and announcing the winner during the gala dinner.


Please see www.swig.org.uk for details of our upcoming workshops (open to members and non-members), and for details of membership.


Autumn events include: 24 September: Monitoring Organics, Glasgow; 15 October: Telemetry & Remote SCADA Systems for Smarter Operational Management of Water Supply Networks, London; and 26 November: Instrumentation for TOTEX efficiencies, near Coventry.


For More Info, email: email:


For More Info, email: email:


30997pr@reply-direct.com


For More Info, email: email:


For More Info, email: email:


KELLER Your Pressure Sensing Specialist 3136ad@reply-direct.com www.envirotech-online.com IET Annual Buyers’ Guide 2014/15 www.keller-druck.com


Excellence in Hydrology


Level and Temperature Logger Solutions


• Autonomous • Easy to use • Battery-powered


• Applications: · Fresh Water · Salt Water · Dirt Water


• Available in stainless steel, hastelloy or titanium


GSM Remote Data Transmission Solutions


• Multi parameter logger


• Data transmission via e-mail, ftp or sms


• Multi functional • Battery life 10 years • Easy to install • Free software


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108  |  Page 109  |  Page 110  |  Page 111  |  Page 112  |  Page 113  |  Page 114  |  Page 115  |  Page 116  |  Page 117  |  Page 118  |  Page 119  |  Page 120  |  Page 121  |  Page 122  |  Page 123  |  Page 124  |  Page 125  |  Page 126  |  Page 127  |  Page 128  |  Page 129  |  Page 130  |  Page 131  |  Page 132  |  Page 133  |  Page 134  |  Page 135  |  Page 136  |  Page 137  |  Page 138  |  Page 139  |  Page 140  |  Page 141  |  Page 142  |  Page 143  |  Page 144  |  Page 145  |  Page 146  |  Page 147  |  Page 148