F-DGSi Lab Hydrogen Generator's Expanded Capabilities The F-DGSi H2 generator saves space and eliminates the risks associated


with storing high pressure cylinders, but also the hidden costs associated with piping connections, manometers, ordering, renting, delivering, servicing and maintaining cylinders.


The F-DGSi Hydrogen generators use the latest polymer electrolyte membrane (PEM) technology to produce high purity hydrogen. The exclusive ‘No Maintenance’ gas column dryer regeneration system eliminates all down time for maintenance that is typical of other systems on the market, guaranteeing the best hydrogen purity at all times.


The exclusive cascading option allows up to 10 units to be connected in series, producing flowrates up to 12 litres! This feature gives the capacity to supply H2 simultaneously to multiple GC and GCMS units.


The system's internal self-diagnostic features, high visibility lighted display, internal/external leak detection and all the remote control and alarm capabilities increase lab safety and productivity.


The exclusive safety on the market to use H2 as carrier gas: don’t be afraid anymore to use H2 gas as carrier gas: thanks to our H2 sensor controlled by our H2 generator: in case of any leak inside the oven of the GC, the H2 generator will stop to produce.


The modular generator design allows it to be used individually or coupled to any one of the Zero air generators to form an all-in-one FID Gas Station solution for GC combustion detector applications.


The exclusive high pressure: the Hydrogen generator is able to give an outlet pressure up to 16 bar as an option.


This unique feature opens a wide range of new applications like: the operation of fuel cell, as well the filling of low pressure metal hydride canisters for operating portable GC or mobile systems.


F-DGS i offers 4 x ranges of laboratory hydrogen gas generators LC-H2 99.995%, ND-H2 99.9995%, PAR-H2 99.9999%, WM-H2 99.99999%.


With flow rates from 120 cc/min to 1200 cc/min depending on the models.


Circle no. 34


N2 Generators for LCMS, GC and General Applications


F-DGSi has taken huge steps to improve the functionality of its N2 generators. We have re- designed its core range of N2 gas generators and implement a serie of unique features and end user


benefits, making our N2 range, the most complete one and the best in the market.


Our Nitrogen gas generators are quieter, more efficient, technically advanced in terms of safeguards and offer the user more functionality in control than anything else on the market. To compliment our generators we also provide complete filtration and purification solutions for the feed air supply, together with post-treatment and gas storage systems.


For LCMS applications we can also offer both PSA and Membrane technology depending on the application and end user preference. The flow rate range allows single or multiple instruments to be supplied.


Our PSA NG series LCMS exists with different flow rates (12 L/Min to 40 L/min), with or without integrated compressor.


Our NG6/1 DF model provides dual flow Nitrogen gas to meet the drying, sheath, nebulisation and collision gas requirements of the AGILENT triple Quad or Q-TOFinstruments.


For GC application and general application we employ PSA technology to deliver best in class life expectancy. An integrated oil-free compressor is optional, but all generators provide N2 at purities ranging from 98% to 99.9995%. Zero Nitrogen and Combine N2 /AIR generators are available for more specific GC applications.


Circle no. 35 Air Generators for GC-FID, TOC


F-DGSi proposes three models: ZERO AIR without integrated compressor: produce dry and hydrocarbon-free air < 0.05 ppm, using catalytic technology and connecting it to a dry compressed air supply. Allows it to be used individually or coupled to any one of the F-DGSi H2 generators to form an all-in-one FID gas station solution for GC-FID applications


ULTRA ZERO AIR built in compressor: it uses the combination of high level filtration through a dryer and catalytic technologies to produce a clean and dry air with hydrocarbons down to


0.05 ppm, H20 dewpoint < -50°C. The generator is controlled using the latest in HMI touch screen to display the process in real time.


TOC AIR GENERATOR built in/ without compressor: F-DGS’s TOC Air generators are some of the smallest and most efficient Hydrocarbon-free air and CO2 purifier systems for laboratory use. Utilising a heated catalyst technology which is combine with a CO2 removal air dryer to remove THC including methane to less than 0.05 ppm, CO2 less than 1 ppm and H20 dewpoint < -70°C. This TOC air station is controlled using the latest in HMI touch screen technology to display the process in real time.


Circle no. 33


Our “ALLIANCE”: A CHANCE TO work together to MAKE THINGS BETTER


“ALLIANCE”: The partnership that keeps the Gas Flowing.


Following extensive market research and technical development, we are now introducing to the market the brand new ALLIANCE range of laboratory Gas Generators.


A completely new Hydrogen, Zero Air and Nitrogen product line, the ALLIANCE range of generators incorporates the latest technologies available, in a sleek and appealing design.


Our Nitrogen gas generators are quieter, more efficient and offer the user more functionality in control than anything else on the market. We can also offer both PSA and Membrane technology depending on the application and end user preference.


With Hydrogen we offer the most extensive range of generators on the market and have incorporated many unique features bringing enhanced safety and functionality to the end user.


IQ/OQ documentation, full service support from specification to physical installation on site, as well as the on-going preventative maintenance of the entire package, provide complete peace of mind when using an F-DGSi product.


Our emphasis is on the development of turnkey solutions to provide benefits to our customers by meeting their gas supply requirements in a comfortable, safe and cost-effective manner.


F-DGSi is located near Paris (EVRY) and our offices have enough space to accommodate administrative, commercial and technical teams under one roof. Within our office we have a well equipped lab, modern show room and dedicated area for after sales service and support teams. Keeping the gas flowing is critical to our customers and to ourselves and hence we always maintain an exhaustive service inventory of both spare parts and fully functional generators, aimed at providing fast deliveries and state of the art technical and application support to our Customers. Our 400 m2 facility perfectly matching and fulfilling our Number One objective of a continuous enhancement of the services provided to the Customers as well as helping us to honour our aphorism: of always being one STEP AHEAD of the competition.


All of our laboratory gas generators offer superb technical performance and end user benefits in the lab, and, of course, our world- class service and support come as standard. We feel confident that we offer the best gas generators on the market.


To find out more, please call: +33 1 64 98 21 00, Email: info@f-dgs.com, Web: www.f-dgs.com


Circle no. 36


INTERNATIONAL LABMATE - JANUARY/FEBRUARY 2012 - ADVERTORIAL


See us at:


Pittcon: Stand 3106-3108 Arablab: Stand 150


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92