This page contains a Flash digital edition of a book.
appropriate should plant rating noise levels at residential receptors be greater than 35dB(A) (including a tonal penalty) the actual limit for plant noise would be 35dB(A). The level of 35dB(A) is therefore used within this chapter as the threshold designating a high magnitude of effect when assessing operational noise from the converter station and its effect on the noise environment of a key receptor.


Code of Practice for Noise and Vibration Control on Construction and Open Sites - Part 2: Vibration (BS 5228-2: 2009)


37.


BS5228-2 provides guidance on the control of vibration from construction sites and response limits for cosmetic damage in buildings and provides limits at which the vibration level (measured as a peak particle velocity) would result in cosmetic damage at a range of vibration frequency levels.


38.


BS 5228-2 also presents levels of vibration that may cause complaint, which is predicted to occur between 0.3 mm/s (just perceptible) and 1.0 mm/s (likely to cause complaint). BS 5228-2 values have been taken into consideration in the assessment of vibration levels from construction HGV traffic.


Prediction Methods


On-site construction noise 39.


The assessment of construction noise is predicted utilising a methodology provided by BS5228, and is based on the project description (outlined in Chapter 5 Description of the Development). The plant required for construction would be determined by the contractor selected post-consent and therefore assumed plant has been used in predictions, based on an estimation of noise levels provided by the equipment supplier.


40. Noise level data have been taken from Annex C and D of BS 5228-1: 2009. All sound pressure levels are given at a distance of 10m from the measured plant. Operational time refers to the percentage the equipment is on in an hour when it is deployed on site within working hours and an on time of 75% is assumed, based on Royal HaskoningDHV experience of this type of project.


Preliminary Environmental Information May 2014


East Anglia THREE Offshore Windfarm


Chapter 26 Noise and Vibration Page 13


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58