and fi ve magnetically activated switches, which are back lit to help confi rm the correct button is being pressed.
CONDENSING OR HUMID ATMOSPHERES ARE NO SWEAT FOR FALCO FIXED PID FROM ION SCIENCE
New online video highlights how Falco’s ground-breaking
Typhoon Technology enables reliable monitoring of VOCs in severe weather conditions
Ion Science – leading designer and manufacturer of gas detection instrumentation for global occupational health and environmental monitoring applications – highlights the suitability of its Falco series of fi xed continuous photoionisation detectors (PIDs) for monitoring a wide range of volatile organic compounds (VOCs) in condensing atmospheres and severe weather conditions using a new online video.
http://www.ionscience.com/falco-typhoon-technology
Setting a new benchmark in fi xed VOC monitoring, the advanced Falco offers a fast response to hydrocarbons, solvents, degreasers, paints and fumigants. This helps ensure plant-wide safety and the protection of workers operating in potentially hazardous environments, such as oil refi neries, paint booths, shipping fumigations, chemical waste storage areas, polymer plants and pharmaceutical laboratories.
The simple video shows how by utilising the same market-leading PID sensor and advanced patented fence electrode technology as Ion Science’s proven Tiger handheld VOC detector, Falco does not experience quenching of response due to humidity in the ambient air. This increased resistance to humidity and contamination ensures optimum reliability and accuracy in the fi eld, as well as considerably reduced drift issues and extended run time.
It also demonstrates how Falco’s ground-breaking ‘typhoon’ technology prevents condensation forming on the sensor which eliminates the risk of it short circuiting and makes the instrument particularly ideal for harsh conditions and wet outdoor environments, as well as removing the need for weather enclosures. Other potential Falco applications include monitoring the headspace of refi nery wastewater streams for excessive hydrocarbon contamination and measuring the effl uents of activated carbon systems used to treat contaminated water.
Simple to operate, Falco features an externally located Intrinsically Safe (IS) sensor for quick and easy servicing, without the need for a hot work permit, and can be serviced and calibrated in a hazardous environment without having to remove power.
There are eight models in the Falco series offering detection ranges as low as 0 - 10ppm with ppb sensitivity or as high as 0 – 3,000 ppm.
Falco is operated via an intuitive user interface with OLED display
Figure 2 shows how the Falco can be used in condensing environments. The fi rst and third Falco instruments incorporate Ion Science’s new ‘typhoon’ technology which prevents condensation on the sensor and avoids operating faults or corrosion. The second and fourth units, which do not have the new ‘typhoon’ design, show the fault condition.
Figure 2 – Falco used in condensing environments
Falco utilises a diffusive sample technique resulting in less contamination issues compared to pumped systems and reduced lamp cleaning and servicing requirements. Pumped models are available for applications where a sample needs to be drawn to the unit.
For added convenience and ease of use, brightly coloured red, amber and optional pulsing green status indicators are clearly visible in sunlight allowing checks to be conducted from a distance.
The Falco’s fl ame proof enclosure is certifi ed to EX d IIC T4 II and the external sensor to EX ib IIC T4 Gb II. A 4 – 20 mA analogue output enables Falco to be easily integrated into a DCS control system to give warning or control of high VOC levels in the working environment. Two relay outputs means it can be connected remotely plus RS485 output with Modbus protocol included as standard allows the instrument to be connected to a network.
Figure 1 illustrates how the Ion Science PIDs are unaffected by humidity whilst competitor instruments show a drop in response at high humidity. Attempts to compensate for humidity quenching using an RH sensor are inconsistent, resulting in gross overcompensation when the compensation algorithm is turned on. Ion Science PIDs are inherently insensitive to humidity, don’t require any compensation and are more accurate at high RH.
Figure 1 – effect of RH on Tiger V competing PID instrument
Sam Holson | Marketing Manager. Ion Science • Ion Science Ltd, The Way, Fowlmere, Cambs. SG8 7UJ Tel +44 (0)1763 207206 • Email:
sam.holson@ionscience.com • Web:
www.ionscience.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84