60 Anton Paar’s Rotational Viscometer: For Reliable, Traceable Results
When you switch to Anton Paar’s rotational viscometer, ViscoQC, you can continue using your current SOP (measuring procedure) – if the same setup and settings are used. ViscoQC will deliver the same results. Unique features preventing operator error ensure reliable, traceable viscosity measurements with no unplanned extra costs:
• Toolmaster™: Anton Paar’s automatic spindle recognition delivers viscosity results you can rely on – all spindle data is automatically delivered to the viscometer as soon as the spindle is attached, error free for 100% traceability. There are no time-wasting repeat measurements (e.g., if the wrong spindle is mistakenly chosen from the spindle list).
• Magnetic coupling: Each spindle is equipped with magnetic coupling for easy spindle exchange, saving you up to 15 seconds per test. The coupling also reduces maintenance costs by protecting the spindle and instrument against damage caused by knocks or bending.
• Digital levelling: Built-in digital levelling automatically indicates and monitors the correct levelling status of your configuration, which prevents faulty measurements and ensures superb, full-scale-range accuracy of ±1%. The levelling status is stored in the measurement report to maximise traceability.
More information online:
ilmt.co/PL/r14E 59596pr@reply-direct.com
Compliance: Full Audit Readiness with 70% Less Personnel Work
Assuring time- and cost-efficient compliance and traceability - crucial to delivery of safe, high-quality products - is a challenge in the tightly regulated pharmaceutical and biopharmaceutical industries.
Anton Paar’s ViscoQC 300 turnkey customised qualification package, along with qualified installation support, delivers a fully qualified analytical environment and reduces in-house personnel work by 60% to 70%. The qualification goes significantly beyond simple installation and basic IQ/OQ. It involves individual preparation for every system. A detailed risk analysis, performance qualification, traceability matrix, and final qualification report increase the value of the qualification package for the whole qualification process for the customer.
Looking for advanced data integrity and 21 CFR Part 11 compliance? With the V-Comply software, which also includes the Pharma Qualification Package, you cover all necessary requirements like audit trails, electronic signature, data security, login controls, user authentication, and many more - all of which can also be proven during qualification.
Additionally, each Anton Paar qualification package comes with a customisable SOP template as a base for the customer’s own SOP. The documents used can be fully and seamlessly integrated into the user’s own qualification process and comply with <USP 1058>, <USP 1225>, and EP Annex 4 Part 11 & PIC/S Chapter 5 & 6. Tailored requalification maintains an instrument or system’s qualification status - and thus its productivity - over the whole instrument lifetime.
Thousands of customers trust Anton Paar’s expertise. Thousands of qualified instruments have passed audits with Anton Paar qualification documents. More information online:
ilmt.co/PL/jxpv
59597pr@reply-direct.com
From Nasal Drops to Waxes: We Have You Covered
ViscoQC offers a broad portfolio of interchangeable accessories and spindles covering all types of samples – from liquids to semi-solids – to expand your measuring capabilities with minimal investment.
• PTD 100 Cone-Plate: The cone-plate measuring system with an integrated Peltier temperature device is ideally suited for limited sample volumes from 0.5 mL to 2 mL. It offers a wide, precise temperature range from 0°C to 100°C and is fully controlled via the ViscoQC display. The gap setting is fully automated, and continuous monitoring of the set gap prevents invalid measurements. No extra dedicated cone-plate viscometer is required.
• Heli-Plus: The motorised stand with the typical T-Bar spindles is perfectly suited for creams and paste-like samples (e.g., ointments, gels). Heli-Plus automatically moves the ViscoQC head up and down via digitally defined start, immersion, and reversing positions, which can be set and saved for each method individually. A standardised test procedure ensures the highest-possible repeatability.
• PTD 80 & PTD 175 Peltier temperature devices: Say goodbye to slow, noisy, space-consuming, maintenance-intensive circulator baths. PTD 80 (15°C to 80°C) and PTD 175 (-45°C to +175°C) offer accurate, fast sample temperature control. They require no extra lab space and are fully controlled via the ViscoQC screen. The unique T-ReadyTM
function signals when the sample has reached the set temperature,
eliminating extra waiting times for temperature homogenisation. Save time, space, and frequent maintenance costs. More information online:
ilmt.co/PL/o1oJ
59598pr@reply-direct.com
Highly Accurate Viscosity Results with as Little as 100 µL of Sample
Anton Paar’s Lovis rolling-ball viscometer, equipped with short capillaries, enables reliable and precise determination of dynamic viscosity for low-volume applications in, for example, the pharma, medical, and healthcare industries.
Lovis measures according to the established Höppler principle and therefore complies with methods 911 and 913 in the US Pharmacopeia as well as method 2.2.49 in the European Pharmacopeia, to ensure easy validation. Additionally, all necessary data integrity features required for compliance with 21 CFR Part 11, like audit trails, electronic signature, and user identification, are included in the integrated software. Together with the optional qualification packages containing all relevant documents, this makes qualifying your instrument easier than ever before.
Lovis capillaries are available in both borosilicate glass and PCTFE, which extends the range of applications to corrosive and toxic substances. The hermetically closed design together with the small sample volume (100 µL) increases lab and operator safety by eliminating evaporation and contamination. It also allows sample recovery for further analysis after the viscosity measurement. Built-in Peltier thermostatting allows fast and stable temperature control over a wide temperature range (5°C to 100°C stand-alone, and down to -30°C with counter-cooling) for samples in the viscosity range from 0.3 mPa.s and 10,000 mPa.s, with an accuracy of up to 0.5 % and repeatability up to 0.1%.
Even more information can be delivered in combination with other Anton Paar instruments like the DMA density meter or Abbemat refractometer. The powerful polymer software automatically calculates intrinsic viscosity, K-value, molar mass, and other crucial parameters.
Whether for research or industry, Lovis 2000 M/ME gets a lot out of just a little sample. More information online:
ilmt.co/PL/YvWp
59599pr@reply-direct.com
INTERNATIONAL LABMATE - FEBRUARY 2023 - ADVERTORIAL
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80