search.noResults

search.searching

saml.title
dataCollection.invalidEmail
note.createNoteMessage

search.noResults

search.searching

orderForm.title

orderForm.productCode
orderForm.description
orderForm.quantity
orderForm.itemPrice
orderForm.price
orderForm.totalPrice
orderForm.deliveryDetails.billingAddress
orderForm.deliveryDetails.deliveryAddress
orderForm.noItems
New Nexera Prep: Better Prep


Shimadzu, one of the world leaders in analytical instrumentation, has announced the release of its new Nexera Prep Series Preparative Purification Liquid Chromatograph (LC). ‘Preparative HPLC’ is a process in which specific substances are separated and purified from samples. The new Nexera Prep Series provides better prep processes for extraction of functional and impurity components, as well as purification of target compounds in the pharmaceutical, chemical and food industries. This product dramatically improves productivity via flexible scalability and an efficient, user friendly preparative workflow.


Customer- and application-specific solution


The Nexera Prep Series consists of multiple related products with the LC units as the core. Users select a pump, autosampler and detector to build a system according to the purpose of the preparative work. Systems can be configured using related products such as the LH-40 Liquid Handler, FRC-40 Fraction Collector, Shim-pack Scepter LC Column for Analysis and Preparative Work, and Column Hub.


Preparative purification is generally performed following a multi-step workflow, which requires experience and time: • Selection of system configuration and preparative column size based on the amount of purified sample or injection volume required • Selection of fraction collector and container size according to the intended purpose • Investigation of separation conditions in analytical scale • Optimisation of preparative LC conditions • Confirmation of the purity of collected fractions


In addition to these steps, in some cases salts need to be removed or solvent needs to be evaporated after purification, requiring additional time and effort.


Time-saving by simplified, fast operation The Nexera Prep Series reduces the time spent on examining conditions using the software’s fractionation simulation function. It also enables simplified, fast operation in transition from analytical to preparative scale, with a column portfolio that covers a wide range of sizes. Furthermore, Shimadzu’s unique UFPLC (Ultra Fast Preparative and Purification LC) high-purity purification system reduces the time required for powderisation via the elution of desalted target components with an organic solvent. This product satisfies a number of user demands, such as efficient desalting and powderisation, multi-sample and multi- fraction analysis, effective separation at low cost and the ability to check the purity.


Specifically, the product can be used for the following purposes:


• Concentration and purification of immunosuppressive agents


• Preparative work for impurities in degradants of medicinal agents


• Separation and purification of functional components from natural materials


• Consecutive analysis to separate and purify polymers and their additives and confirm the purity


The Nexera Prep Purification LC System provides new features to simplify the preparative workflow:


Reduces the time required for investigating conditions


With the fractionation simulation function of the LabSolutions analysis software and the Shim-pack Scepter LC column for analytical and preparative HPLC, which offers excellent scalability, the product reduces the time required for investigating preparative work conditions. The LH-40 Liquid Handler can be used both, as a fraction collector and as an autosampler for large-volume injection with liquid surface detection function (option). It also enables seamless purity checks through re-injection (option) of collected sample after fractionation. Additional features including a sample rescue protocol to collect the sample from the system if an error occurs after an injection, a function to automatically extract the target peaks only, and high-purity preparative purification using detector signals from up to four channels,


enable more efficient operation. Better Prep! Keep it simple, stay flexible


The Nexera Prep Series Preparative Purification LC improves productivity tremendously via efficient preparative work using application-specific LC or LC-MS solutions. It provides better prep processes for drug discovery and purification of functional components in pharmaceutical, chemical and food industries.


Ease-of-operation in a flexible set-up supported by flexible choice of detectors and efficient process automation


Simplifies the fractionation programming using the LabSolutions software’s fractionation simulation function


Preparative LC System


High sample capacity with a reduced footprint through a space-saving design with support of custom racks


Fast recovery of highly purified target compounds by automation of fractionation, concentration, purification and recovery


UFPLC high-purity purification system Samples must be in a state of concentrated solution or dry powder to analyse their structure or to store them. When a solution contains water, it takes time to dry and concentrate it. When a salt such as trifluoroacetate has been added, it remains in the crystal of the compound, lowering the purity and negatively influencing pharmacokinetic studies and other tests. Shimadzu’s unique, automated UFPLC purification system introduces fractions containing the target compound, separated in a preparative column, into a trap column. Salt and water are then washed off and elution is induced with an organic solvent. This reduces the time required for drying, providing compounds with a


high level of purity. Flexible system scalability


Both the LH-40 Liquid Handler and FRC-40 Fraction Collector are designed to save installation space, requiring only half the space of other vendors’ products. They support containers of a form and size suitable for the recovered quantity. Up to six units can be connected, so up to 3240 10 mm diameter test tubes can be placed. Using the new Column Hub, up to six columns and four flow-line switching valves can be installed, enabling the compact configuration of


various systems. www.shimadzu.eu/better-prep SHIMAEU_2023_010_AZ_NexeraPrepLC_180x254_RZ.indd 1 18.01.23 10:42


More information online: ilmt.co/PL/LaDP 59626pr@reply-direct.com

Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80