BENZENE – MEASUREMENT OF PPB LEVELS ACCURATELY IN REAL TIME
The DV3000 gas analyser from Duvas Technologies can detect 15 compounds simultaneously to low ppb levels in fi xed or transportable applications. Benzene can be directly measured instantly with no cross sensitivity issues.
Exposure to benzene has been shown to cause bone marrow damage which can lead to acute myeloid leukaemia (AML)1
. . There
is also evidence that exposure to benzene can cause damage to the reproductive organs1
Many techniques have been used to measure total hydrocarbon levels, measurement of benzene against a background of other BTEX gases is much more diffi cult. This diffi culty in measurement has meant there has been a reluctance to reduce allowable levels of benzene in the atmosphere. The current long and short term exposure levels can be seen as a direct result of the lack of simple to use techniques capable of accurately measuring lower concentration levels.
The World Health Organisation have stated that “Benzene is carcinogenic to humans and no safe level of exposure can be recommended”2
.
Current techniques for measurement of benzene in air include GCMS and diffusion tubes. GCMS is complex and expensive whilst diffusion tubes offer low accuracy, “one off” sample measurement. The combination of diffusion tubes as a “preselector” together with a PID (photon ionisation detector) can be used for selective benzene measurement but only at relatively high concentrations and not for real time continuous readings.
Duvas has developed the DV3000 instrument which uses DOAS (differential optical absorption spectroscopy) to measure benzene at low ppb levels in real time. Selectivity of detection against a background of other BTEX gases is extremely good. The DV3000 produces real time readings (20ms readings) which averaged over a few seconds can offer detection levels of better than 5ppb.
The DV3000 was evaluated by the EPA (Environmental Protection
Agency) during development and is now being used by the EPA in the USA for fi eld detection of benzene and other fugitive emissions from industrial plants. The instrument is proving reliable and simple to use. The DV3000 is used in transportable mode in the back of an SUV to provide area coverage together with pollution mapping.
The EPA are at the forefront in developing legislation to enforce better control on benzene exposure in the environment. In September 2015, Legislation drafted by EPA on requirements to monitor fugitive fenceline emissions from the 147 US petrochemical refi neries was signed into the stature books 3
spillage of petrol. This requirement will see the involvement of OSHA who will defi ne the legislation and management of this hazard. This development will require low cost personal monitoring equipment which will challenge manufacturers to meet price and performance targets which will be challenging.
. This
legislation requires refi neries to implement fenceline monitoring procedures within a three-year period. Evaluations of acceptable monitoring methodologies are being evaluated and include DOAS.
The EPA visualise this kind of fenceline legislation being applied to other chemical manufacturing plants as well as storage and distribution of materials capable of causing atmospheric benzene pollution. Enactment of such legislation will greatly increase the requirement for effective measurement instrumentation, possibly in simpler, lower cost versions.
Duvas recognises that the increasing concerns on benzene toxicity will require a range of solutions and is already working to meet anticipated requirements from other industries and from the anticipated hazards which will be present in the distribution and storage of benzene.
As ongoing concerns over benzene toxicity translate into tighter regulatory control, the retailing of petrol through fi lling stations will require monitoring techniques to ensure staff and public are not exposed to high levels of benzene from the handling and
Duvas is positioned to supply instrumentation to all levels of the supply chain. The current DV3000 represents proven capability of reliably detecting low ppb levels of benzene at the fenceline. Variants of the standard instrument can be supplied with sampling capability to sample automatically at 20 metre intervals along the fenceline of a refi nery giving both complete fenceline and specifi c leak location information.
Duvas is developing a smaller, lower cost, instrument which can be deployed for point detection in smaller facilities. The company is also developing a personal monitor to protect individual staff in transport, distribution and retail situations.
To discuss how Duvas might help you combat this serious toxicity hazard, talk to Duvas Technologies today.
References:
1. Agency for Toxic Substances & disease Registry: Toxic Substances Portal – Benzene, August 2007, cas# 71-43-2
2. World Health Organisation: Exposure to Benzene: A Major Public Health Concern, 2010
3.
http://yosemite.epa.gov/opa/admpress.nsf/0/ D12EDC1C383ADF0385257ECF005B96B6
Author Contact Details Dr David Frew, CEO, Duvas Technologies Ltd • Email:
d.frew@
duvastechnologies.com • Web:
www.duvastechnologies.com
IET Annual Buyers’ Guide 2016/17
www.envirotech-online.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108 |
Page 109 |
Page 110 |
Page 111 |
Page 112 |
Page 113 |
Page 114 |
Page 115 |
Page 116 |
Page 117 |
Page 118 |
Page 119 |
Page 120 |
Page 121 |
Page 122 |
Page 123 |
Page 124 |
Page 125 |
Page 126 |
Page 127 |
Page 128 |
Page 129 |
Page 130 |
Page 131 |
Page 132 |
Page 133 |
Page 134 |
Page 135 |
Page 136