Air Monitoring 19 New Optical Fine Dust Sensor


The fine dust sensor FDS 15, from Dr. Födisch Umweltmesstechnik AG (Germany), is an optical sensor for continuous measurement and control of fine dust contents. It can be integrated into several applications. By means of the FDS 15 it is possible to determine the current fine dust loading of the environment and make out health hazards.


Application examples include: monitoring of fine dust in the range of production (workshops, factory buildings etc.), monitoring of room air quality in offices and public institutions (hospitals, schools etc.) or in the private domain, monitoring of ambient air, and upgrading of weather stations.


The determination of the dust content in the FDS 15 is based on the method of scattered light measurement. The sucked air is pre-heated to 50 °C. Thereby flow enforcement takes place via the integrated fan. The velocity of the measuring gas is chosen in a way that ensures particles are determined representatively. For the analysis of alveolar particle fractions (PM2,5) an integrated pre-sep arator is used.


In the FDS 15 a periodic control and correction of zero point and reference point is carried out. By evaluation of the internal measuring signals a high zero point stability is achieved. 39706pr@reply-direct.com


Determination of TOC in Stacks with an Innovative and Easy to Carry FID Analyser


PROBLEM: The Volatile Organic Compound (VOC) emissions of industrial chimney’s are becoming issues of global importance, and having accurate knowledge about how to test VOC turns into a strategic issue. VOC emissions are quantified and monitored according to the standard EN 12619, using an FID analyser which uses hydrogen and other reference gases in pressurised cylinder. Operators must then approach the sampling point, often placed several meters from the ground, climbing chimneys of industrial settlements with instruments and cylinders.


Is it possible to make this job easier and safer?


SOLUTION: Using the Polaris FID analyser from Pollution Srl (Italy), it is possible to carry out VOC monitoring according to EN 12619 without lifting the accessories and heavy weights typically involved with an FID analyser.


So far, the portability of such an analyser was a feature of FID’s designed for fugitive emission monitoring from valves, flanges, gaskets, pumps or compressors monitoring. Moreover, when VOCs are measured in chimneys according to EN 12619, the analyser must be much more robust and fully heated to 180°C, leading to an increase in size and weight.


Polaris FID analyser complies with this standard regulation, but what is really a breakthrough, and cutting-edge, is the unmatched portability and the next generation technology.


In addition, the Polaris FID is a new concept and incorporates into chassis these important features: two rechargeable batteries that last more than three hours; a zero air cylinder for 10 hours of continuous measurement; a span gas cylinder useful for tens calibrations and, last but not least, an advanced metal hydrides cartridge for hydrogen storage to fuel the flame detector. However, the hydrogen source is not the ordinary pressurised cylinder but a small steel cartridge that weighs only 500 grams and which allows to store hydrogen for 30 hours of continuous measurements. Furthermore, as hydrogen is chemically bonded to a special metal alloy inside the cartridge, there is no risk of leakage and explosion: hydrogen cylinder will not be a concern anymore.


In conclusion, the Polaris FID incorporates, in just 13 kg and a compact body, everything needed for a measuring campaign, making it the best choice for operators who have to climb on the chimneys of industrial settlements easily and safely.


Mobile Hot Gas Analysis without Instrument Air Provision


For More Info, email: email:


For More Info, email: email:


The mobile multi component analyser MCA 14 m, from Dr. Födisch Umweltmesstechnik AG (Germany), is an extractive, continuous measuring system. It serves the continuous emission measurement of pollutants in flue gas (e.g. CO, NO, N2 CH4 O2


, HCl, SO2 ) and the measurement of CO2 as well as the continuous process control.


The mobile MCA 14 m is applicable all-purpose for measurement of emissions, raw gases or processes. In operational emission measurement systems, amongst others, it serves the exhaust concen tration control in combustion plants with different types of fuel, the thermal waste treatment, the combustion optimisation and the process management control. Using the MCA 14 m, up to twelve infrared gas components can be detected simultaneously. All con centrations requiring specifications are evaluated internally. Thereby, the photometer control, sensor evaluation and interface communication, amongst others, are realised.


The unique characteristic of devices of this power class is that for operation of the MCA 14 m there is no instrument air supply necessary. The zero point setting is carried out with ambient air.


For More Info, email: email:


For More Info, email: 39704pr@reply-direct.com Visit www.geotechuk.com or call +44(0)1926 338111


For More Info, email: email:


5551ad@reply-direct.com www.envirotech-online.com IET Annual Buyers’ Guide 2016/17


O, NO2 , H2


, NH3 , O and 38043pr@reply-direct.com


THE EASIEST WAY TO MEASURE TOC IN STACK EMISSIONS!


TOP-LEVEL FID ANALYSER:


Metal Hydride Hydrogen Storage: Lightweight, Safe Enclosed Span Gas & Zero Air:


Rechargeable Batteries Operation: Compact & Ergonomic


Person-portable


USB Port to Upload Parameters and Download Data: EN12619 TUV Certified:


Regulations Compliant Modern & Effective


FOR MORE INFORMATION CONTACT US:


For More Info, email: email:


BIOGAS 5000 - ATEX certified portable gas analyser


- Collects consistent data for improved analysis and accurate reporting


- Helps to check your digester process is running efficiently


For More Info, email: email:


Analysis at your Site


POLLUTION SRL Via Guizzardi, 52 - 40054 Budrio - BO - Italy Tel: +39 051 693 1840 - Fax: +39 051 693 1818


6655ad@reply-direct.com


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108  |  Page 109  |  Page 110  |  Page 111  |  Page 112  |  Page 113  |  Page 114  |  Page 115  |  Page 116  |  Page 117  |  Page 118  |  Page 119  |  Page 120  |  Page 121  |  Page 122  |  Page 123  |  Page 124  |  Page 125  |  Page 126  |  Page 127  |  Page 128  |  Page 129  |  Page 130  |  Page 131  |  Page 132  |  Page 133  |  Page 134  |  Page 135  |  Page 136