Water / Wastewater 33
Reasonable, Entry- Level Model for Professional Acoustic Water Leak Detection
Just in time for the opening of IFAT, Hermann Sewerin GmbH (Germany) launched a new system for professional electro-acoustic leak detection: the AQUAPHON A 50. The small, lightweight and compact A 50
receiver has everything you need to electro- acoustically locate leaks in water pipe networks. This new product, introduced for the first time at the trade fair, is the reasonable, entry-level model for professional acoustic water leak detection. It completes the portfolio of devices previously developed by Sewerin in the water product segment.
The A 50 receiver, in striking Sewerin orange, is part of the AQUAPHON family, the internationally known, tried and true system for electro-acoustic water leak detection. The receiver, along with the other components, easily and reliably prelocates and pinpoints leaks in the water pipe network. In combination with Sewerin headphones and the UM 50 universal microphone or TS 50 test rod, the receiver provides extremely high-quality reproduction of noises typical of leaks. The IP65 protection class receiver features a robust plastic housing and can be used both indoors and out. In addition to the acoustic reproduction, the display also helps by visualising the noises, enabling users to carry out clear, differentiated evaluations. The noise intensity is displayed including the current noise level and previous minimum noise levels – it is displayed clearly in easy to read numerical values as well as graphically using a bar. The activation key conveniently starts and stops measurements and you can switch between hold and toggle mode. Adjustable filters make it possible to customise the frequency ranges to your hearing. Lower and upper filter limits can be changed (six levels each); a notch filter can be set. Further, adjustable volume and hearing protection ensure a comfortable, safe working environment. In the SDR product version (Sewerin Digital Radio) the A 50 receiver allows for the use of the F8 wireless headphones: more freedom of movement, fewer annoying cables. It is also possible to connect a second set of K3 wired headphones so that two people can hear the noises at the same time. This is useful, for example, for training/educational purposes.
Sewerin product developers paid special attention to user friendliness and carrying comfort when designing the system: The A 50 receiver boasts an illuminated display featuring optimised tilt angle – depending on how it is carried the display automatically rotates by 180°, making it perfectly easy to read at any time. There’s more: at a mere 400 g the receiver is extremely lightweight, compact and manageable, allowing you to carry it comfortably and effortlessly attached to a belt clip or using a carrying strap. It is always easy to access and ready for use - the high-quality lithium ion battery provides great power reserves, even without recharging.
The entire AQUAPHON A 50 system scores points with long availability, the operating time is more than 30 hours. Enough power for an entire work week.
For More Info, email: email:
For More Info, email:
39521pr@reply-direct.com
For More Info, email: email:
For More Info, email:
Measure up to 4 Parameters Simultaneously with New Digital Transmitter
The new digital transmitter ACTEON 5000 was designed to provide the possibility of combining the connection of digital sensors of AQUALABO (France) CONTROLE – PONSEL MESURE range for monitoring parameters pH, annular ORP, temperature, dissolved oxygen ( optically ), conductivity, salinity, turbidity (NTU , mg/L), MES (g/L), sludge blanket (%) ... . as well as analogue sensors (0-10 V, 4-20 mA) type level measurement .
The transmitter offers: 2 digital sensors inputs, 2 analogic inputs (0-10 V/ 0-20 mA power supply 12 V), 2 relay inputs, 2 analogic outputs (0/4 -20 mA), and 2 relay outputs (NO/NF).
The data measured by the sensors connected to the transmitter are registered in the ACTEON 5000 and exported in csv format (via USB key). The ACTEON 5000 is associated with a wide range of digital sensors resistant to disturbance: preamplifier integrated sensor and digital signal processing All calibration data regarding the history, users and measures are handled directly in the sensor for traceability and extreme reliability measures.
Owing to over 60 years of experience in the conception of physicochemica measurement sensors, digital sensors of the DIGISENS range are robust and specially designed for field applications continuous measurement.
Applications include: Control of aeration tank in wastewater plant, drinking water (control raw water), fish farm tanks monitoring, and industrial waste water treament
For More Info, email: email:
For More Info, email: email:
39748pr@reply-direct.com
Temperature, Level and Conductivity Meter
The Model 107 TLC Meter provides accurate, stable temperature and conductivity measurements, displayed on a convenient LCD display for easy reading. Static water level and depth of readings are read off Solinst (Canada) PVDF flat tape, which is precisely laser- marked every millimeter or 1/100 ft. Tape lengths are available up to 300 m (1000 ft).
The 19 mm (3/4”) diameter probe measures conductivity that has been standardised
to 25 degrees Celsius (Specific Conductance). Calibration is simple, with a single, or up to four-point calibration option. The TLC Meter is excellent for saltwater intrusion monitoring, road salt studies, and for a general indication of contamination levels.
For More Info, email: email:
For More Info, email: email:
MANAGE YOUR
FACILITIES EFFECTIVELY
39521pr@reply-direct.com
For More Info, email: email:
For More Info, email: email:
Advanced Discrete Nutrient analysis
NH3, NO3, PO4, TKN, CL and more
Fast unattended Operation
For a nutrient analyser to suit your needs, call: +1 262-241-7900 email:
sales@seal-us.com or visit our website.
www.seal-analytical.com 6627ad@reply-direct.com
5697ad@reply-direct.com www.envirotech-online.com IET Annual Buyers’ Guide 2016/17
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108 |
Page 109 |
Page 110 |
Page 111 |
Page 112 |
Page 113 |
Page 114 |
Page 115 |
Page 116 |
Page 117 |
Page 118 |
Page 119 |
Page 120 |
Page 121 |
Page 122 |
Page 123 |
Page 124 |
Page 125 |
Page 126 |
Page 127 |
Page 128 |
Page 129 |
Page 130 |
Page 131 |
Page 132 |
Page 133 |
Page 134 |
Page 135 |
Page 136