18 Gas Detection MIT researchers develop a detector for continuously monitoring toxic gases
Most systems used to detect toxic gases in industrial or domestic settings can be used only once, or at best a few times. Now, researchers at MIT have developed a detector that could provide continuous monitoring for the presence of these gases, at low cost.
The new system combines two existing technologies, bringing them together in a way that preserves the advantages of each while avoiding their limitations. The team used a material called a metal-organic framework, or MOF, which is highly sensitive to tiny traces of gas but whose performance quickly degrades, and combined it with a polymer material that is highly durable and easier to process, but much less sensitive.
The results are reported today in the journal Advanced Materials, in a paper by MIT professors Aristide Gumyusenge, Mircea Dinca, Heather Kulik, and Jesus del Alamo, graduate student Heejung Roh, and postdocs Dong-Ha Kim, Yeongsu Cho, and Young-Moo Jo.
Highly porous and with large surface areas, MOFs come in a variety of compositions. Some can be insulators, but the ones used for this work are highly electrically conductive. With their sponge-like form, they are effective at capturing molecules of various gases, and the sizes of their pores can be tailored to make them selective for particular kinds of gases. “If you are using them as a sensor, you can recognize if the gas is there if it has an effect on the resistivity of the MOF,” says Gumyusenge, the paper’s senior author and the Merton C. Flemings Career Development Assistant Professor of Materials Science and Engineering.
The drawback for these materials’ use as detectors for gases is that they readily become saturated, and then can no longer detect and quantify new inputs. “That’s not what you want. You want to be able to detect and reuse,” Gumyusenge says. “So, we decided to use a polymer composite to achieve this reversibility.”
The team used a class of conductive polymers that Gumyusenge and his co-workers had previously shown can respond to gases without permanently binding to them. “The polymer, even though
it doesn’t have the high surface area that the MOFs do, will at least provide this recognize-and-release type of phenomenon,” he says.
The team combined the polymers in a liquid solution along with the MOF material in powdered form, and deposited the mixture on a substrate, where they dry into a uniform, thin coating. By combining the polymer, with its quick detection capability, and the more sensitive MOFs, in a one-to-one ratio, he says, “suddenly we get a sensor that has both the high sensitivity we get from the MOF and the reversibility that is enabled by the presence of the polymer.”
The material changes its electrical resistance when molecules of the gas are temporarily trapped in the material. These changes in resistance can be continuously monitored by simply attaching an ohmmeter to track the resistance over time. Gumyusenge and his students demonstrated the composite material’s ability to detect nitrogen dioxide, a toxic gas produced by many kinds of combustion, in a small lab-scale device. After 100 cycles of detection, the material was still maintaining its baseline performance within a margin of about 5 to 10 percent, demonstrating its long-term use potential.
In addition, this material has far greater sensitivity than most presently used detectors for nitrogen dioxide, the team reports. This gas is often detected after the use of stove ovens. And, with this gas recently linked to many asthma cases in the U.S., reliable detection in low concentrations is important. The team demonstrated that this new composite could detect, reversibly, the gas at concentrations as low as 2 parts per million.
While their demonstration was specifi cally aimed at nitrogen dioxide, Gumyusenge says, “we can defi nitely tailor the chemistry to target other volatile molecules,” as long as they are small polar analytes, “which tend to be most of the toxic gases.”
Besides being compatible with a simple hand-held detector or a smoke-alarm type of device, one advantage of the material is that the polymer allows it to be deposited as an extremely thin uniform fi lm, unlike regular MOFs, which are generally in an
ineffi cient powder form. Because the fi lms are so thin, there is little material needed and production material costs could be low; the processing methods could be typical of those used for industrial coating processes. “So, maybe the limiting factor will be scaling up the synthesis of the polymers, which we’ve been synthesizing in small amounts,” Gumyusenge says.
“The next steps will be to evaluate these in real-life settings,” he says. For example, the material could be applied as a coating on chimneys or exhaust pipes to continuously monitor gases through readings from an attached resistance monitoring device. In such settings, he says, “we need tests to check if we truly differentiate it from other potential contaminants that we might have overlooked in the lab setting. Let’s put the sensors out in real-world scenarios and see how they do.”
The work was supported by the MIT Climate and Sustainability Consortium (MCSC), the Abdul Latif Jameel Water and Food Systems Lab (J-WAFS) at MIT, and the U.S. Department of Energy.
Limit monitors to ensure rapid response to gas leak incidents enabling safety to both personnel and assets
For More Info, email: email:
LogiDataTech offer state-of-the-art free programmable, self-monitoring limit monitors of to evaluate the measurement signals of connected measuring systems, such as those used for toxic or explosive gases, oxygen, carbon dioxide, and temperature. When exceeding or falling below a specifi ed threshold, they trigger alarms or other downstream functions to alert the measurement system’s operator and enable a quick and effi cient response. Thanks to the monitors’ potential- free relay output, it is possible to activate devices, such as: magnetic valves, fans and acoustic transmitters in response to an alarmed incident.
For More Info, email: email:
Different sensors can be connected to a limit monitor via 4 - 20 mA interfaces. LogiDataTech offer several connectable measuring systems: The compact, wall- mounted GWZ-S2.1 and GWZ-S4.1 limit monitors have a plastic housing for wall mounting; they are designed for connection of max. 4 probes on 4 - 20 mA inputs. The GWZ-TS4.1 and GWZ-TS6.1 models have a plastic housing for DIN rail mounting (TS35). They are designed for connection of max. 6 probes on 4 - 20 mA inputs. The freely programmable, self- regulating limit monitors are used for indicating the concentration of gases and vapours. Up to 6 LogiDataTech sensors can be connected to the 4 - 20 mA interface. The sensors are supplied via this device with 24 V DC. There is also a digital input so operators can wire a digital signal contact (e.g. pressure, water level) and a digital input for the external horn reset.
For More Info, email: email:
Looking to Grow Your Company’s Product Sales Portfolio?
Are you a Distributor with a proven track record in selling gas
detection, laboratory or safety products? Are you looking for a quality range to enhance your sales portfolio?
Euro-Gas are currently searching for Companies in the UK and across Europe to distribute the pioneering and world-leading Komyo Kitagawa Gas Detector Tube System and range of gas detector accessories.
We offer full training, support and marketing assistance for all our Distributor Network members. Please get in touch for information. We look forward to meeting you!
These devices self-monitor the wiring of the sensor. It detects wire break and short circuit while triggering a fault message. The malfunction alarm relay is designed fail-safe, means, in case of failure power supply is cut off (closed-circuit principle) and a power failure can thus be detected.
The limit monitors have 4 potential-free relay outputs. The alarm relay contacts alert the operator when threshold limits are exceeding or fall short of the set threshold limits. For example, they can visually and acoustically trigger pre and main alarm or start-and turn off a fan. The alarm outputs are available with hysteresis, latching or latching prematurely acknowledged. The alarm relay can be assigned a time function (minimum pulse time, maximum pulse time, delayed on/off).
The other relays are a relay to control a horn, a fault alarm relay so operators are aware of cable breaks, short circuits, and electronic failures, while the fault message relay system displays malfunctions. Finally, a test function allows the verifi cation of the output relay.
More information online:
ilmt.co/PL/kA8d For More Info, email:
email:
Churston House, Bascombe Road, Churston Ferrers, Devon, TQ5 0JJ, United Kingdom.
☎ +44 (0)1803 844414
Email:
sales@euro-gasman.com Web:
www.euro-gasman.com
For More Info, email: email:
For More Info, email: email:
IET ANNUAL BUYERS’ GUIDE 2024/25
If you wish to submit an article for possible inclusion in International Environmental Technology
or on Envirotech-online, please contact David Phillips.
david@envirotechpubs.com
62366pr@reply-direct.com
63021pr@reply-direct.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108