Water/Wastewater
Process Refractometer is a New and Economical Way to Monitor TOC in Effluent
Excess organics or excessive Total Organic Carbon (TOC) content, e.g. alcohols, proteins, sugars, fats, etc. in various wastewater streams in the corn sweetener and beer brewing industries can incur fines and penalties. In severe cases the plant can even be closed.
As these effluent streams typically contain high levels of TOC (up to 10,000 PPM) the Refractive Index technique that K-Patents’ refractometer is based on, has proven to be a very successful measurement method for this purpose.
Ion exchange is a filtration process aimed at removing soluble ionised substances. For the purposes, ion exchange resins in columns are used in industrial plants.
The solution to be treated, e.g. sugar solution, flows through the resin in the exchanger column. As there are cations and anions in the solution, two different types of resins must be used: a cation exchanger and an anion exchanger. The cation resin is used in the hydrogen form (H +), thus, it must be regenerated with an acid, in this case, with a strong Hydrochloric acid HCl. HCl controls the pH of process water streams providing water purity, demineralises water and rinses cations from the resins. The cation resin removes hardness from water since it is also alkaline.
The anion resin is used in hydroxyl form (OH -), thus, it must be regenerated with a strong alkali NaOH. Alkaline environment softens the solution by removing strong acids.
This combined arrangement produces pure solution. After the solution has been demineralised, sugar can be removed from the process, and produced in the process sweet water forwarded to the storage tank.
TOC has traditionally been measured both on- and off-line. Conductivity and non-dispersive infrared (NDIR) are the two common detection methods used in on-line TOC analysers. These analysers are expensive to maintain and calibrate, and there can be frequent breakdowns in their operation.
Laboratory off-line samples and testing are used to confirm the TOC analyser readings. However, if the sampling frequency for the laboratory analysis is too small, potential TOC excursions can be missed.
To control the effluent effectively and provide the wastewater treatment plant with warning of exceptional loads, the measuring instrument used must be reliable and remain in-line at all times. K-Patents refractometer provides reliable in-line real-time measurement of the dissolved solids before the sewage proceeds to the treatment plant. Wastewater treatment plant knows about the incoming TOC and can keep treatment process in proper operation and compliance.
K-Patents process refractometers provide reliable measurement for alarming of incoming dissolved solids (indication of high organics). For instance, alarms can be set at 6,500 PPM and the pump shut-off at 7,500 PPM.
K-Patents Teflon Body Refractometer PR-23-M provides in-line measurements of the effluent sewer at its dispersing outlet to the treatment plant. The refractometer can read 0-1% total dissolved solids that correlate with 0-10,000 PPM TOC scale.
For over 30 years, K-Patents (Finland), has been specialising in in-line liquid concentration measurement instruments for industrial users and OEMs in the chemical, oil and petrochemical, pulp and paper, food, semiconductor and pharmaceutical industries.
For More Info, email:
25100pr@reply-direct.com Introduce a Surfactant Electrode
COMBINATION IONIC SURFACTANT PROBE
Salient Points:
1) Suitable for both anionic and cationic surfactant measurements
New DIN Panel Mount Indicators bring Unique Features
Fluidwell (Netherlands) celebrates its 20th anniversary with the launching of an exciting new line of products: The new D Series. An extensive selection of DIN panel mount indicators and controllers for liquid and gas applications for flow, level, pressure and temperature measurement in industrial environments. In addition to simplicity and user-friendliness, which are already key features of Fluidwell’s F-Series, the D Series brings a unique feature in DIN panel mount indicators: Its IP66, IP67 (NEMA4X) enclosure. Even total immersion is not an issue.
“The greatest advantage of this new DIN panel mount indicator is its unique waterproof qualities”, says Eric Rath, General Manager of the Fluidwell Group in The Netherlands. “The robust IP66, IP67 and NEMA4X type enclosure withstands extreme weather conditions,
powerful water jets and even total immersion. It saves lots of time and cost. For instance it is perfect for cleaning and wash-down applications without worrying about water damage.”
Fluidwell F-Series users already appreciate the simple, logical menu-driven structure, with alphanumerical descriptions of settings instead of confusing abbreviations and difficult codes. It saves significant time and cost in installation and programming. “The D-Series is in no way different. Those familiar with an F-Series unit, can also program and install any D-Series unit without the use of the manual or hiring technical experts. It is truly: know one, know them all!”, Eric adds.
The D-series does not require special maintenance other than a periodic check of the casing and wiring. The long life lithium battery and special power saving options lead to a battery life time of up to 7 years. This saves considerably on maintenance cost. And with its minimal depth clearance of just a few inches, the D-Series is a great solution for smaller, low-cost panels and panel doors.
As Eric Rath puts it: “It took us many years of designing and redesigning before we were satisfied with the results, but it was worth it all: It’s simply the better alternative”.
The new D-Series is available as indicator, totaliser, batch controller, transmitter and monitoring system for flow, level, pressure and temperature measurement in safe area applications. It comes in multiple combination possibilities for sensor in- and outputs and power and sensor supply, with much more to come in the near future.
For More Info, email:
25092pr@reply-direct.com email:
35ad@reply-direct.com
www.envirotech-online.com IET Annual Buyers Guide 2013
2) Both combination probe and a Mono are available (mono requires double junction reference probe)
29
Contact Sales Department at:
SENTEK LIMITED, Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE. Tel: +44 (0) 1376 340 456 Fax: +44 (0) 1376 340 453 Email:
sentekuk@btconnect.com
For further information email:
73ad@reply-direct.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108 |
Page 109 |
Page 110 |
Page 111 |
Page 112 |
Page 113 |
Page 114 |
Page 115 |
Page 116 |
Page 117 |
Page 118 |
Page 119 |
Page 120 |
Page 121 |
Page 122 |
Page 123 |
Page 124 |
Page 125 |
Page 126 |
Page 127 |
Page 128 |
Page 129 |
Page 130 |
Page 131 |
Page 132 |
Page 133 |
Page 134 |
Page 135 |
Page 136