search.noResults

search.searching

saml.title
dataCollection.invalidEmail
note.createNoteMessage

search.noResults

search.searching

orderForm.title

orderForm.productCode
orderForm.description
orderForm.quantity
orderForm.itemPrice
orderForm.price
orderForm.totalPrice
orderForm.deliveryDetails.billingAddress
orderForm.deliveryDetails.deliveryAddress
orderForm.noItems
ADVERTORIAL


0


An Experience of Innovation Where Quality meets Efficiency


The new CellGard NU-480 Laminar Flow Class II,Biological Safety Cabinet features the unique TOUCHLINK Electronic Airflow Control System that monitors and controls all cabinet functions. The control system is a self- contained micro-processor module that performs the following functions: Controls blower motor; monitors, displays and controls interior downflow and inflow velocities; monitors for high or low airflow alarm conditions; real time clock display and timer functions; controls lights and outlets; control system automatically compensates for filter loading; voltage variances and other environmental effects; remote contact outputs for interaction with HVAC systems, energy saving night setback mode, window, ultraviolet light, and auxiliary alarms; optional chart recorder outputs; and complete diagnostic functions.


The NU-480 has several new ergonomically designed features for user comfort and adjustability to eliminate awkward posture, the service valves have been staggered on the sidewalls making them easily accessible, relieving arm, neck and shoulder strain, frameless polished edge windows offering greater visibility, better sight lines, reducing eye fatigue. Ergonomic Chair, Footrest, and Motorised Base Stands to raise or lower the work surface within an eight inch range to alleviate bodily strain and increase safety conditions for laboratory professionals.


The NU-480 has an exclusive Auto Decontamination Cycle, Decon 101. The 10-degree sloped window ensures that the work area is completely sealed during this process. The TOUCHLINK system provides step-step instructions to aid in proper Decon techniques.


Circle no. 212


Experience Constant Contamination Control (C3)


NuAire’s CO2 AutoFlow Incubators offer the highest level of performance and dependability for optimum cell growth conditions.


The DHD AutoFlow NU-5510 CO2 incubator utilises a digital, solid-state programmable microprocessor


infrared [IR] CO2 sensor; dual temperature sensor probes; and various status alarms that make necessary


corrections to the chamber environment supporting chamber uniformity and quicker recovery times.


The interior chamber walls are lined with high tech R5 insulation for temperature stability and energy efficiency. Every AutoFlow incubator utilises a 99.99% HEPA filtration system ensuring a Class 100 air quality inside the work chamber.


The interior chamber is maintained at a positive pressure similar to an ISO Class 5 Cleanroom. AutoFlow offers a smaller footprint with largest amount of usable interior space (6.65 ft3). Dual sterilisation cycles, 95°C humidified or 145°C dry, are useful for cell line changes or when working with hazardous agents.


Circle no. 213


Controlled Environments for Optimum Storage Conditions NuAire’s®


Glacier™ -86°C Ultralow Temperature


Freezers provides laboratory professionals a safe, reliable freezer that they can depend on.


Each freezer is designed with the most advanced features available for research, clinical and industrial applications, providing the best value found in an ultralow freezer.


Glacier’s non-flammable CFC – free refrigerants, insulation system is able to withstand extremely low temperatures; the multi-point gasket seal, heated door seals and insulated inner doors minimise the potential for frost build up.


The technologically advanced compressor that Glacier employs ensures low power consumption, as well as uniform temperature stability. Utilising an electronic microprocessor control with automated back-up and alarm systems ensure accuracy and reliability.


Constructed of heavy-gauge cold-rolled steel, conducts temperature more efficiently than stainless steel, creating less stress on compressors making them run cooler, last longer, easy to maintain and less costly with a quiet 47 dba operation.


Where Quality Meets Efficiency: http://www.nuaire.com/products/biological _safety_cabinets/cellgard_480/features.htm


Experience Constant Contaminationcontrol


www.nuaire.com/products/co2 _incubators/autoflow _5510/features.htm


Controlled Environments for Optimum Storage Conditions:


http://www.nuaire.com/products/ ultralow_freezers.htm


Circle no. 214 Circle no. 215


INTERNATIONAL LABMATE - APRIL/MAY 2010 - ADVERTORIAL


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68