approximately 7km tunnel and about 550m of pipejacked connections. Following consultation with industry experts and comparison with recent similar-sized projects, the internal diameter was increased from 2.85m to a minimum of 3.5m ID. There were 13No shafts of varying diameters proposed, ranging from 6m ID reception shafts for the pipejack connections to larger launch and rotation shafts for the bored tunnel (between 9m and 15m ID). Tunnel depths would vary between 15m and 40m below ground level. The advantages of the bored tunnel approach included
the ability to follow sweeping alignments, avoid congested areas, increase network storage capacity, and provide excellent control over ground movements. However, the complexity and cost of the solution encouraged the team to examine potential alternatives.
Pipejacking alternative A significant portion of Max’s part of the presentation focused on the development of a pipejacking alternative, making use of PJA guidance and other industry standards. Several factors motivated this investigation. Budget
constraints were an important consideration, and from a hydraulic perspective there was no requirement for such large tunnel diameters. Pipejacking offered the possibility of achieving sufficient hydraulic performance while reducing project cost and potentially shortening programme durations. Machine availability and flexibility in connecting to problem locations were additional advantages. The pipejack option followed many of the same route
selection principles as the bored tunnel. However, the design team had to account for more restrictive bend radii and alignment limitations. This generally resulted in a greater number of shafts being required. Despite this, the drives could often follow more direct routes. The final pipejack concept consisted of approx. 7.8km
of pipejacked drives with 1.5m-2.4m pipe diameters, plus 17No shafts of 6m ID and 12.5m ID. The comparative assessment demonstrated several
important benefits. The pipejack solution achieved similar hydraulic performance while delivering substantial cost reductions. The embodied carbon assessment also indicated lower carbon emissions compared with the bored tunnel option. Overall project construction costs were estimated to reduce by approximately 35%. Ground movement analysis suggested that settlement
levels associated with the pipejacked solution remained within acceptable limits for buildings/structures, largely because the drives were relatively deep, reducing impact at surface. While the bored tunnel offered superior control in highly sensitive locations, the pipejack solution remained technically viable across the majority of the network. It was concluded that modern increases in achievable
pipejack drive lengths have significantly expanded the applicability of the technique. As a result, pipejacking can now represent a genuine alternative to traditionally larger tunnel schemes.
Small-Scale Trenchless Interventions Matthew then shifted the focus towards smaller-scale trenchless interventions and the detailed optioneering
process used to identify opportunities throughout the town. His role was specifically to identify locations where microtunnelling, pipejacking and other trenchless techniques could reduce disruption while delivering targeted performance improvements. These interventions formed part of a wider suite of solutions that included sewer upsizing, storage provision, and surface water separation. One of the most important principles described was the close collaboration between hydraulic modellers and civil designers. Every proposed intervention was tested within hydraulic models to understand both local benefits and wider network impacts. This led to an iterative process in which ideas were regularly developed, tested, modified, or discarded based on modelling results. The process enabled the team to move rapidly
through large numbers of potential solutions while ensuring engineering decisions remained driven by network performance. Weekly feedback loops between disciplines allowed the team to continuously refine their understanding of viable options.
Site Selection Challenges One of the most interesting aspects of the presentation related to the extensive site selection exercise carried out across Shrewsbury. The town has approximately 90,000 residents and contains more than 650 Listed Buildings within a conservation area. Historic landmarks include the castle, abbey, prison, medieval street network, and numerous heritage structures. This created significant challenges when attempting to identify suitable sites for compounds, shafts, and construction activities. The team established a long list of potential sites and
assessed them against multiple criteria including: ● Available space ● Construction access ● Flood risk ● Network connectivity ● Topography ● Nearby structures ● Stakeholder impacts ● Heritage considerations
November 2026 | 29
Above: Pipejack option - layout of drives and shafts.
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45