SOFT GROUND – HS2 PROPLESS OPENINGS - BTS MEETING | TECHNICAL
Far left: Cast special
segment showing openings for dowels and rods.
Left: Ring build with special segments,
showing dowels and rods.
performance into one solution, Xavier explained. It would have to be able to work under high and variable loads and ground conditions, considering both temporary loads during excavation (possibly with artificial ground freezing (AGF)) as well as long-term loading during the operational lifetime. Upon reviewing the state of the art, the conventional
solutions included internal removable frames, permanent steel frames around openings, or combinations of propping and collars. But on NTW, given the soil conditions and relatively high loads, such standard solutions could not meet the construction team’s requirements to avoid propping and have a single support system. Xavier said the design and construction teams
developed a new support system that would be reliable and flexible, while also satisfying durability, fire resistance and watertightness requirements for the various opening sizes. The structure has a 120-year design life.
Innovation Xavier said the underlying structural problem is straightforward to describe but it was difficult to solve. A circular segmental tunnel lining behaves well as a closed ring. When an opening is created, the hoop forces around the ring must be redistributed, bridging around that gap to transfer to the adjacent segments and rings, which results in localised high section forces in sections as well as tension forces close to the opening. It is preferable that several rings should be bonded
together to perform more like a jointless pipe. In such a pipe the load can redistribute more effectively around the opening. To do this the joints would need to be connected, increasing the tube’s stiffness and so preventing individual segment deformations and steppings. The design solution was to use combinations of shear dowels (to connect adjacent segments and prevent radial dislocations), embedded steel profiles (inside the special segments to distribute the large local dowel loads into the concrete, and prevent punching damage) and prestressing rods (to provide stiffness, temporarily during construction).
Modelling For modelling there was a split approach with separate models for geotechnical and structural analyses – the former looking at load derivation from the ground, which inputs to the latter model and helped with design checks. For load derivations we used models to consider two extreme cases: fully connected joints, comparable to
a continuous pipe (no ring joints); and open joints and a more disconnected (flexible) set of rings. These two cases provided upper and lower bounds for the possible ground loading. These geotechnical models considered the ground conditions, construction staging, short-term conditions and long-term conditions. From those models we obtained design derivations that were then fed into structural models. The geotechnical modelling software used was PLAXIS 3D. The structural models were different because they
would focus on the particular connection between rings and their non-linear load deflection behaviour. They also considered different stages of sequential excavation and lining installation. The process was iterative: the geotechnical models gave bounding cases, and the structural models then represented the actual behaviour of the special segments, dowels, prestressing rods and embedded steel components. There was therefore calibration between the models. The design had to accommodate temporary
loads during excavation and permanent loads after completion. It also had to account for the practical tolerances required to assemble the segments and their connectors reliably during TBM construction. The structural modelling software used was SAP2000. The special segments also include a dense rebar cage
and a higher concrete grade, around C70. The key idea is to transfer complexity of works
away from activities in the tunnel and instead into the precasting factory. The steel elements, tolerances and connection details are dealt with under factory conditions where quality control is easier. Later, inside the TBM and tunnel, the elements are aimed to fit together precisely and smoothly, and the use of the standardised system should ease the installation routine. The design process began in February 2018 and
moved through detailed design towards approval in April November 2026 | 13
Below: Close-up view of special segment during ring erection.
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45