CERTIFIED CEMS & PROCESS ANALYSERS EMISSIONS & PROCESS MONITORING
MCS100FT CEMS: Continuous emissions monitoring of all pollutant components in exhaust gases
With the MCS100FT, SICK offers an FTIR analyzer system that provides complete, continuous emissions monitoring. It detects more than 12 measuring components simultaneously, such as HF, HCl, SO2, NO, NO2, CO, NH3, N2O, CH4, and Corg (VOC). The MCS100FT enables HF limit values to be monitored in accordance with legal requirements. It is equipped with an oxygen sensor as standard and can be supplemented with an integrated total hydrocarbon analyzer (FID).
MERCEM300Z extractive gas analyzer: Monitoring mercury in emissions
The MERCEM300Z extractive gas analyzer has one of the smallest certified measuring range of all measuring systems suitability tested in accordance with EN 15267-3, with a range from 0 to 10 μg/m³ total mercury content. It is also suitable for continuously monitoring the annual threshold of 10 μg/m³. The greatest advantage of the MERCEM300Z is that it transforms oxidized mercury into elemental mercury without the addition of chemicals or converters. This significantly reduces the amount of maintenance required in comparison to all other measuring systems.
Combiprobe CP100 CEMS solution: Space-saving solution for measuring dust, flow, pressure, and temperature
With the CP100 combiprobe, dust, flow, pressure, and temperature can be measured in the stack with minimal use of space. This solution involves installing a DUSTHUNTER SP100 (scattered light method), a FLOWSIC100 PR (ultrasonic measuring principle as a probe), and a PT100 temperature sensor and pressure sensor on a combination flange (DN250 PN6). This renders additional couplings or flanges unnecessary. This space- saving solution especially proves its worth where redundant design of the measuring devices is required.
MCS300P HW process solution: Process measurement at flue gas scrubber inlets
In the flue gas scrubber, among others, HCI and SO2 are reduced with reagents. Activated carbon is added for mercury removal. The MCS300P HW simultaneously measures the SO2, HCI, H2O, and optionally the O2. The MCS300P is an extractive process photometer which can measure gaseous or liquid media. It measures IR and VIS active components with variable measuring ranges available, capable of automatic sample point switch and an integrated adjustment unit the MCS300P also has flexible I/O capabilities for interfacing with the plants DCS.
ZIRKOR200 in-situ gas analyzer : Monitoring incineration efficiency (O2)
The ZIRKOR200 in-situ gas analyzer is used to measure O2. It quickly, reliably, and continuously measures the oxygen concentration during incineration. This allows optimal regulation of oxygenation from primary and secondary air, achieving permanent monitoring for the purposes of combustion optimization.
www.sick.co.uk
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108