Laboratory Products 39 Economical Recirculator Provides Low-Cost Cooling for Laboratory Applications


An efficient and reliable liquid-to-air recirculator that provides exceptionally economical heat removal for FTIR, GC/MS, ICP, vessels, and other laboratory applications is now available from PolyScience. Intended for removing heat loads from sensitive equipment and processes, the Model 3370 Liquid-to-Air Cooler boasts a 4000 watt cooling capacity at 20°C (68°F) and can handle liquid temperatures as high as 70°C (158°F). As a result, it offers significant cost-savings over mechanically refrigerated circulators.


Designed for simple operation and maintenance, the Model 3370 circulates fluid at up to 20.5 lpm (5.4 gpm) to the equipment, back into a reservoir, and through a fan-cooled radiator which removes heat. A built-in low-liquid level indicator safeguards the reservoir and circulation system. The pump and cooling system are further protected with reusable filters. The unit is available with either a turbine or positive displacement pump.


In addition to long life and easy maintenance, the Model 3370 Liquid-to-Air Cooler is also extremely compact. Measuring just 20.5 x 15 x 22.3 inches (52 x 38.1 x 54.6 cm), it requires only slightly more than 1.5ft2 of floor or bench space.


For more information visit www.polyscience.com. 38345pr@reply-direct.com


Automatic Hydraulic Laboratory Press Series Showcasing at Pittcon 2018


Carver, Inc will be featuring its Auto Series Plus automatic hydraulic laboratory press at Pittcon 2018 in Booth No. 3453. The Auto Series Plus features a large 7” colour operator interface, enhanced platen temperature control and auto-tuning, ramp heating capability, real-time trending of force and temperature and seven-day timer for auto heat-up. Other features include storage of up to 250 recipes, recipe preview and optional data logging for cycle parameters.


Auto Series Plus press models are available with 15 to 48 tons of clamping force and 6” x 6” to 19” x 19” platens. These benchtop presses are used in quality control and research and development for test sample preparations, destructive testing, moulding, laminating and fluid extraction.


Carver is a leading manufacturer and supplier of standard and custom hydraulic presses for laboratory applications such as pelletizing, lab testing, pharmaceuticals, liquid extraction, cell disruption, laminating, specimen preparation and other applications.


Carver’s full line of two-column and four column benchtop, floor standing, manual, automatic, pneumatic and hydraulic presses offer clamping capacities from .5 to 150 tons. Carver also offers a wide variety of laboratory accessories for applications in IR, XRF, pharmaceutical, oil extraction, proppant crush testing, colour dispersion and more.


44924pr@reply-direct.com ADVERTORIAL New Automatic KF Moisture Meter CA-310 Released


KF Moisture Meter CA-310 from Mitsubishi Chemical Analytech is a new model change to CA-200/KF-200, which has been supported by numerous users over many years. The instrument offers enhanced


performance, scalability and operability and is equipped with an 8.4 inch colour LCD touch panel.


KF Moisture Meters is a distinct wet chemistry analysis method. With increasing regulatory efforts, the number of laboratories implementing GMP/GLP compliance or similar quality assurance is growing. Many current solutions require the use of a PC to operate the analyser to assure data integrity and traceability. With its newly designed Multi Controller, Mitsubishi Chemical Analytech provides its model CA-310 with data integrity features for an audit trail at the point of data generation.


Whilst all the data is handled securely and stored locally, it is still available on the network for further processing. With its modular concept, the CA-310 is able to be scaled from one to four titration channels, all of which can further be equipped with auto sample changer or other vaporisers.


CA-310 is equipped with a high level of automation, from automatic start up to shut down including connected accessories, cell dehydration, vaporiser heating, carrier gas valve switching, gas flow control. CA-310 recognises the exchange timing of reagent by automatic EVAC unit, which can realise full automation together with auto sample changer VA-236S.


Mitsubishi Chemical Analytech is a unique company which is supplies both Moisture Meters and reagents. For many years, Mitsubishi Chemical Aquamicron reagents have provided a number of application databases for choosing the best reagent and instrument settings. Peak performance has now been reached with the integration of Aquamicron reagents into the CA-310 system, thus enabling barcode input of reagent data, such as, shelf life, LOT number or certified values directly and without errors. Together with reagent lifetime control and automatic exchange, it allows keeping the highest level of measurement performance over a long period of time.


World-leading KF Moisture Meter CA-310 surely presents the best solution to overcome various challenges in your industry.


44154pr@reply-direct.com Untitled-16 1 8360ad@reply-direct.com 16/10/2017 11:02


WWW.LABMATE-ONLINE.COM


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92