NEWS


filtra Camfi


S


Camfil welcomes new particle filt


ation st fil welc


ti t


ince 01 June, the international standard f or particle filtration in buildings – ISO 1 6890:2016 – has replaced previous test s tandards. According to Peter Dyment, UK


t echnical manager at Camfil, this new standard was necessary and timely because of the increased need to protect people against city air pollution. Mr Dyment said: “BS EN ISO 16890:2016 will t ransparently inform filter users of the filter e fficiency compared to its predecessors (EN 779 in E urope and ASHRAE standard 52.2 in the US). In June 2018, EN779:2012 will be withdrawn, leaving ISO 16890:2016 as the current standard. The ASHRAE standard is also due to be replaced by the ISO standard in the near future.”


The ISO standard defines testing procedures and gives a classification system for air filters in general v entilation equipment. The classification system is related to filter performance against three different particle size ranges (PM1, PM2.5 and PM10). Mr Dyment explained: “For the first time, in ISO 16890:2016 we have an air filtration standard that


andard omes n


d d


actually tells people specifically what a filter does. “ For example, a typical air filter of a class t hat is going to make a difference to indoor air q uality is defined in the new standard as ‘ePM1 6 0% minimum’ where ‘e’ stands for the removal efficiency of the filter, PM1 is the range of particles (=/< 1µm in size), and 60% is the percentage of particles the filter will remove.


“ Under the old European standard – EN 779:2012 – the equivalent filter would have been designated ‘ F7’ which doesn’t tell consulting engineers, designers and specifiers what the filter is capable of.”


Furthermore, test procedures for ISO 16890:2016 are more closely aligned to ‘real-world’ filter p erformance, said Mr Dyment. The performance t olerance of the new standard is also set much t ighter at 5%.


He added: “Because it is due to replace two competing standards from Europe and the US, ISO 16890:2016 also represents the first opportunity for global harmonisation in testing procedures


and a classification system for air filters used in ventilation equipment.”


Particulate matter (PM) affects more people than any other airborne pollutant. PM consists of a complex mixture of solid and liquid particles of organic and inorganic substances suspended in the air. Its major components are sulphate, nitrates, ammonia, sodium chloride, black carbon, mineral dust and water.


PM10 is the fraction of all airborne particles =/< 1 0 microns (µm) in size, while PM2.5 is the fraction of all airborne particles =/< 2.5µm in size and PM1 is the fraction of all airborne particles =/< 1µm in size (1µm = 1/1000th of a millimetre).


Humans with a sedentary lifestyle typically breathe 15kg of air each day. In highly polluted areas, we breathe more than 25 million particles w ith each breath.


Mr Dyment concluded: “Using PM1 class filters t o a high efficiency rating are best way to protect building occupants in city locations. PM1 could also stand for People Matter 1st.”


Sigma is VRF with flexibility built in


With its new Sigma-shaped heat exchanger, the Set Free Sigma VRF range is high efficiency even at low or partial load in cooling mode, achieving SEER up to 8.33 and a market- leading SCOP of up to 5.06.


  5HP to 24HP in a single unit module up to 96HP with combinations


  Two pipe heat pump, three pipe heat recovery


  Off coil temperature control eliminates cold draughts


  apanese technology


 Japanese technology,, manufactured in Europe


To find out more call l Hitachi on 020 3901 0912 @hitachiairconUK


Hi hitachi-hvac.com 7 NEW Hitachi


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64