SPONSORED FEATURE  Cover story P


ageant is an intrinsically safe Operator Panel comprising a seven inch backlit display, PLC and I/O modules for use in gas and dust hazardous areas. It provides the advantages of intrinsic safety, plus lower power dissipation, less weight and lower cost compared with systems employing alternative explosion protection techniques. This new integrated panel, which is internationally Ex ia certified for installation in all gas and dust Zones, has plug-in I/O modules and is able to display multiple variables and graphics in all lighting conditions. Ideal for monitoring and controlling hazardous area equipment and processes, Pageant employs the well established IEC 61131 compliant, CODESYS® runtime PLC software and visualization engine which has become an industry standard, and is now used in more than 1,500 different products worldwide. It will therefore already be familiar to many users. Pageant is supplied with a lifetime software licence and a three year guarantee plus extensive documentation. The Pageant Operator Display incorporates eight touch buttons each with a tricolour LED annunciator for operator inputs, all of which are individually programmable. Two additional LEDs indicate status and diagnostics. Operator inputs can also be made via a plug-in digital input module from external contacts such as large industrial push buttons.


Applications range from a simple remote Modbus RTU terminal displaying multiple variables, to more complex systems such as the control and display of mixing, batching, trace heating, mud pumping or flammable still control, in any hazardous location, and with almost any gas or dust. Pageant can function alone, or as part of an intrinsically safe RS485- IS network, including operation as a Modbus RTU master or slave. To simplify design and further reduce cost,


Pageant is modular. The Operator Panel accommodates any combination of up to seven individually certified plug-in analogue and digital I/O modules, which can be connected to apparatus in Zone 0, 1, 2, 20, 21 or 22. Only the required modules need to be purchased, and if process requirements change, additional modules may be fitted and commissioned on-site, all without the need for additional certification. The flexible IECEx, ATEX and UKEX certification allows any combination of BEKA plug-in I/O modules to be fitted to the display without additional approval. Similarly flexible North American certification is pending. Pageant consumes less than four watts and is powered by a BEKA Power Isolator located in a safe area, or with additional impact and environmental protection in Zone 2 or 22. The very low power consumption minimises heating when Pageant is installed in an electrical control enclosure or cubicle, and the low weight permits installation in a cabinet door.


8


MEET PAGEANT THE ZONE 1 INTRINSICALLY SAFE OPERATOR PANEL


PAGEANT FEATURES:


7 inch backlit monochrome display readable in bright sunlight


8 programmable touch buttons with tricolour annunciators


Modular design - any combination of the following plug-in modules may be fitted: 4 x 4/20mA individually isolated inputs 8 x contact inputs


8 x proximity detector inputs 4 x 4/20mA individually isolated outputs 4 x solid state contact outputs 2 x totaliser or counter inputs


IECEx, ATEX and UKEX Ex ia certification - North American certification pending


IEC 61131 compliant CODESYS runtime PLC software


Inputs polled and outputs updated 10 times per second


Optional isolated RS485-IS port


Can function as a Modbus RTU master or slave


For many


hazardous area control and display applications


requiring multiple variables and simple graphics, Pageant can be tailored to provide an easy to use low cost solution.


Visit the BEKA website at www.beka.co.uk and read ‘Pageant Explained’ to see what Pageant could do for you, or better still, request a demonstration at your site, or at BEKA in Hitchin where Pageant was designed and is being manufactured. A Pageant system can be as simple or as complicated as you wish it to be.


BEKA associates Ltd sales@beka.co.uk


www.beka.co.uk 01462 438301


September 2023 Instrumentation Monthly


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102